Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure
Publication type: Journal Article
Publication date: 2023-08-01
scimago Q1
wos Q1
SJR: 1.625
CiteScore: 10.4
Impact factor: 6.6
ISSN: 02638231, 18793223
Mechanical Engineering
Building and Construction
Civil and Structural Engineering
Abstract
Technological advances in the development of steel–concrete composite structures have led to the introduction of novel types of sections in the sought of higher load-bearing capacities. Particularly for composite columns, the axial capacity of concrete-filled steel tubular (CFST) sections may be enhanced by the introduction of an open steel profile embedded within the concrete infill, forming the so-called steel-reinforced concrete-filled steel tubular (SR-CFST) columns. An important aspect that should be revised, in order to safely use these sections in design, is their performance after a fire. In this experimental program, six SR-CFST stub columns are tested in the post-fire situation. Two series of columns comprising three circular and three square sections with the same steel usage are tested for comparison purposes. The size of the inner steel profile is varied in order to investigate its effect over the post-fire capacity of the columns. The specimens were initially exposed to elevated temperatures inside an electric furnace, and then cooled to ambient temperature; afterwards compressive axial load was applied gradually until failure, to ascertain their residual capacity. The experimental results show the high ductility of the SR-CFST stub columns after heating, with the circular specimens reaching higher post-fire peak loads than their square counterparts. This load increases with the size of the embedded steel profile. The post-fire capacities of the columns are evaluated through the Residual Strength Index, showing similar values for both circular and square SR-CFST columns. Finally, a design equation is proposed to facilitate the evaluation of the post-fire compression resistance of SR-CFST columns, as an extension of the existing room temperature design equation in Eurocode 4 Part 1–2 for CFST columns, accounting for the degradation of the steel and concrete after fire exposure through the corresponding residual factors.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
3
|
|
|
Thin-Walled Structures
3 publications, 17.65%
|
|
|
Structures
3 publications, 17.65%
|
|
|
Engineering Structures
3 publications, 17.65%
|
|
|
Journal of Building Engineering
2 publications, 11.76%
|
|
|
Fire Technology
1 publication, 5.88%
|
|
|
Journal of Constructional Steel Research
1 publication, 5.88%
|
|
|
Reviews on Advanced Materials Science
1 publication, 5.88%
|
|
|
Innovative Infrastructure Solutions
1 publication, 5.88%
|
|
|
Case Studies in Construction Materials
1 publication, 5.88%
|
|
|
Cleaner Waste Systems
1 publication, 5.88%
|
|
|
1
2
3
|
Publishers
|
2
4
6
8
10
12
14
|
|
|
Elsevier
14 publications, 82.35%
|
|
|
Springer Nature
2 publications, 11.76%
|
|
|
Walter de Gruyter
1 publication, 5.88%
|
|
|
2
4
6
8
10
12
14
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
17
Total citations:
17
Citations from 2024:
14
(82.36%)
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Medall D. et al. Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure // Thin-Walled Structures. 2023. Vol. 189. p. 110900.
GOST all authors (up to 50)
Copy
Medall D., Ibáñez C., Albero V., Espinós A., Romero M. L. Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure // Thin-Walled Structures. 2023. Vol. 189. p. 110900.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.tws.2023.110900
UR - https://doi.org/10.1016/j.tws.2023.110900
TI - Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure
T2 - Thin-Walled Structures
AU - Medall, D.
AU - Ibáñez, Carmen
AU - Albero, V.
AU - Espinós, A.
AU - Romero, M. L.
PY - 2023
DA - 2023/08/01
PB - Elsevier
SP - 110900
VL - 189
SN - 0263-8231
SN - 1879-3223
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2023_Medall,
author = {D. Medall and Carmen Ibáñez and V. Albero and A. Espinós and M. L. Romero},
title = {Experimental residual capacity of steel-reinforced concrete-filled steel tubular stub columns after fire exposure},
journal = {Thin-Walled Structures},
year = {2023},
volume = {189},
publisher = {Elsevier},
month = {aug},
url = {https://doi.org/10.1016/j.tws.2023.110900},
pages = {110900},
doi = {10.1016/j.tws.2023.110900}
}