Open Access
Open access
Journal of the International AIDS Society, volume 28, issue 2

Acceptability of an annual tenofovir alafenamide implant for HIV prevention in South African women: findings from the CAPRISA 018 Phase I clinical trial

Tanuja N Gengiah 1
Craig J Heck 2, 3
Lara Lewis 1
Leila E. Mansoor 1
Ishana Harkoo 1
Nqobile Myeni 1
Marc M Baum 4
John A. Moss 4
JAMES F. ROONEY 5
Catherine Hankins 6
Bruno Pozzetto 7
Salim Abdool Karim 1, 2
Show full list: 13 authors
1
 
Centre for the AIDS Programme of Research in South Africa Durban South Africa
4
 
Oak Crest Institute of Science Monrovia California USA
5
 
Gilead Sciences, Inc. Foster City California USA
7
 
Centre International de Recherche en Infectiologie (CIRI), Team GIMAP Jean Monnet University of Saint‐Etienne Saint‐Etienne France
Publication typeJournal Article
Publication date2025-02-21
scimago Q1
SJR1.934
CiteScore8.6
Impact factor4.6
ISSN17582652
Abstract
Introduction

Long‐acting HIV pre‐exposure prophylaxis promises to improve uptake, adherence and persistence challenges experienced with daily oral tablets. We assessed the acceptability of an annual tenofovir alafenamide (TAF) implant in South African women enrolled from 9 July 2020 until 31 May 2022 in a Phase I trial.

Methods

Six women received one TAF implant for 4 weeks (Group 1), after which 30 women were randomized (4:1, TAF to placebo ratio) to receive 1 or 2 TAF or placebo implants for 48 weeks (Group 2), before trial discontinuation. Acceptability assessments were conducted pre‐ and post‐implant removal. Implant attributes (size, quantity, insertion site, palpability, visibility) and physical experiences (insertion/removal procedures, implant site reactions [ISRs]) were rated on a scale of 1 (highly unacceptable) to 6 (highly acceptable), with 4 being the acceptability threshold. The mean (range) of the mean acceptability scores across all pre‐removal visits were calculated, including stratification by removal timing (early vs. scheduled). Implant likes and dislikes were also assessed.

Results

The median participant age was 26 years. Prior to implant removal, the mean (range) acceptability scores were 5.4 (3.6–6.0) for product attributes and 5.1 (1.7–6.0) for physical experiences. Eleven (31%) participants had early implant removals, occurring on average 19 weeks (range 2–27 weeks) after insertion. The proportion of study visits reporting adherence measure as unacceptable in early versus scheduled removals: ISRs (50% vs. 19%), visibility (30% vs. 15%), palpability (14% vs. 8%), pain (16% vs. 4%) and implant quantity (13% vs. 1%). Pre‐removal acceptability scores for ISRs (p = 0.003) and physical experiences (p = 0.05) were significantly associated with early removal. Overall, mean (range) acceptability scores were 5.8 (4.0–6.0) and 5.9 (4.7–6.0) for lifestyle compatibility and likelihood of recommendation, respectively. After removal, 39% of participants found ISRs unacceptable, followed by 22% citing implant visibility. Potential for long‐term HIV protection, followed by discreet and convenient use, were most liked, while ISRs were the most disliked aspect.

Conclusions

While implant attributes, physical experiences and insertion/removal procedures were largely acceptable, local ISRs significantly reduced tolerability and acceptability, resulting in higher‐than‐expected early removals. The potential benefits of an annual TAF implant may be undermined unless tolerability is improved.

Found 
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex
Found error?