Thermoluminescence dosimetry of model line sources containing vanadium-48
Publication type: Journal Article
Publication date: 2005-10-01
scimago Q2
wos Q1
SJR: 0.372
CiteScore: 2.8
Impact factor: 2.2
ISSN: 13504487, 18790925
Instrumentation
Radiation
Abstract
Among several types of sources used or suggested for intravascular brachytherapy (IVBT) an interesting proposition is a positron–gamma emitter, vanadium 48 V ( E max , β + 0.7 MeV, t 1 / 2 = 15.97 d), which can be produced by proton or deuteron activation of ready-to-use titanium-rich stents. Accurate mapping of doses delivered by IVBT sources is essential. In this work, dosimetry of model line sources containing 48 V was performed by means of the thermoluminescence method, aiming at high spatial resolution. The sources were made of 0.25 mm titanium wire activated with 17 MeV protons in the AIC-144 cyclotron. The radial dose distribution was measured using a batch of sandwich detectors of 2 mm diameter, with 0.05 mm MCP (LiF:Mg,Cu,P) radiation-sensitive layer. The 2-D dose distribution was mapped with a batch of large-area sintered MCP detectors of 19 mm diameter, which were further scanned on a protype 2-D thermoluminescent reader equipped with a CCD camera. Spatial resolution of both types of the detectors was sufficient to reveal anisotropies of the sources. The results were in accordance with earlier dosimetric data concerning stent-based 48 V sources. Applicability of the new detectors in mapping doses delivered by line sources is discussed.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
3
|
|
|
Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms
3 publications, 37.5%
|
|
|
Applied Radiation and Isotopes
3 publications, 37.5%
|
|
|
Journal of Physics: Conference Series
1 publication, 12.5%
|
|
|
Cochrane Database of Systematic Reviews
1 publication, 12.5%
|
|
|
1
2
3
|
Publishers
|
1
2
3
4
5
6
|
|
|
Elsevier
6 publications, 75%
|
|
|
IOP Publishing
1 publication, 12.5%
|
|
|
Wiley
1 publication, 12.5%
|
|
|
1
2
3
4
5
6
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
8
Total citations:
8
Citations from 2024:
0
The most citing journal
Citations in journal:
3
Cite this
GOST |
RIS |
BibTex |
MLA
Cite this
GOST
Copy
Rorat E. et al. Thermoluminescence dosimetry of model line sources containing vanadium-48 // Radiation Measurements. 2005. Vol. 39. No. 5. pp. 495-501.
GOST all authors (up to 50)
Copy
Rorat E., Petelenz B., Marczewska B., Ochab E. Thermoluminescence dosimetry of model line sources containing vanadium-48 // Radiation Measurements. 2005. Vol. 39. No. 5. pp. 495-501.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.radmeas.2004.09.008
UR - https://doi.org/10.1016/j.radmeas.2004.09.008
TI - Thermoluminescence dosimetry of model line sources containing vanadium-48
T2 - Radiation Measurements
AU - Rorat, Elżbieta
AU - Petelenz, Barbara
AU - Marczewska, Barbara
AU - Ochab, Ewa
PY - 2005
DA - 2005/10/01
PB - Elsevier
SP - 495-501
IS - 5
VL - 39
SN - 1350-4487
SN - 1879-0925
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2005_Rorat,
author = {Elżbieta Rorat and Barbara Petelenz and Barbara Marczewska and Ewa Ochab},
title = {Thermoluminescence dosimetry of model line sources containing vanadium-48},
journal = {Radiation Measurements},
year = {2005},
volume = {39},
publisher = {Elsevier},
month = {oct},
url = {https://doi.org/10.1016/j.radmeas.2004.09.008},
number = {5},
pages = {495--501},
doi = {10.1016/j.radmeas.2004.09.008}
}
Cite this
MLA
Copy
Rorat, Elżbieta, et al. “Thermoluminescence dosimetry of model line sources containing vanadium-48.” Radiation Measurements, vol. 39, no. 5, Oct. 2005, pp. 495-501. https://doi.org/10.1016/j.radmeas.2004.09.008.