Evaluation of semicircular canal dehiscence using micro-computed tomography and comparison with cone-beam computed tomography
Buket Oguz
1
,
Ferhat Geneci
1
,
Mert Ocak
2
,
Mehmet Fatih Sentürk
3
,
Emine Şebnem Kurşun Çakmak
4
,
Kaan Orhan
5
,
K. Desdicioglu
1
4
Тип публикации: Journal Article
Дата публикации: 2025-04-03
scimago Q2
wos Q2
БС2
SJR: 0.448
CiteScore: 2.7
Impact factor: 1.7
ISSN: 14476959, 1447073X
Краткое описание
Semicircular canal dehiscence (SSCD), is a rare bony defect that reveals a third window of semicircular canal except oval and round window. Dizziness, acute vertigo attacks, conductive hearing loss, tinnitus and amplified heartbeat sounds are the symptoms of dehiscence. The aim of this article is to analyze the length and location of semicircular canal dehiscence as superior (anterior), inferior (posterior), or lateral (horizontal) canals using micro-CT and compare it with Cone beam CT. A total of 39 dry temporal bones without visible damage were examined both in Micro CT and Cone beam CT. Measurements were made on these cross-sectional images using the CTAn software. Statistical significance was defined as p < 0.05. When examining Micro-CT images, only 4 canals showed dehiscence among 39 bones. The dehicences were observed in both lateral, superior, and posterior semicircular canals. One dehiscence was in the lateral semicircular canal, two were in the superior semicircular canal, and the last one was in the posterior semicircular canal. In CBCT images, dehiscence was observed in a total of 11 canals among the 39 bones. Two dehiscences were in the lateral semicircular canal, three in the posterior semicircular canal, and six in the superior semicircular canal. There was a significant difference between Micro CT and Cone beam CT in terms of dehiscence detection (p < 0,05). Consequently, this study emphasizes the potential danger of an uncertain diagnosis of canal dehiscence with CT in individuals with minor irregularities in Cone beam CT scans, which could result in potentially inappropriate surgical interventions.
Найдено
Ничего не найдено, попробуйте изменить настройки фильтра.
Вы ученый?
Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
0
Всего цитирований:
0
Цитировать
ГОСТ |
RIS |
BibTex
Цитировать
ГОСТ
Скопировать
Oguz B. et al. Evaluation of semicircular canal dehiscence using micro-computed tomography and comparison with cone-beam computed tomography // Anatomical Science International. 2025.
ГОСТ со всеми авторами (до 50)
Скопировать
Oguz B., Geneci F., Ocak M., Sentürk M. F., Çakmak E. Ş. K., Orhan K., Desdicioglu K. Evaluation of semicircular canal dehiscence using micro-computed tomography and comparison with cone-beam computed tomography // Anatomical Science International. 2025.
Цитировать
RIS
Скопировать
TY - JOUR
DO - 10.1007/s12565-025-00835-4
UR - https://link.springer.com/10.1007/s12565-025-00835-4
TI - Evaluation of semicircular canal dehiscence using micro-computed tomography and comparison with cone-beam computed tomography
T2 - Anatomical Science International
AU - Oguz, Buket
AU - Geneci, Ferhat
AU - Ocak, Mert
AU - Sentürk, Mehmet Fatih
AU - Çakmak, Emine Şebnem Kurşun
AU - Orhan, Kaan
AU - Desdicioglu, K.
PY - 2025
DA - 2025/04/03
PB - Springer Nature
SN - 1447-6959
SN - 1447-073X
ER -
Цитировать
BibTex (до 50 авторов)
Скопировать
@article{2025_Oguz,
author = {Buket Oguz and Ferhat Geneci and Mert Ocak and Mehmet Fatih Sentürk and Emine Şebnem Kurşun Çakmak and Kaan Orhan and K. Desdicioglu},
title = {Evaluation of semicircular canal dehiscence using micro-computed tomography and comparison with cone-beam computed tomography},
journal = {Anatomical Science International},
year = {2025},
publisher = {Springer Nature},
month = {apr},
url = {https://link.springer.com/10.1007/s12565-025-00835-4},
doi = {10.1007/s12565-025-00835-4}
}