volume 8 issue 2 pages 701-706

Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers

Publication typeJournal Article
Publication date2017-04-01
scimago Q3
wos Q3
SJR0.488
CiteScore4.5
Impact factor3.2
ISSN21911630, 21911649
Bioengineering
Biomedical Engineering
Abstract
We report the development of a sensitive label-free, cost-effective detection system with simultaneous multi-channel measurement of open circuit potential (OCP) variations for the detection of prostate specific antigen (PSA). We demonstrate a significant increase of 600 times in the sensitivity as compared to the reported literature. To accurately measure OCP variations, a complete monolithic field-effect transistor (FET)-input ultra-low input bias current instrumentation amplifier is used to form the electronic circuit to measure the variation between a working electrode and a reference electrode. This amplifier electronic system setup provides a differential voltage measurement with high input impedance and low input bias current. Since no current is applied to the electrochemical system, a true and accurate measurement of the variation can be performed. This is the first report on the use of DNA aptamers with an OCP system where we employed a DNA aptamer against PSA. An optimised ratio of anti-PSA DNA aptamer with 6-mercapto-1-hexanol (MCH) was used to fabricate the aptasensor using gold electrodes. The electrodes are hosted in a cell with an automated flow system. A wide range of concentrations of PSA (0.1 to 100 ng/mL) were injected through the system. The sensor could potentially differentiate 0.1 ng/mL PSA from blank measurement, which is well below the required clinical range (>1 ng/mL). The sensor was also challenged with 4% human serum albumin and human kallikrein2 as control proteins where the sensor demonstrated excellent selectivity. The developed system can be further generalised to various other targets using specific probes.
Found 
Found 

Top-30

Journals

1
2
Analytical Chemistry
2 publications, 11.76%
Sensors
1 publication, 5.88%
BioNanoScience
1 publication, 5.88%
Analytica Chimica Acta
1 publication, 5.88%
PLoS ONE
1 publication, 5.88%
Sensors and Actuators, B: Chemical
1 publication, 5.88%
Microchemical Journal
1 publication, 5.88%
Biosensors and Bioelectronics
1 publication, 5.88%
Clinical Biochemistry
1 publication, 5.88%
Journal of Nanomaterials
1 publication, 5.88%
Polymers
1 publication, 5.88%
Microchimica Acta
1 publication, 5.88%
Russian Chemical Reviews
1 publication, 5.88%
1
2

Publishers

1
2
3
4
5
Elsevier
5 publications, 29.41%
Springer Nature
4 publications, 23.53%
MDPI
2 publications, 11.76%
American Chemical Society (ACS)
2 publications, 11.76%
Public Library of Science (PLoS)
1 publication, 5.88%
Hindawi Limited
1 publication, 5.88%
Institute of Electrical and Electronics Engineers (IEEE)
1 publication, 5.88%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 publication, 5.88%
1
2
3
4
5
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
17
Share
Cite this
GOST |
Cite this
GOST Copy
Wong L. C. C., Jolly P., Estrela P. Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers // BioNanoScience. 2017. Vol. 8. No. 2. pp. 701-706.
GOST all authors (up to 50) Copy
Wong L. C. C., Jolly P., Estrela P. Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers // BioNanoScience. 2017. Vol. 8. No. 2. pp. 701-706.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1007/s12668-017-0408-0
UR - https://doi.org/10.1007/s12668-017-0408-0
TI - Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers
T2 - BioNanoScience
AU - Wong, Lai Chun Caleb
AU - Jolly, Pawan
AU - Estrela, Pedro
PY - 2017
DA - 2017/04/01
PB - Springer Nature
SP - 701-706
IS - 2
VL - 8
SN - 2191-1630
SN - 2191-1649
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2017_Wong,
author = {Lai Chun Caleb Wong and Pawan Jolly and Pedro Estrela},
title = {Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers},
journal = {BioNanoScience},
year = {2017},
volume = {8},
publisher = {Springer Nature},
month = {apr},
url = {https://doi.org/10.1007/s12668-017-0408-0},
number = {2},
pages = {701--706},
doi = {10.1007/s12668-017-0408-0}
}
MLA
Cite this
MLA Copy
Wong, Lai Chun Caleb, et al. “Development of a Sensitive Multiplexed Open Circuit Potential System for the Detection of Prostate Cancer Biomarkers.” BioNanoScience, vol. 8, no. 2, Apr. 2017, pp. 701-706. https://doi.org/10.1007/s12668-017-0408-0.