Abstract
Metronidazole (MTZ) is a broad-spectrum antibiotic with numerous routes of administration, including topical. Topical application of MTZ gel or cream results in very low systemic absorption, resulting in the need for a sensitive extraction method to quantify plasma concentrations. Currently published methods are not suitable for analysis of plasma concentrations after topical application, as undetectable MTZ concentrations commonly occur. We validated a simple extraction method for MTZ recovery from plasma and quantified it using an LC-MS/MS analytical method. Methods: Plasma samples were spiked with MTZ (0.5 – 5 ng/mL) and internal standard (tinidazole, 2 ng/mL). MTZ was extracted by liquid-liquid extraction using ethyl acetate and acetonitrile mixture (4:1) as the extraction solvent. A quadrupole mass spectrometer interfaced with an Acquity H-Class HPLC was used to quantify MTZ concentrations in positive ion mode. A Kinetix C18 analytical column (150 mm × 4.6 mm i.d., 5 μm particle size) was used for separation. The plasma extraction method was validated for various parameters, including % recovery, precision, accuracy, and stability. Results: The extraction method demonstrated high MTZ recovery, ranging from 93.7 – 97.5%. The calibration curve prepared using MTZ samples extracted from plasma (0.5 – 5 ng/mL) had excellent linearity with R2 = 0.999. The extracted samples also showed higher autosampler and freeze-thaw stability over a 72-hr period. The mean intra- and inter-day accuracy and precision of the extraction assay ranged from 97 to 101.6%. and 2.7 – 4.8% RSD, respectively. The assay was highly efficient, with a limit of quantification (0.53 ± 0.04 ng/mL) lower than previously published methods (≥5 ng/mL). The extraction method was successfully validated using LC-MS/MS and can be used to extract and detect trace amounts of MTZ in plasma after topical application.
Found 

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
0
Share
Cite this
GOST |
Cite this
GOST Copy
Patel K. K. et al. Validation of a sensitive bioanalytical method for metronidazole extraction from human plasma // Journal of Pharmaceutical and Biomedical Analysis Open. 2024. Vol. 3. p. 100025.
GOST all authors (up to 50) Copy
Patel K. K., Cota V., Brogden N. K. Validation of a sensitive bioanalytical method for metronidazole extraction from human plasma // Journal of Pharmaceutical and Biomedical Analysis Open. 2024. Vol. 3. p. 100025.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1016/j.jpbao.2024.100025
UR - https://linkinghub.elsevier.com/retrieve/pii/S2949771X2400001X
TI - Validation of a sensitive bioanalytical method for metronidazole extraction from human plasma
T2 - Journal of Pharmaceutical and Biomedical Analysis Open
AU - Patel, Krishna Kumar
AU - Cota, Valeria
AU - Brogden, Nicole K
PY - 2024
DA - 2024/06/01
PB - Elsevier
SP - 100025
VL - 3
PMID - 39582498
SN - 2949-771X
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2024_Patel,
author = {Krishna Kumar Patel and Valeria Cota and Nicole K Brogden},
title = {Validation of a sensitive bioanalytical method for metronidazole extraction from human plasma},
journal = {Journal of Pharmaceutical and Biomedical Analysis Open},
year = {2024},
volume = {3},
publisher = {Elsevier},
month = {jun},
url = {https://linkinghub.elsevier.com/retrieve/pii/S2949771X2400001X},
pages = {100025},
doi = {10.1016/j.jpbao.2024.100025}
}