volume 53 issue 11 pages 1467-1479

Sodium MRI of Fish on 0.5T Clinical Scanner

Publication typeJournal Article
Publication date2022-05-30
scimago Q3
wos Q4
SJR0.308
CiteScore2.2
Impact factor1.1
ISSN09379347, 16137507
Atomic and Molecular Physics, and Optics
Abstract
Sodium (23Na) magnetic resonance imaging (MRI) provides information about intra- and intercellular processes useful for medical diagnostics, such as Huntington’s disease, diabetes, etc. 23Na MRI is also used for technological applications such as the analysis of salt content in food products and the assessment of their characteristics using relaxation measurements. Due to 3–4 order difference in the MRI sensitivity for proton and sodium detection, 23Na MRI is usually performed using high-field MRI scanners. Current study explores feasibility of 23Na MRI at the low field 0.5T clinical scanner using different fish species. Using the 3D gradient echo method with the parameters: repetition time = 44.7 ms, echo time = 12 ms, and flip angle = 75°, 23Na MRI of euthanized and thawed fish of different orders (according to biological classification) with an isotropic resolution of 6 mm were obtained. For the assignment of anatomical structures of fish, proton images with an isotropic resolution of 2 mm were also obtained, and combined 1H and 23Na images were constructed. The analysis of the obtained images, including anatomical aspects, has been carried out. Using 23Na nuclear magnetic resonance spectroscopy methods, the rate of sodium excretion was assessed for typical methods of fish conservation for their subsequent use as anatomical specimens and exhibits in museums and scientific laboratories. The results of this work can be used to assess the potential of low-field multinuclear MRI, in biology, and technological (non-medical) applications, particularly, in the analysis of food and the development of methods for preservation of living tissues.
Found 
Found 

Top-30

Journals

1
Applied Magnetic Resonance
1 publication, 100%
1

Publishers

1
Springer Nature
1 publication, 100%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
1
Share
Cite this
GOST |
Cite this
GOST Copy
Anisimov N. V. et al. Sodium MRI of Fish on 0.5T Clinical Scanner // Applied Magnetic Resonance. 2022. Vol. 53. No. 11. pp. 1467-1479.
GOST all authors (up to 50) Copy
Anisimov N. V., Shakhparonov V. V., Romanov A., Tarasova A. A., Usanov I. A., Pavlova O., Gulyaev M. V., Pirogov Yu. A. Sodium MRI of Fish on 0.5T Clinical Scanner // Applied Magnetic Resonance. 2022. Vol. 53. No. 11. pp. 1467-1479.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1007/s00723-022-01480-0
UR - https://link.springer.com/10.1007/s00723-022-01480-0
TI - Sodium MRI of Fish on 0.5T Clinical Scanner
T2 - Applied Magnetic Resonance
AU - Anisimov, N V
AU - Shakhparonov, V V
AU - Romanov, A.V.
AU - Tarasova, A A
AU - Usanov, I A
AU - Pavlova, O.S.
AU - Gulyaev, M V
AU - Pirogov, Yu A
PY - 2022
DA - 2022/05/30
PB - Springer Nature
SP - 1467-1479
IS - 11
VL - 53
SN - 0937-9347
SN - 1613-7507
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2022_Anisimov,
author = {N V Anisimov and V V Shakhparonov and A.V. Romanov and A A Tarasova and I A Usanov and O.S. Pavlova and M V Gulyaev and Yu A Pirogov},
title = {Sodium MRI of Fish on 0.5T Clinical Scanner},
journal = {Applied Magnetic Resonance},
year = {2022},
volume = {53},
publisher = {Springer Nature},
month = {may},
url = {https://link.springer.com/10.1007/s00723-022-01480-0},
number = {11},
pages = {1467--1479},
doi = {10.1007/s00723-022-01480-0}
}
MLA
Cite this
MLA Copy
Anisimov, N. V., et al. “Sodium MRI of Fish on 0.5T Clinical Scanner.” Applied Magnetic Resonance, vol. 53, no. 11, May. 2022, pp. 1467-1479. https://link.springer.com/10.1007/s00723-022-01480-0.