volume 1271 pages 341465

Faraday cage-type ECL biosensor for the detection of circulating tumor cell MCF-7

Publication typeJournal Article
Publication date2023-08-01
scimago Q1
wos Q1
SJR1.004
CiteScore10.4
Impact factor6.0
ISSN00032670, 18734324
Biochemistry
Spectroscopy
Analytical Chemistry
Environmental Chemistry
Abstract
Herein, a Faraday cage-type electrochemiluminescence biosensor was designed for the detection of human breast cancer cell MCF-7. Two kinds of nanomaterials, Fe3O4-APTs and GO@PTCA-APTs, were synthesized as capture unit and signal unit, respectively. In presence of the target MCF-7, the Faraday cage-type electrochemiluminescence biosensor was constructed by forming a complex "capture unit-MCF-7-signal unit". In this case, lots of electrochemiluminescence signal probes were assembled and could participate in the electrode reaction, achieving a significant increase in sensitivity. In addition, the double aptamer recognition strategy was adopted to improve the capture, enrichment efficiency and detection reliability. Under optimal experimental conditions, the limit of detection was 3 cells/mL. And, the sensor could afford the detection of actual human blood samples, which is the first report on the detection of intact circulating tumor cells by the Faraday cage-type electrochemiluminescence biosensor.
Found 
Found 

Top-30

Journals

1
2
RSC Advances
2 publications, 20%
Advanced Functional Materials
1 publication, 10%
Chemical Engineering Journal
1 publication, 10%
Materials Today Chemistry
1 publication, 10%
Food Chemistry
1 publication, 10%
Analytical Chemistry
1 publication, 10%
Electrochimica Acta
1 publication, 10%
Chemical Engineering Science
1 publication, 10%
Russian Chemical Reviews
1 publication, 10%
1
2

Publishers

1
2
3
4
5
Elsevier
5 publications, 50%
Royal Society of Chemistry (RSC)
2 publications, 20%
Wiley
1 publication, 10%
American Chemical Society (ACS)
1 publication, 10%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 publication, 10%
1
2
3
4
5
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
10
Share
Cite this
GOST |
Cite this
GOST Copy
Zhang J. et al. Faraday cage-type ECL biosensor for the detection of circulating tumor cell MCF-7 // Analytica Chimica Acta. 2023. Vol. 1271. p. 341465.
GOST all authors (up to 50) Copy
Zhang J., Zhou H., Hao T., Yang Y., Zhang Q., Li J., Meng Y. L., Wu Y., Gao W., Guo Z. Faraday cage-type ECL biosensor for the detection of circulating tumor cell MCF-7 // Analytica Chimica Acta. 2023. Vol. 1271. p. 341465.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1016/j.aca.2023.341465
UR - https://doi.org/10.1016/j.aca.2023.341465
TI - Faraday cage-type ECL biosensor for the detection of circulating tumor cell MCF-7
T2 - Analytica Chimica Acta
AU - Zhang, Jie
AU - Zhou, Huiqian
AU - Hao, Tingting
AU - Yang, Yiming
AU - Zhang, Qingqing
AU - Li, Jinyun
AU - Meng, Y. L.
AU - Wu, Yangbo
AU - Gao, Wanlei
AU - Guo, Zhiyong
PY - 2023
DA - 2023/08/01
PB - Elsevier
SP - 341465
VL - 1271
PMID - 37328246
SN - 0003-2670
SN - 1873-4324
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2023_Zhang,
author = {Jie Zhang and Huiqian Zhou and Tingting Hao and Yiming Yang and Qingqing Zhang and Jinyun Li and Y. L. Meng and Yangbo Wu and Wanlei Gao and Zhiyong Guo},
title = {Faraday cage-type ECL biosensor for the detection of circulating tumor cell MCF-7},
journal = {Analytica Chimica Acta},
year = {2023},
volume = {1271},
publisher = {Elsevier},
month = {aug},
url = {https://doi.org/10.1016/j.aca.2023.341465},
pages = {341465},
doi = {10.1016/j.aca.2023.341465}
}
Profiles