Sensors and Actuators, B: Chemical, volume 331, pages 129398
Composable paper-based analytical devices for determination of flavonoids
Publication type: Journal Article
Publication date: 2021-03-01
Journal:
Sensors and Actuators, B: Chemical
Quartile SCImago
Q1
Quartile WOS
Q1
Impact factor: 8.4
ISSN: 09254005
Materials Chemistry
Metals and Alloys
Surfaces, Coatings and Films
Electronic, Optical and Magnetic Materials
Condensed Matter Physics
Electrical and Electronic Engineering
Instrumentation
Abstract
Abstract A concept of composable paper-based analytical devices (composable μPADs) is proposed. The key idea of composable μPADs is to develop a paper-based analytical platform that can be easily and quickly assembled into a desired architecture from standard pre-made paper-based parts. Here it is illustrated by the determination of several flavonoids, as an important class of natural polyphenol antioxidants. Two methods for the determination of flavonoids, at high (a two-part configuration) and at low (a three-part configuration including an additional preconcentration zone) concentrations, were developed. The principle for flavonoid detection was based on their ability to reduce silver nitrate to silver nanoparticles (AgNPs) producing an intense surface plasmon resonance band. The effects of main factors on the formation of AgNPs and the analytical response in proposed μPADs were studied. The concentration limits of detection were 2.3, 5.2, 14 μg mL−1 and the absolute limits of detection were 0.12, 0.26, 0.70 μg for quercetin, morin and dihydroquercetin, respectively. To determine flavonoids at low concentration level, a three-part configuration of a composable μPAD utilizing preconcentration on magnetic hypercrosslinked polystyrene was used. It was shown that such preconcentration increases 5 times sensitivity of morin determination. The method was applied to the analysis of hawthorn tincture and onion peel.
Citations by journals
1
2
|
|
Sensors
|
Sensors
2 publications, 20%
|
Membranes
|
Membranes
1 publication, 10%
|
Chemical Papers
|
Chemical Papers
1 publication, 10%
|
Journal of Hazardous Materials
|
Journal of Hazardous Materials
1 publication, 10%
|
Sensors and Actuators, B: Chemical
|
Sensors and Actuators, B: Chemical
1 publication, 10%
|
Biosensors and Bioelectronics
|
Biosensors and Bioelectronics
1 publication, 10%
|
Analytical Sciences
|
Analytical Sciences
1 publication, 10%
|
eFood
|
eFood
1 publication, 10%
|
Microchimica Acta
|
Microchimica Acta
1 publication, 10%
|
1
2
|
Citations by publishers
1
2
3
|
|
Multidisciplinary Digital Publishing Institute (MDPI)
|
Multidisciplinary Digital Publishing Institute (MDPI)
3 publications, 30%
|
Elsevier
|
Elsevier
3 publications, 30%
|
Springer Nature
|
Springer Nature
2 publications, 20%
|
Japan Society for Analytical Chemistry
|
Japan Society for Analytical Chemistry
1 publication, 10%
|
Wiley
|
Wiley
1 publication, 10%
|
1
2
3
|
- We do not take into account publications that without a DOI.
- Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
- Statistics recalculated weekly.
{"yearsCitations":{"type":"bar","data":{"show":true,"labels":[2021,2022,2023],"ids":[0,0,0],"codes":[0,0,0],"imageUrls":["","",""],"datasets":[{"label":"Citations number","data":[1,6,3],"backgroundColor":["#3B82F6","#3B82F6","#3B82F6"],"percentage":["10","60","30"],"barThickness":null}]},"options":{"indexAxis":"x","maintainAspectRatio":true,"scales":{"y":{"ticks":{"precision":0,"autoSkip":false,"font":{"family":"Montserrat"},"color":"#000000"}},"x":{"ticks":{"stepSize":1,"precision":0,"font":{"family":"Montserrat"},"color":"#000000"}}},"plugins":{"legend":{"position":"top","labels":{"font":{"family":"Montserrat"},"color":"#000000"}},"title":{"display":true,"text":"Citations per year","font":{"size":24,"family":"Montserrat","weight":600},"color":"#000000"}}}},"journals":{"type":"bar","data":{"show":true,"labels":["Sensors","Membranes","Chemical Papers","Journal of Hazardous Materials","Sensors and Actuators, B: Chemical","Biosensors and Bioelectronics","Analytical Sciences","eFood","Microchimica Acta"],"ids":[18435,6479,4048,23695,22419,18799,2815,28701,11314],"codes":[0,0,0,0,0,0,0,0,0],"imageUrls":["\/storage\/images\/resized\/MjH1ITP7lMYGxeqUZfkt2BnVLgjkk413jwBV97XX_medium.webp","\/storage\/images\/resized\/MjH1ITP7lMYGxeqUZfkt2BnVLgjkk413jwBV97XX_medium.webp","\/storage\/images\/resized\/voXLqlsvTwv5p3iMQ8Dhs95nqB4AXOG7Taj7G4ra_medium.webp","\/storage\/images\/resized\/GDnYOu1UpMMfMMRV6Aqle4H0YLLsraeD9IP9qScG_medium.webp","\/storage\/images\/resized\/GDnYOu1UpMMfMMRV6Aqle4H0YLLsraeD9IP9qScG_medium.webp","\/storage\/images\/resized\/GDnYOu1UpMMfMMRV6Aqle4H0YLLsraeD9IP9qScG_medium.webp","\/storage\/images\/resized\/MriDiasGda8aAymM983PIz18dzVMXwO888XReHom_medium.webp","\/storage\/images\/resized\/bRyGpdm98BkAUYiK1YFNpl5Z7hPu6Gd87gbIeuG3_medium.webp","\/storage\/images\/resized\/voXLqlsvTwv5p3iMQ8Dhs95nqB4AXOG7Taj7G4ra_medium.webp"],"datasets":[{"label":"","data":[2,1,1,1,1,1,1,1,1],"backgroundColor":["#3B82F6","#3B82F6","#3B82F6","#3B82F6","#3B82F6","#3B82F6","#3B82F6","#3B82F6","#3B82F6"],"percentage":[20,10,10,10,10,10,10,10,10],"barThickness":13}]},"options":{"indexAxis":"y","maintainAspectRatio":false,"scales":{"y":{"ticks":{"precision":0,"autoSkip":false,"font":{"family":"Montserrat"},"color":"#000000"}},"x":{"ticks":{"stepSize":null,"precision":0,"font":{"family":"Montserrat"},"color":"#000000"}}},"plugins":{"legend":{"position":"top","labels":{"font":{"family":"Montserrat"},"color":"#000000"}},"title":{"display":true,"text":"Journals","font":{"size":24,"family":"Montserrat","weight":600},"color":"#000000"}}}},"publishers":{"type":"bar","data":{"show":true,"labels":["Multidisciplinary Digital Publishing Institute (MDPI)","Elsevier","Springer Nature","Japan Society for Analytical Chemistry","Wiley"],"ids":[202,17,8,1070,11],"codes":[0,0,0,0,0],"imageUrls":["\/storage\/images\/resized\/MjH1ITP7lMYGxeqUZfkt2BnVLgjkk413jwBV97XX_medium.webp","\/storage\/images\/resized\/GDnYOu1UpMMfMMRV6Aqle4H0YLLsraeD9IP9qScG_medium.webp","\/storage\/images\/resized\/voXLqlsvTwv5p3iMQ8Dhs95nqB4AXOG7Taj7G4ra_medium.webp","\/storage\/images\/resized\/MriDiasGda8aAymM983PIz18dzVMXwO888XReHom_medium.webp","\/storage\/images\/resized\/bRyGpdm98BkAUYiK1YFNpl5Z7hPu6Gd87gbIeuG3_medium.webp"],"datasets":[{"label":"","data":[3,3,2,1,1],"backgroundColor":["#3B82F6","#3B82F6","#3B82F6","#3B82F6","#3B82F6"],"percentage":[30,30,20,10,10],"barThickness":13}]},"options":{"indexAxis":"y","maintainAspectRatio":false,"scales":{"y":{"ticks":{"precision":0,"autoSkip":false,"font":{"family":"Montserrat"},"color":"#000000"}},"x":{"ticks":{"stepSize":null,"precision":0,"font":{"family":"Montserrat"},"color":"#000000"}}},"plugins":{"legend":{"position":"top","labels":{"font":{"family":"Montserrat"},"color":"#000000"}},"title":{"display":true,"text":"Publishers","font":{"size":24,"family":"Montserrat","weight":600},"color":"#000000"}}}}}
Metrics
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Gutorova S. V. et al. Composable paper-based analytical devices for determination of flavonoids // Sensors and Actuators, B: Chemical. 2021. Vol. 331. p. 129398.
GOST all authors (up to 50)
Copy
Gutorova S. V., Apyari V. V., Kalinin V. I., Gorbunova M. V., Dmitrienko S., Furletov A. A. Composable paper-based analytical devices for determination of flavonoids // Sensors and Actuators, B: Chemical. 2021. Vol. 331. p. 129398.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.snb.2020.129398
UR - https://doi.org/10.1016%2Fj.snb.2020.129398
TI - Composable paper-based analytical devices for determination of flavonoids
T2 - Sensors and Actuators, B: Chemical
AU - Gutorova, Svetlana V
AU - Apyari, Vladimir V
AU - Kalinin, Vyacheslav I
AU - Gorbunova, Maria V
AU - Dmitrienko, S
AU - Furletov, Aleksei A
PY - 2021
DA - 2021/03/01 00:00:00
PB - Elsevier
SP - 129398
VL - 331
SN - 0925-4005
ER -
Cite this
BibTex
Copy
@article{2021_Gutorova,
author = {Svetlana V Gutorova and Vladimir V Apyari and Vyacheslav I Kalinin and Maria V Gorbunova and S Dmitrienko and Aleksei A Furletov},
title = {Composable paper-based analytical devices for determination of flavonoids},
journal = {Sensors and Actuators, B: Chemical},
year = {2021},
volume = {331},
publisher = {Elsevier},
month = {mar},
url = {https://doi.org/10.1016%2Fj.snb.2020.129398},
pages = {129398},
doi = {10.1016/j.snb.2020.129398}
}