This study investigated how two different shading devices influenced cooling loads in a low-rise household during a summer peak load week, specifically while employing energy-efficient Light Emitting Diode illumination instead of natural light. This research analyzed two locations east of the Mediterranean Sea—Al Mafraq and Dara’a Cities—within the same climate zone: cold semi-arid steppe. A 3D thermodynamic design was developed using Revit and Design-Builder programs. The findings suggest that employing shading devices during peak load summer week effectively reduces the electricity demand for indoor cooling, which declined by 63 % and 58 % in Al Mafraq and Dara’a Cities, respectively. In comparison, the increase in lighting loads is not comparable to this decrease, which is 16 % in both locations. In Al-Mafraq City, the daily cooling load in the summer peak week from the 19th to the 23rd of August recorded the lowest value of the whole week at 7.50 kWh and reached its peak with a value of 10.09 kWh on the 23rd of August. On the other hand, Dara’a City recorded the lowest value of the whole week at 5.67 kWh and reached its peak with a value of 9.13 kWh on the 23rd of August, then to a value of 8.37 kWh.This research’s scientific novelty lies in the locations of the countries investigated, the relationship between the location’s sun hours and lighting and cooling loads, and its vulnerability to climate change.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
|
|
|
Next Sustainability
1 publication, 25%
|
|
|
Journal of Building Engineering
1 publication, 25%
|
|
|
Energy and Buildings
1 publication, 25%
|
|
|
1
|
Publishers
|
1
2
3
|
|
|
Elsevier
3 publications, 75%
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
1 publication, 25%
|
|
|
1
2
3
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
4
Total citations:
4
Citations from 2024:
4
(100%)
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Albatayneh A. et al. Trade-off lighting to minimize the cooling loads in semi-arid climate zone // Energy and Buildings. 2025. Vol. 328. p. 115100.
GOST all authors (up to 50)
Copy
Albatayneh A., Albadaineh R., Juaidi A., Abdallah R. Trade-off lighting to minimize the cooling loads in semi-arid climate zone // Energy and Buildings. 2025. Vol. 328. p. 115100.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.enbuild.2024.115100
UR - https://linkinghub.elsevier.com/retrieve/pii/S0378778824012167
TI - Trade-off lighting to minimize the cooling loads in semi-arid climate zone
T2 - Energy and Buildings
AU - Albatayneh, Aiman
AU - Albadaineh, Renad
AU - Juaidi, Adel
AU - Abdallah, Ramez
PY - 2025
DA - 2025/02/01
PB - Elsevier
SP - 115100
VL - 328
SN - 0378-7788
SN - 1872-6178
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2025_Albatayneh,
author = {Aiman Albatayneh and Renad Albadaineh and Adel Juaidi and Ramez Abdallah},
title = {Trade-off lighting to minimize the cooling loads in semi-arid climate zone},
journal = {Energy and Buildings},
year = {2025},
volume = {328},
publisher = {Elsevier},
month = {feb},
url = {https://linkinghub.elsevier.com/retrieve/pii/S0378778824012167},
pages = {115100},
doi = {10.1016/j.enbuild.2024.115100}
}