Inspection and Testing of Electroencephalographs, Electromyographs, and Evoked Response Equipment

Publication typeBook Chapter
Publication date2017-10-27
SJR
CiteScore
Impact factor
ISSN18645763, 18645771
Abstract
The chapter deals with the inspection of neurodiagnostic equipment based on measurement of electrophysiological signals in order to detect eventual problems and prevent them from becoming serious safety risks. In the first section of the text a brief description of the human neuromuscular system is given, followed by description and short historical overview of considered neurodiagnostic methods: electroencephalography (EEG) including evoked potentials (EP), electromyography (EMG) and nerve conduction study (NCS). Operating principle of computer-controlled neurodiagnostic instrument is explained using generic block diagram. The next sections discuss potential harms and hazards associated with the use of neurodiagnostic equipment as well as standards and regulations concerning basic safety and essential performance requirements for mentioned equipment. The last section describes inspection procedure for periodical testing of modern computer-based nerodiagnostic instruments in the field.
Found 
Found 

Top-30

Journals

1
Expert Review of Medical Devices
1 publication, 100%
1

Publishers

1
Taylor & Francis
1 publication, 100%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
1
Share
Cite this
GOST |
Cite this
GOST Copy
Cifrek M. Inspection and Testing of Electroencephalographs, Electromyographs, and Evoked Response Equipment // Irreversible Electroporation. 2017. pp. 141-157.
GOST all authors (up to 50) Copy
Cifrek M. Inspection and Testing of Electroencephalographs, Electromyographs, and Evoked Response Equipment // Irreversible Electroporation. 2017. pp. 141-157.
RIS |
Cite this
RIS Copy
TY - GENERIC
DO - 10.1007/978-981-10-6650-4_7
UR - https://doi.org/10.1007/978-981-10-6650-4_7
TI - Inspection and Testing of Electroencephalographs, Electromyographs, and Evoked Response Equipment
T2 - Irreversible Electroporation
AU - Cifrek, Mario
PY - 2017
DA - 2017/10/27
PB - Springer Nature
SP - 141-157
SN - 1864-5763
SN - 1864-5771
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@incollection{2017_Cifrek,
author = {Mario Cifrek},
title = {Inspection and Testing of Electroencephalographs, Electromyographs, and Evoked Response Equipment},
publisher = {Springer Nature},
year = {2017},
pages = {141--157},
month = {oct}
}