Abstract
Serpentine tube heat exchangers are widely applied in many industries, e.g. electronic equipment cooling, refrigeration, and spacecraft thermal control. These exchangers typically have curved and straight sections, however, the design of such heat exchangers with supercritical pressure fluid is challenging and not yet fully understood since complexity of convective heat transfer for supercritical pressure fluids and combined structure. In this paper, the convective heat transfer of supercritical pressure n-decane in a serpentine mini-tube with a straight section length of 16 mm and 80 mm, an inner diameter of 2 mm, and a curvature diameter of 16 mm was investigated experimentally and numerically, and the impact of secondary flow in the curved section on downstream heat transfer in the straight section was analysed. It was observed that when the straight section exceeds a specific impact length, the secondary flow effects from the upstream curved section become negligible and the convective heat transfer characteristics would transform into a fully developed feature in the straight tube. The impact length is concentrated in 1.5D-2.5D range and also in 3D-5D range when fluid properties change significantly. A correlation for the impact length has been proposed that distinguishes three regions with different heat transfer characteristics and allows the three regions to be treated separately when designing such heat exchangers. Finally, a feasible calculation of the Nu number for three regions has also been provided to design this type of heat exchangers.
Found 
Found 

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
1
Share
Cite this
GOST |
Cite this
GOST Copy
Qin T. et al. Influence of straight tube on serpentine tube heat exchanger with supercritical pressure fluid // Applied Thermal Engineering. 2025. Vol. 270. p. 126212.
GOST all authors (up to 50) Copy
Qin T., Xu R., Jiang P., Jiang P. Influence of straight tube on serpentine tube heat exchanger with supercritical pressure fluid // Applied Thermal Engineering. 2025. Vol. 270. p. 126212.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1016/j.applthermaleng.2025.126212
UR - https://linkinghub.elsevier.com/retrieve/pii/S135943112500804X
TI - Influence of straight tube on serpentine tube heat exchanger with supercritical pressure fluid
T2 - Applied Thermal Engineering
AU - Qin, Tianfei
AU - Xu, Ruina
AU - Jiang, Peixue
AU - Jiang, Peixue
PY - 2025
DA - 2025/07/01
PB - Elsevier
SP - 126212
VL - 270
SN - 1359-4311
SN - 1873-5606
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2025_Qin,
author = {Tianfei Qin and Ruina Xu and Peixue Jiang and Peixue Jiang},
title = {Influence of straight tube on serpentine tube heat exchanger with supercritical pressure fluid},
journal = {Applied Thermal Engineering},
year = {2025},
volume = {270},
publisher = {Elsevier},
month = {jul},
url = {https://linkinghub.elsevier.com/retrieve/pii/S135943112500804X},
pages = {126212},
doi = {10.1016/j.applthermaleng.2025.126212}
}