Abstract
We report the development of a sensitive label-free, cost-effective detection system with simultaneous multi-channel measurement of open circuit potential (OCP) variations for the detection of prostate specific antigen (PSA). We demonstrate a significant increase of 600 times in the sensitivity as compared to the reported literature. To accurately measure OCP variations, a complete monolithic field-effect transistor (FET)-input ultra-low input bias current instrumentation amplifier is used to form the electronic circuit to measure the variation between a working electrode and a reference electrode. This amplifier electronic system setup provides a differential voltage measurement with high input impedance and low input bias current. Since no current is applied to the electrochemical system, a true and accurate measurement of the variation can be performed. This is the first report on the use of DNA aptamers with an OCP system where we employed a DNA aptamer against PSA. An optimised ratio of anti-PSA DNA aptamer with 6-mercapto-1-hexanol (MCH) was used to fabricate the aptasensor using gold electrodes. The electrodes are hosted in a cell with an automated flow system. A wide range of concentrations of PSA (0.1 to 100 ng/mL) were injected through the system. The sensor could potentially differentiate 0.1 ng/mL PSA from blank measurement, which is well below the required clinical range (>1 ng/mL). The sensor was also challenged with 4% human serum albumin and human kallikrein2 as control proteins where the sensor demonstrated excellent selectivity. The developed system can be further generalised to various other targets using specific probes.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
|
|
|
Analytical Chemistry
2 publications, 11.76%
|
|
|
Sensors
1 publication, 5.88%
|
|
|
BioNanoScience
1 publication, 5.88%
|
|
|
Analytica Chimica Acta
1 publication, 5.88%
|
|
|
PLoS ONE
1 publication, 5.88%
|
|
|
Sensors and Actuators, B: Chemical
1 publication, 5.88%
|
|
|
Microchemical Journal
1 publication, 5.88%
|
|
|
Biosensors and Bioelectronics
1 publication, 5.88%
|
|
|
Clinical Biochemistry
1 publication, 5.88%
|
|
|
Journal of Nanomaterials
1 publication, 5.88%
|
|
|
Polymers
1 publication, 5.88%
|
|
|
Microchimica Acta
1 publication, 5.88%
|
|
|
Russian Chemical Reviews
1 publication, 5.88%
|
|
|
1
2
|
Publishers
|
1
2
3
4
5
|
|
|
Elsevier
5 publications, 29.41%
|
|
|
Springer Nature
4 publications, 23.53%
|
|
|
MDPI
2 publications, 11.76%
|
|
|
American Chemical Society (ACS)
2 publications, 11.76%
|
|
|
Public Library of Science (PLoS)
1 publication, 5.88%
|
|
|
Hindawi Limited
1 publication, 5.88%
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
1 publication, 5.88%
|
|
|
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 publication, 5.88%
|
|
|
1
2
3
4
5
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
17
Total citations:
17
Citations from 2024:
4
(23.53%)
Cite this
GOST |
RIS |
BibTex |
MLA
Cite this
GOST
Copy
Wong L. C. C., Jolly P., Estrela P. Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers // BioNanoScience. 2017. Vol. 8. No. 2. pp. 701-706.
GOST all authors (up to 50)
Copy
Wong L. C. C., Jolly P., Estrela P. Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers // BioNanoScience. 2017. Vol. 8. No. 2. pp. 701-706.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1007/s12668-017-0408-0
UR - https://doi.org/10.1007/s12668-017-0408-0
TI - Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers
T2 - BioNanoScience
AU - Wong, Lai Chun Caleb
AU - Jolly, Pawan
AU - Estrela, Pedro
PY - 2017
DA - 2017/04/01
PB - Springer Nature
SP - 701-706
IS - 2
VL - 8
SN - 2191-1630
SN - 2191-1649
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2017_Wong,
author = {Lai Chun Caleb Wong and Pawan Jolly and Pedro Estrela},
title = {Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers},
journal = {BioNanoScience},
year = {2017},
volume = {8},
publisher = {Springer Nature},
month = {apr},
url = {https://doi.org/10.1007/s12668-017-0408-0},
number = {2},
pages = {701--706},
doi = {10.1007/s12668-017-0408-0}
}
Cite this
MLA
Copy
Wong, Lai Chun Caleb, et al. “Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers.” BioNanoScience, vol. 8, no. 2, Apr. 2017, pp. 701-706. https://doi.org/10.1007/s12668-017-0408-0.