том 49 издание 1 страницы 682-701

Neurostimulation success rate of repetitive‐pulse focused ultrasound in an in vivo giant axon model: An acoustic parametric study

Тип публикацииJournal Article
Дата публикации2021-12-07
scimago Q1
wos Q1
white level БС1
SJR0.986
CiteScore6.4
Impact factor3.2
ISSN00942405, 24734209
General Medicine
Краткое описание
Focused ultrasound (FUS) is a promising tool to develop new modalities of therapeutic neurostimulation. The ability of FUS to stimulate the nervous system, in a noninvasive and spatiotemporally precise manner, has been demonstrated in animals and human subjects, but the underlying biomechanisms are not fully understood yet. The objective of the present study was to investigate the bioeffects involved in the generation of trains of action potentials (APs) by repetitive-pulse FUS stimuli in a simple invertebrate neural model.The respective influences of different acoustic parameters on the neurostimulation success rate (NSR), defined as the rate of FUS stimuli capable of evoking at least one AP, were explored using the system of afferent nerves and giant fibers of Lumbricus terrestris as neural model. Each parameter was studied independently by administering random FUS sequences while keeping all but one FUS parameter constant. The NSR was evaluated as a function of (i) the spatial-average pulse-average intensity (Isapa ); (ii) the pulse duration (PD); (iii) the pulse repetition frequency (PRF); iv) the number of cycles per pulse (Ncycles ); (v) two ultrasound frequencies, f0 = 1.1 MHz and f3 = 3.3 MHz, corresponding to the fundamental and third-harmonic resonant frequencies of the FUS transducer, respectively (spherical, radius of curvature: 50 mm); and (vi) levels of emerging stable cavitation and inertial cavitation.The NSR associated to 1.1 MHz repetitive-pulse FUS stimuli was found to increase as a function of increasing Isapa , PD, PRF, and Ncycles . When evaluating each parameter at f = 1.1 MHz, it was observed that NSRs close to 100% were achieved when sufficiently elevating their respective values. When computing the NSR as a function of the spatial-average, temporal-average intensity (Isata ), defined as the product of PRF, PD, and Isapa , a significant elevation of the NSR from 0% to close to 100% was measured by increasing Isata from values approximate to 4 W/cm2 to values higher than 12 W/cm2 . No clear and consistent trend was observed in trials aimed at exploring the effects of different levels of stable and inertial acoustic cavitation on the NSR. Finally, the feasibility of inducing neural responses with 3.3 MHz repetitive-pulse FUS stimuli was also demonstrated with NSRs reaching up to 60%, in the range of FUS parameters studied.The time-averaged value of the radiation force per unit volume of tissue is proportional to the acoustic intensity. As a result, the observations from this study suggest that the neural structure responding to the stimulus is sensitive to the mean radiation force carried by the FUS sequence, regardless of the combination of FUS parameters giving rise to such force. The results from this study further revealed the existence of a minimal activation threshold with regard to Isapa .
Для доступа к списку цитирований публикации необходимо авторизоваться.

Топ-30

Журналы

1
Frontiers in Physiology
1 публикация, 20%
Brain Sciences
1 публикация, 20%
Brain Stimulation
1 публикация, 20%
Neuroscience
1 публикация, 20%
Biological Psychiatry
1 публикация, 20%
1

Издатели

1
2
3
Elsevier
3 публикации, 60%
Frontiers Media S.A.
1 публикация, 20%
MDPI
1 публикация, 20%
1
2
3
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
5
Поделиться
Цитировать
ГОСТ |
Цитировать
Vion-Bailly J. et al. Neurostimulation success rate of repetitive‐pulse focused ultrasound in an in vivo giant axon model: An acoustic parametric study // Medical Physics. 2021. Vol. 49. No. 1. pp. 682-701.
ГОСТ со всеми авторами (до 50) Скопировать
Vion-Bailly J., Suarez Castellanos I. M., Chapelon J. Y., Carpentier A., N’djin W. A. Neurostimulation success rate of repetitive‐pulse focused ultrasound in an in vivo giant axon model: An acoustic parametric study // Medical Physics. 2021. Vol. 49. No. 1. pp. 682-701.
RIS |
Цитировать
TY - JOUR
DO - 10.1002/mp.15358
UR - https://doi.org/10.1002/mp.15358
TI - Neurostimulation success rate of repetitive‐pulse focused ultrasound in an in vivo giant axon model: An acoustic parametric study
T2 - Medical Physics
AU - Vion-Bailly, Jérémy
AU - Suarez Castellanos, Ivan M.
AU - Chapelon, Jean Yves
AU - Carpentier, Alexandre
AU - N’djin, William A.
PY - 2021
DA - 2021/12/07
PB - Wiley
SP - 682-701
IS - 1
VL - 49
PMID - 34796512
SN - 0094-2405
SN - 2473-4209
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2021_Vion-Bailly,
author = {Jérémy Vion-Bailly and Ivan M. Suarez Castellanos and Jean Yves Chapelon and Alexandre Carpentier and William A. N’djin},
title = {Neurostimulation success rate of repetitive‐pulse focused ultrasound in an in vivo giant axon model: An acoustic parametric study},
journal = {Medical Physics},
year = {2021},
volume = {49},
publisher = {Wiley},
month = {dec},
url = {https://doi.org/10.1002/mp.15358},
number = {1},
pages = {682--701},
doi = {10.1002/mp.15358}
}
MLA
Цитировать
Vion-Bailly, Jérémy, et al. “Neurostimulation success rate of repetitive‐pulse focused ultrasound in an in vivo giant axon model: An acoustic parametric study.” Medical Physics, vol. 49, no. 1, Dec. 2021, pp. 682-701. https://doi.org/10.1002/mp.15358.
Ошибка в публикации?