Open Access
Open access
volume 10 issue 4 pages e26123

Research on the zero-calibration gauge device

Zhichao Wu 1
Fan Lei 1
Furong Lei 1
Linan Wang 2
Yu Fu 2
Yu Fu 2
Publication typeJournal Article
Publication date2024-02-09
scimago Q1
wos Q1
SJR0.644
CiteScore4.1
Impact factor3.6
ISSN24058440
Multidisciplinary
Abstract

Abstract

To meet the demand for the track's geometric parameter detection equipment for train speed and high-speed aerodynamics tests, a zero-calibration gauge device is designed with the centering limit, height adjustment and horizontal display function in this paper. The bending situation of the zero-calibration gauge is analyzed and the processing technology is studied, which ensures the rationality and realizability of the design of zero-calibration gauge. Then the gauge zero value and the parallelism of the working surface of zero-calibration gauge have been experimentally tested. The experimental results show that the parameter of gauge zero value is 1434.829 mm with a standard deviation of 1.4 μm. The parallelism of the two upper working surfaces is 1.1 μm, and the parallelism of the two inner working surfaces is 4 μm. Finally, the uncertainty evaluation of zero-calibration gauge is completed. The measurement uncertainty of gauge zero value is 12 μm and the measurement uncertainty of height difference is 6 μm.
Found 
Found 

Top-30

Journals

1
Measurement: Journal of the International Measurement Confederation
1 publication, 100%
1

Publishers

1
Elsevier
1 publication, 100%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
1
Share
Cite this
GOST |
Cite this
GOST Copy
Wu Z. et al. Research on the zero-calibration gauge device // Heliyon. 2024. Vol. 10. No. 4. p. e26123.
GOST all authors (up to 50) Copy
Wu Z., Lei F., Lei F., Wang L., Fu Yu., Fu Yu. Research on the zero-calibration gauge device // Heliyon. 2024. Vol. 10. No. 4. p. e26123.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1016/j.heliyon.2024.e26123
UR - https://linkinghub.elsevier.com/retrieve/pii/S2405844024021546
TI - Research on the zero-calibration gauge device
T2 - Heliyon
AU - Wu, Zhichao
AU - Lei, Fan
AU - Lei, Furong
AU - Wang, Linan
AU - Fu, Yu
AU - Fu, Yu
PY - 2024
DA - 2024/02/09
PB - Elsevier
SP - e26123
IS - 4
VL - 10
PMID - 38375295
SN - 2405-8440
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2024_Wu,
author = {Zhichao Wu and Fan Lei and Furong Lei and Linan Wang and Yu Fu and Yu Fu},
title = {Research on the zero-calibration gauge device},
journal = {Heliyon},
year = {2024},
volume = {10},
publisher = {Elsevier},
month = {feb},
url = {https://linkinghub.elsevier.com/retrieve/pii/S2405844024021546},
number = {4},
pages = {e26123},
doi = {10.1016/j.heliyon.2024.e26123}
}
MLA
Cite this
MLA Copy
Wu, Zhichao, et al. “Research on the zero-calibration gauge device.” Heliyon, vol. 10, no. 4, Feb. 2024, p. e26123. https://linkinghub.elsevier.com/retrieve/pii/S2405844024021546.