Open Access
Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study
Henriette Lerner
1
,
Katalin Nagy
1
,
Nicola Pranno
2
,
Fernando Zarone
3
,
Oleg Admakin
4
,
Francesco Guido Mangano
4
2
Publication type: Journal Article
Publication date: 2021-10-01
scimago Q3
wos Q1
SJR: 0.332
CiteScore: 1.4
Impact factor: 5.5
ISSN: 03005712, 23456485, 23456418, 1879176X
PubMed ID:
34481929
General Dentistry
Abstract
To compare the trueness and precision of 3D-printed versus milled monolithic zirconia crowns (MZCs).A model of a maxilla with a prepared premolar was scanned with an industrial scanner (ATOSQ®, Gom) and an MZC was designed in computer-assisted-design (CAD) software (DentalCad®, Exocad). From that standard tessellation language (STL) file, 10 MZCs (test) were 3D-printed with a Lithography-based Ceramic Manufacturing (LCM) printer (CerafabS65®, Lithoz) and 10 MZCs (control) were milled using a 5-axis machine (DWX-52D®, DGShape). All MZCs were sintered and scanned with the aforementioned scanner. The surface data of each sample (overall crown, marginal area, occlusal surface) were superimposed to the original CAD file (ControlX®, Geomagic) to evaluate trueness: (90-10)/2, absolute average (ABS AVG) and root mean square (RMS) values were obtained for test and control groups (MathLab®, Mathworks) and used for analysis. Finally, the clinical precision (marginal adaptation, interproximal contacts) of test and control MZCs was investigated on a split-cast model printed (Solflex350®, Voco) from the CAD project, and compared.The milled MZCs had a significantly higher trueness than the 3D-printed ones, overall [(90-10)/2 printed 37.8 µm vs milled 21.2 µm; ABS AVG printed 27.2 µm vs milled 15.1 µm; RMS printed 33.2 µm vs milled 20.5 µm; p = 0.000005], at the margins [(90-10)/2 printed 25.6 µm vs milled 12.4 µm; ABS AVG printed 17.8 µm vs milled 9.4 µm; RMS printed 22.8 µm vs milled 15.6 µm; p= 0.000011] and at the occlusal level [(90-10)/2 printed 50.4 µm vs milled 21.9 µm; ABS AVG printed 29.6 µm vs milled 14.7 µm; RMS printed 38.9 µm vs milled 22.5 µm; p = 0.000005]. However, with regard to precision, both test and control groups scored highly, with no significant difference either in the quality of interproximal contact points (p = 0.355) or marginal closure (p = 0.355).Milled MZCs had a statistically higher trueness than 3D-printed ones; all crowns, however, showed high precision, compatible with the clinical use.Although milled MZCs remain more accurate than 3D-printed ones, the LCM technique seems able to guarantee the production of clinically precise zirconia crowns.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
5
10
15
20
25
30
|
|
|
Journal of Dentistry
29 publications, 26.85%
|
|
|
Journal of Prosthetic Dentistry
17 publications, 15.74%
|
|
|
Dental Materials
6 publications, 5.56%
|
|
|
Applied Sciences (Switzerland)
4 publications, 3.7%
|
|
|
Journal of Prosthodontics
4 publications, 3.7%
|
|
|
Materials
3 publications, 2.78%
|
|
|
Journal of Prosthodontic Research
3 publications, 2.78%
|
|
|
Journal of Esthetic and Restorative Dentistry
3 publications, 2.78%
|
|
|
Journal of the Mechanical Behavior of Biomedical Materials
3 publications, 2.78%
|
|
|
Prosthesis
3 publications, 2.78%
|
|
|
BMC Oral Health
3 publications, 2.78%
|
|
|
Additive Manufacturing
2 publications, 1.85%
|
|
|
Biomimetics
2 publications, 1.85%
|
|
|
Polymers
2 publications, 1.85%
|
|
|
Clinical Implant Dentistry and Related Research
1 publication, 0.93%
|
|
|
Dentistry Journal
1 publication, 0.93%
|
|
|
European Journal of General Dentistry
1 publication, 0.93%
|
|
|
Journal of Dental Sciences
1 publication, 0.93%
|
|
|
Journal of Advanced Prosthodontics
1 publication, 0.93%
|
|
|
Scientific Reports
1 publication, 0.93%
|
|
|
Journal of Biological Engineering
1 publication, 0.93%
|
|
|
Journal of Manufacturing Processes
1 publication, 0.93%
|
|
|
Journal of Materials Research and Technology
1 publication, 0.93%
|
|
|
Applied Materials Today
1 publication, 0.93%
|
|
|
Advances in Applied Ceramics
1 publication, 0.93%
|
|
|
Journal of International Oral Health
1 publication, 0.93%
|
|
|
Journal of the European Ceramic Society
1 publication, 0.93%
|
|
|
Journal of Korean Acedemy of Dental Technology
1 publication, 0.93%
|
|
|
International Materials Reviews
1 publication, 0.93%
|
|
|
5
10
15
20
25
30
|
Publishers
|
10
20
30
40
50
60
70
|
|
|
Elsevier
66 publications, 61.11%
|
|
|
MDPI
16 publications, 14.81%
|
|
|
Wiley
8 publications, 7.41%
|
|
|
Springer Nature
8 publications, 7.41%
|
|
|
Ovid Technologies (Wolters Kluwer Health)
2 publications, 1.85%
|
|
|
Japan Prosthodontic Society
2 publications, 1.85%
|
|
|
SAGE
2 publications, 1.85%
|
|
|
Association for Dental Sciences of the Republic of China
1 publication, 0.93%
|
|
|
The Korean Academy of prosthodontics
1 publication, 0.93%
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
1 publication, 0.93%
|
|
|
Korean Academy of Dental Technology
1 publication, 0.93%
|
|
|
10
20
30
40
50
60
70
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
108
Total citations:
108
Citations from 2024:
72
(66.67%)
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Lerner H. et al. Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study // Journal of Dentistry. 2021. Vol. 113. p. 103792.
GOST all authors (up to 50)
Copy
Lerner H., Nagy K., Pranno N., Zarone F., Admakin O., Mangano F. G. Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study // Journal of Dentistry. 2021. Vol. 113. p. 103792.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.jdent.2021.103792
UR - https://doi.org/10.1016/j.jdent.2021.103792
TI - Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study
T2 - Journal of Dentistry
AU - Lerner, Henriette
AU - Nagy, Katalin
AU - Pranno, Nicola
AU - Zarone, Fernando
AU - Admakin, Oleg
AU - Mangano, Francesco Guido
PY - 2021
DA - 2021/10/01
PB - Elsevier
SP - 103792
VL - 113
PMID - 34481929
SN - 0300-5712
SN - 2345-6485
SN - 2345-6418
SN - 1879-176X
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2021_Lerner,
author = {Henriette Lerner and Katalin Nagy and Nicola Pranno and Fernando Zarone and Oleg Admakin and Francesco Guido Mangano},
title = {Trueness and precision of 3D-printed versus milled monolithic zirconia crowns: An in vitro study},
journal = {Journal of Dentistry},
year = {2021},
volume = {113},
publisher = {Elsevier},
month = {oct},
url = {https://doi.org/10.1016/j.jdent.2021.103792},
pages = {103792},
doi = {10.1016/j.jdent.2021.103792}
}