volume 102 issue 8 pages 1061-1068

Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications

Romain Gaillard 1
S Lustig 1
A. Peltier 1
V. VILLA 1
E. Servien 1
P. Neyret 1
1
 
Service d’orthopédie, Albert-Trillat Center, hôpital de la Croix-Rousse, 103, grande rue de la Croix-Rousse, 69004 Lyon, France
Publication typeJournal Article
Publication date2016-12-01
scimago Q1
wos Q2
SJR1.354
CiteScore5.5
Impact factor2.2
ISSN18770568
Surgery
Orthopedics and Sports Medicine
Abstract
Despite excellent long-term outcomes, posterior stabilisation by a third condyle continues to receive unwarranted criticism regarding patellar complications and instability. Complication rates with a tri-condylar posterior-stabilised implant are similar to those with other posterior-stabilised prostheses and have diminished over time due to improvements in prosthesis design. Post-operative complications and revision rates were assessed retrospectively in a prospective cohort of 4189 consecutive patients who had primary total knee arthroplasty (TKA) using a tri-condylar posterior-stabilised implant (Wright-Tornier) and were then followed-up for at least 24 months. The analysis included 2844 knees. The prosthesis generations were HLS1 ® , n = 20; HLS2 ® , n = 220; HLS Evolution ® , n = 636; HLS Noetos ® , n = 1373; and HLS KneeTec ® , n = 595. Complications were compared across generations by applying Fisher's exact test, and survival was compared using the Kaplan-Meier method. At last follow-up, there had been 341 (12%) post-operative complications in 306 (10.8%) knees, including 168 (5.9%) related to the implant, 41 (1.4%) infections, and 132 (4.6%) secondary complications unrelated to the implant. Re-operation was required for 200 complications (7%), including 87 (3.1%) consisting in revision of the prosthesis. Implant-related complications were stiffness ( n = 67, 2.4%), patellar fracture ( n = 34, 1.2%), patellar clunk syndrome ( n = 25, 0.9%), patellar loosening ( n = 3, 0.1%), tibial/femoral loosening ( n = 15, 0.5%), polyethylene wear ( n = 3, 0.1%), and implant rupture ( n = 1, 0.04%). Significant differences across generations were found for stiffness ( P < 0.0001), patellar fracture ( P = 0.03), clunk syndrome ( P = 0.03), and polyethylene wear ( P = 0.004), whose frequencies declined from one generation to the next. Overall 10-year survival was 92% with no significant difference across generations ( P = 0.1). Outcomes of tri-condylar posterior-stabilised TKA are similar to those obtained using other posterior-stabilised implants. Neither patellar complications nor instability are more common, and improvements in implant design have contributed to correct early flaws. IV, historical cohort, retrospective assessment of prospectively collected data.
Found 
Found 

Top-30

Journals

1
2
3
4
5
6
7
8
Knee Surgery, Sports Traumatology, Arthroscopy
8 publications, 30.77%
Orthopaedics and Traumatology: Surgery and Research
4 publications, 15.38%
Journal of Arthroplasty
3 publications, 11.54%
Revue de Chirurgie Orthopedique et Traumatologique
3 publications, 11.54%
3D Printing and Additive Manufacturing
1 publication, 3.85%
Journal of Materials Research and Technology
1 publication, 3.85%
Materials Today: Proceedings
1 publication, 3.85%
Additive Manufacturing
1 publication, 3.85%
Zeitschrift fur Orthopadie und Unfallchirurgie
1 publication, 3.85%
Bone & Joint Open
1 publication, 3.85%
Archives of Orthopaedic and Trauma Surgery
1 publication, 3.85%
SICOT-J
1 publication, 3.85%
1
2
3
4
5
6
7
8

Publishers

2
4
6
8
10
12
14
Elsevier
13 publications, 50%
Springer Nature
9 publications, 34.62%
Mary Ann Liebert
1 publication, 3.85%
Georg Thieme Verlag KG
1 publication, 3.85%
British Editorial Society of Bone and Joint Surgery
1 publication, 3.85%
EDP Sciences
1 publication, 3.85%
2
4
6
8
10
12
14
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
26
Share
Cite this
GOST |
Cite this
GOST Copy
Gaillard R. et al. Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications // Orthopaedics and Traumatology: Surgery and Research. 2016. Vol. 102. No. 8. pp. 1061-1068.
GOST all authors (up to 50) Copy
Gaillard R., Lustig S., Peltier A., VILLA V., Servien E., Neyret P. Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications // Orthopaedics and Traumatology: Surgery and Research. 2016. Vol. 102. No. 8. pp. 1061-1068.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1016/j.otsr.2016.08.015
UR - https://doi.org/10.1016/j.otsr.2016.08.015
TI - Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications
T2 - Orthopaedics and Traumatology: Surgery and Research
AU - Gaillard, Romain
AU - Lustig, S
AU - Peltier, A.
AU - VILLA, V.
AU - Servien, E.
AU - Neyret, P.
PY - 2016
DA - 2016/12/01
PB - Elsevier
SP - 1061-1068
IS - 8
VL - 102
PMID - 27771429
SN - 1877-0568
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2016_Gaillard,
author = {Romain Gaillard and S Lustig and A. Peltier and V. VILLA and E. Servien and P. Neyret},
title = {Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications},
journal = {Orthopaedics and Traumatology: Surgery and Research},
year = {2016},
volume = {102},
publisher = {Elsevier},
month = {dec},
url = {https://doi.org/10.1016/j.otsr.2016.08.015},
number = {8},
pages = {1061--1068},
doi = {10.1016/j.otsr.2016.08.015}
}
MLA
Cite this
MLA Copy
Gaillard, Romain, et al. “Total knee implant posterior stabilised by a third condyle: Design evolution and post-operative complications.” Orthopaedics and Traumatology: Surgery and Research, vol. 102, no. 8, Dec. 2016, pp. 1061-1068. https://doi.org/10.1016/j.otsr.2016.08.015.