volume 6 issue 4 publication number e1381

Risks of stannous chloride without filtration for hexavalent chromium treatment

Anthony M. Kennedy 1
Craig Gorman 1
Mathieu Medina 1
Douglas Whichard 2
Elaine Edjan 2
Tarrah Henrie 2
Chad Seidel 1
Craig Gorman 1
1
 
Corona Environmental Consulting, LLC Louisville Colorado USA
2
 
California Water Service California San Jose USA
Publication typeJournal Article
Publication date2024-07-01
scimago Q2
wos Q3
SJR0.600
CiteScore4.5
Impact factor1.8
ISSN25778161
Abstract

With increasing interest in using stannous chloride without filtration to achieve hexavalent chromium maximum contaminant level compliance in California, there is new urgency to quantify its effects on water quality and risks to public health manifested in distribution and premise plumbing systems. Accordingly, a 12‐week groundwater pilot study was completed using ubiquitous premise plumbing materials under flowing (to waste) and stagnating conditions of hexavalent chromium‐containing groundwater following stannous chloride addition without filtration. Results quantified the accumulation and release of chromium and tin, with total chromium concentrations exceeding regulatory or acceptable levels under stagnating conditions. Sediment with elevated chromium, tin, arsenic, and manganese concentrations was also observed. Given these observations would likely occur and worsen over time in distribution systems that cumulatively serve large populations, the use of stannous chloride without filtration represents an unacceptable risk to public health compared to other, more well‐established, best available technologies.

Found 

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
0
Share
Cite this
GOST |
Cite this
GOST Copy
Kennedy A. M. et al. Risks of stannous chloride without filtration for hexavalent chromium treatment // AWWA Water Science. 2024. Vol. 6. No. 4. e1381
GOST all authors (up to 50) Copy
Kennedy A. M., Gorman C., Medina M., Whichard D., Edjan E., Henrie T., Seidel C., Gorman C. Risks of stannous chloride without filtration for hexavalent chromium treatment // AWWA Water Science. 2024. Vol. 6. No. 4. e1381
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1002/aws2.1381
UR - https://awwa.onlinelibrary.wiley.com/doi/10.1002/aws2.1381
TI - Risks of stannous chloride without filtration for hexavalent chromium treatment
T2 - AWWA Water Science
AU - Kennedy, Anthony M.
AU - Gorman, Craig
AU - Medina, Mathieu
AU - Whichard, Douglas
AU - Edjan, Elaine
AU - Henrie, Tarrah
AU - Seidel, Chad
AU - Gorman, Craig
PY - 2024
DA - 2024/07/01
PB - Wiley
IS - 4
VL - 6
SN - 2577-8161
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2024_Kennedy,
author = {Anthony M. Kennedy and Craig Gorman and Mathieu Medina and Douglas Whichard and Elaine Edjan and Tarrah Henrie and Chad Seidel and Craig Gorman},
title = {Risks of stannous chloride without filtration for hexavalent chromium treatment},
journal = {AWWA Water Science},
year = {2024},
volume = {6},
publisher = {Wiley},
month = {jul},
url = {https://awwa.onlinelibrary.wiley.com/doi/10.1002/aws2.1381},
number = {4},
pages = {e1381},
doi = {10.1002/aws2.1381}
}