Journal of Prosthetic Dentistry, volume 125, issue 4, pages 603-610

Marginal adaptation of zirconia complete-coverage fixed dental restorations made from digital scans or conventional impressions: A systematic review and meta-analysis

Mahtab Tabesh 1
Farahnaz Nejatidanesh 2
Ghazal Savabi 3
Amin Davoudi 4
Omid Savabi 5
Hesam Mirmohammadi 6
Publication typeJournal Article
Publication date2021-04-01
scimago Q1
SJR1.177
CiteScore7.0
Impact factor4.3
ISSN00223913, 10976841
Oral Surgery
Abstract

Abstract

Statement of problem

Intraoral scanners have been increasingly used in recent years. However, the accuracy of digital scans as it affects marginal adaptation is unclear.

Purpose

The purpose of this systematic review and meta-analysis was to compare the marginal adaptation of single-unit zirconia crowns fabricated with digital scans or with conventional impressions.

Material and methods

The electronic databases PubMed (MEDLINE), Cochrane Central Register of Controlled Trials (CENTRAL), Web of Science (ISI), Scopus, and EMBASE were searched and complemented by a manual search. Risks of bias were assessed by using a modified methodological index for nonrandomized studies (MINORS). Mean ±standard deviation (SD) values of marginal accuracy of studies were extracted for both methods. Mean marginal difference and 95% confidence interval (CI) were calculated to evaluate the marginal accuracy of each method. Pooled data were statistically analyzed by using a random-effect model.

Results

Seventeen studies were used to perform the meta-analysis. Subgroup analysis was performed based on intraoral scanners. Standardized mean marginal difference and 95% CI of each subgroup were as follows: Lava: -0.85 μm (95% CI: -1.67, -0.03) (P=.043); CEREC: -1.32 μm (95% CI: -2.06, -0.59) (P<.001); iTero: -0.44 μm (95% CI: -1.35, 0.47) (P=.338); TRIOS: -1.26 μm (95% CI: -2.02, -0.51) (P=.001); unknown scanner: -0.21 μm (95% CI: -1.14, 0.72); all studies: -0.89 μm (95% CI: -1.24, -0.54) (P<.001).

Conclusions

Digital scanning of prepared teeth for single-unit zirconia restorations resulted in better marginal accuracy than conventional techniques using elastomeric impression materials.
Found 
Found 

Top-30

Journals

5
10
15
20
25
5
10
15
20
25

Publishers

5
10
15
20
25
30
35
5
10
15
20
25
30
35
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex | MLA
Found error?