Characterization of Ultrasound Propagation Through Ex-vivo Human Temporal Bone
Azzdine Y. Ammi
1
,
T.D. Mast
1
,
I-Hua Huang
2
,
Todd A. Abruzzo
2
,
Constantin-C Coussios
3
,
George H. Shaw
4
,
C K Holland
2
3
[Department of Engineering Science, Institute of Biomedical Engineering, Oxford, UK]
|
Publication type: Journal Article
Publication date: 2008-10-01
scimago Q1
wos Q2
SJR: 0.663
CiteScore: 4.9
Impact factor: 2.6
ISSN: 03015629, 1879291X
PubMed ID:
18456391
Biophysics
Radiological and Ultrasound Technology
Acoustics and Ultrasonics
Radiology, Nuclear Medicine and imaging
Abstract
Adjuvant therapies that lower the thrombolytic dose or increase its efficacy would represent a significant breakthrough in the treatment of patients with ischemic stroke. The objective of this study was to perform intracranial measurements of the acoustic pressure field generated by 0.12, 1.03 and 2.00-MHz ultrasound transducers to identify optimal ultrasound parameters that would maximize penetration and minimize aberration of the beam. To achieve this goal, in vitro experiments were conducted on five human skull specimens. In a water-filled tank, two unfocused transducers (0.12 and 1.03 MHz) and one focused transducer (2.00 MHz) were consecutively placed near the right temporal bone of each skull. A hydrophone, mounted on a micropositioning system, was moved to an estimated location of the middle cerebral artery (MCA) origin, and measurements of the surrounding acoustic pressure field were performed. For each measurement, the distance from the position of maximum acoustic pressure to the estimated origin of the MCA inside the skulls was quantified. The -3 dB depth-of-field and beamwidth in the skull were also investigated as a function of the three frequencies. Results show that the transducer alignment relative to the skull is a significant determinant of the detailed behavior of the acoustic field inside the skull. For optimal penetration, insonation normal to the temporal bone was needed. The shape of the 0.12-MHz intracranial beam was more distorted than those at 1.03 and 2.00 MHz because of the large aperture and beamwidth. However, lower ultrasound pressure reduction was observed at 0.12 MHz (22.5%). At 1.03 and 2.00 MHz, two skulls had an insufficient temporal bone window and attenuated the beam severely (up to 96.6% pressure reduction). For all frequencies, constructive and destructive interference patterns were seen near the contralateral skull wall at various elevations. The 0.12-MHz ultrasound beam depth-of-field was affected the most when passing through the temporal bone and showed a decrease in size of more than 55% on average. The speed of sound in the temporal bone of each skull was estimated at 1.03 MHz and demonstrated a large range (1752.1 to 3285.3 m/s). Attenuation coefficients at 1.03 and 2.00 MHz were also derived for each of the five skull specimens. This work provides needed information on ultrasound beam shapes inside the human skull, which is a necessary first step for the development of an optimal transcranial ultrasound-enhanced thrombolysis device.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
2
4
6
8
10
12
14
|
|
|
Ultrasound in Medicine and Biology
14 publications, 17.07%
|
|
|
Physics in Medicine and Biology
7 publications, 8.54%
|
|
|
Ultrasonics
6 publications, 7.32%
|
|
|
IEEE Transactions on Biomedical Engineering
5 publications, 6.1%
|
|
|
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
5 publications, 6.1%
|
|
|
International Journal of Hyperthermia
3 publications, 3.66%
|
|
|
Journal of the Acoustical Society of America
2 publications, 2.44%
|
|
|
Scientific Reports
2 publications, 2.44%
|
|
|
PLoS ONE
2 publications, 2.44%
|
|
|
Journal of Stroke and Cerebrovascular Diseases
2 publications, 2.44%
|
|
|
Stroke
1 publication, 1.22%
|
|
|
Sensors
1 publication, 1.22%
|
|
|
Frontiers in Neurology
1 publication, 1.22%
|
|
|
Frontiers in Neuroscience
1 publication, 1.22%
|
|
|
Nature Biotechnology
1 publication, 1.22%
|
|
|
Journal of Neuro-Oncology
1 publication, 1.22%
|
|
|
Translational Stroke Research
1 publication, 1.22%
|
|
|
Pharmacology and Therapeutics
1 publication, 1.22%
|
|
|
Journal of Thrombosis and Thrombolysis
1 publication, 1.22%
|
|
|
BMC Neurology
1 publication, 1.22%
|
|
|
Journal of Investigative Dermatology
1 publication, 1.22%
|
|
|
Advanced Drug Delivery Reviews
1 publication, 1.22%
|
|
|
Veterinary Medicine and Science
1 publication, 1.22%
|
|
|
Journal of Clinical Ultrasound
1 publication, 1.22%
|
|
|
Acoustical Physics
1 publication, 1.22%
|
|
|
Advances in Experimental Medicine and Biology
1 publication, 1.22%
|
|
|
Expert Opinion on Drug Delivery
1 publication, 1.22%
|
|
|
IEEE Transactions on Biomedical Circuits and Systems
1 publication, 1.22%
|
|
|
Physical Review Applied
1 publication, 1.22%
|
|
|
2
4
6
8
10
12
14
|
Publishers
|
5
10
15
20
25
30
|
|
|
Elsevier
27 publications, 32.93%
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
15 publications, 18.29%
|
|
|
Springer Nature
9 publications, 10.98%
|
|
|
IOP Publishing
7 publications, 8.54%
|
|
|
Taylor & Francis
4 publications, 4.88%
|
|
|
MDPI
3 publications, 3.66%
|
|
|
Acoustical Society of America (ASA)
2 publications, 2.44%
|
|
|
Frontiers Media S.A.
2 publications, 2.44%
|
|
|
Public Library of Science (PLoS)
2 publications, 2.44%
|
|
|
Wiley
2 publications, 2.44%
|
|
|
Cold Spring Harbor Laboratory
2 publications, 2.44%
|
|
|
Ovid Technologies (Wolters Kluwer Health)
1 publication, 1.22%
|
|
|
Pleiades Publishing
1 publication, 1.22%
|
|
|
American Physical Society (APS)
1 publication, 1.22%
|
|
|
AME Publishing Company
1 publication, 1.22%
|
|
|
American Chemical Society (ACS)
1 publication, 1.22%
|
|
|
5
10
15
20
25
30
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
82
Total citations:
82
Citations from 2024:
12
(14.64%)
Cite this
GOST |
RIS |
BibTex |
MLA
Cite this
GOST
Copy
Ammi A. Y. et al. Characterization of Ultrasound Propagation Through Ex-vivo Human Temporal Bone // Ultrasound in Medicine and Biology. 2008. Vol. 34. No. 10. pp. 1578-1589.
GOST all authors (up to 50)
Copy
Ammi A. Y., Mast T., Huang I., Abruzzo T. A., Coussios C., Shaw G. H., Holland C. K. Characterization of Ultrasound Propagation Through Ex-vivo Human Temporal Bone // Ultrasound in Medicine and Biology. 2008. Vol. 34. No. 10. pp. 1578-1589.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.ultrasmedbio.2008.02.012
UR - https://doi.org/10.1016/j.ultrasmedbio.2008.02.012
TI - Characterization of Ultrasound Propagation Through Ex-vivo Human Temporal Bone
T2 - Ultrasound in Medicine and Biology
AU - Ammi, Azzdine Y.
AU - Mast, T.D.
AU - Huang, I-Hua
AU - Abruzzo, Todd A.
AU - Coussios, Constantin-C
AU - Shaw, George H.
AU - Holland, C K
PY - 2008
DA - 2008/10/01
PB - Elsevier
SP - 1578-1589
IS - 10
VL - 34
PMID - 18456391
SN - 0301-5629
SN - 1879-291X
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2008_Ammi,
author = {Azzdine Y. Ammi and T.D. Mast and I-Hua Huang and Todd A. Abruzzo and Constantin-C Coussios and George H. Shaw and C K Holland},
title = {Characterization of Ultrasound Propagation Through Ex-vivo Human Temporal Bone},
journal = {Ultrasound in Medicine and Biology},
year = {2008},
volume = {34},
publisher = {Elsevier},
month = {oct},
url = {https://doi.org/10.1016/j.ultrasmedbio.2008.02.012},
number = {10},
pages = {1578--1589},
doi = {10.1016/j.ultrasmedbio.2008.02.012}
}
Cite this
MLA
Copy
Ammi, Azzdine Y., et al. “Characterization of Ultrasound Propagation Through Ex-vivo Human Temporal Bone.” Ultrasound in Medicine and Biology, vol. 34, no. 10, Oct. 2008, pp. 1578-1589. https://doi.org/10.1016/j.ultrasmedbio.2008.02.012.