P-benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals
Publication type: Journal Article
Publication date: 2013-03-01
scimago Q1
wos Q1
SJR: 2.007
CiteScore: 20.9
Impact factor: 10.5
ISSN: 09565663, 18734235
PubMed ID:
23062555
General Medicine
Biophysics
Electrochemistry
Biotechnology
Biomedical Engineering
Abstract
A rapid and reliable p-benzoquinone-mediated amperometric biosensor (ToxTell) incorporated with Psychrobacter sp. to detect toxicities of heavy metal ions has been developed. This ToxTell biosensor relied on the real-time monitoring of inhibition effect for metabolism by toxicant to provide early detection and assessment of the degree of toxicity to living cells. The effect of growth phase on the sensitivity of Psychrobacter sp. biosensor was studied. The results showed that at the middle of the logarithmic phase or transition from logarithmic to stationary phase, the Psychrobacter sp. ToxTell biosensor had a higher sensitivity to toxicants. The effects of pH, salinity in respiratory substrates and incubation time on the performance of Psychrobacter sp. biosensor were also investigated. EC(50) values of Cu(2+), Cd(2+), Zn(2+), Cr(6+), Hg(2+) and Pb(2+) to Psychrobacter sp. determined at incubation time 30 min were 2.6 mg/L, 47.3 mg/L, 10.9 mg/L, 14.0 mg/L, 0.8 mg/L and 110.1 mg/L, respectively. The ToxTell microbial biosensor developed in this work demonstrated excellent storage stability for more than 60 days. The biosensor could incorporate different microbial species as biocomponent to reflect the comprehensive values for toxicants in real samples and the results therefore had high degree of validity.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
3
4
|
|
|
Chemosphere
4 publications, 6.9%
|
|
|
Talanta
4 publications, 6.9%
|
|
|
The Analyst
4 publications, 6.9%
|
|
|
Journal of Hazardous Materials
3 publications, 5.17%
|
|
|
Biosensors and Bioelectronics
3 publications, 5.17%
|
|
|
Sensors and Actuators, B: Chemical
3 publications, 5.17%
|
|
|
Analytical and Bioanalytical Chemistry
2 publications, 3.45%
|
|
|
Electrochimica Acta
2 publications, 3.45%
|
|
|
ACS Sensors
2 publications, 3.45%
|
|
|
Water Science and Technology
1 publication, 1.72%
|
|
|
Royal Society Open Science
1 publication, 1.72%
|
|
|
Applied Sciences (Switzerland)
1 publication, 1.72%
|
|
|
Sensors
1 publication, 1.72%
|
|
|
Applied Biochemistry and Biotechnology
1 publication, 1.72%
|
|
|
Environmental Monitoring and Assessment
1 publication, 1.72%
|
|
|
Environments - MDPI
1 publication, 1.72%
|
|
|
Journal of Electroanalytical Chemistry
1 publication, 1.72%
|
|
|
Colloids and Surfaces A: Physicochemical and Engineering Aspects
1 publication, 1.72%
|
|
|
Journal of Microbiological Methods
1 publication, 1.72%
|
|
|
Analytica Chimica Acta
1 publication, 1.72%
|
|
|
Enzyme and Microbial Technology
1 publication, 1.72%
|
|
|
Journal of Molecular Liquids
1 publication, 1.72%
|
|
|
Journal of Power Sources
1 publication, 1.72%
|
|
|
ChemElectroChem
1 publication, 1.72%
|
|
|
Advanced Materials
1 publication, 1.72%
|
|
|
ACS applied materials & interfaces
1 publication, 1.72%
|
|
|
Analytical Chemistry
1 publication, 1.72%
|
|
|
RSC Advances
1 publication, 1.72%
|
|
|
Acta Agriculturae Slovenica
1 publication, 1.72%
|
|
|
1
2
3
4
|
Publishers
|
5
10
15
20
25
30
|
|
|
Elsevier
29 publications, 50%
|
|
|
Springer Nature
7 publications, 12.07%
|
|
|
MDPI
5 publications, 8.62%
|
|
|
Royal Society of Chemistry (RSC)
5 publications, 8.62%
|
|
|
American Chemical Society (ACS)
4 publications, 6.9%
|
|
|
Wiley
2 publications, 3.45%
|
|
|
IWA Publishing
1 publication, 1.72%
|
|
|
The Royal Society
1 publication, 1.72%
|
|
|
University of Ljubljana
1 publication, 1.72%
|
|
|
Cold Spring Harbor Laboratory
1 publication, 1.72%
|
|
|
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 publication, 1.72%
|
|
|
5
10
15
20
25
30
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
58
Total citations:
58
Citations from 2025:
2
(3.45%)
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Wang X. et al. P-benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals // Biosensors and Bioelectronics. 2013. Vol. 41. pp. 557-562.
GOST all authors (up to 50)
Copy
Wang X., Liu M., Wang X., Wu Z., Yang L., Xia S., Chen L., ZHAO J. P-benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals // Biosensors and Bioelectronics. 2013. Vol. 41. pp. 557-562.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1016/j.bios.2012.09.020
UR - https://doi.org/10.1016/j.bios.2012.09.020
TI - P-benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals
T2 - Biosensors and Bioelectronics
AU - Wang, Xuejiang
AU - Liu, Mian
AU - Wang, Xin
AU - Wu, Zhen
AU - Yang, Lianzhen
AU - Xia, Siqing
AU - Chen, Ling
AU - ZHAO, JIANFU
PY - 2013
DA - 2013/03/01
PB - Elsevier
SP - 557-562
VL - 41
PMID - 23062555
SN - 0956-5663
SN - 1873-4235
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2013_Wang,
author = {Xuejiang Wang and Mian Liu and Xin Wang and Zhen Wu and Lianzhen Yang and Siqing Xia and Ling Chen and JIANFU ZHAO},
title = {P-benzoquinone-mediated amperometric biosensor developed with Psychrobacter sp. for toxicity testing of heavy metals},
journal = {Biosensors and Bioelectronics},
year = {2013},
volume = {41},
publisher = {Elsevier},
month = {mar},
url = {https://doi.org/10.1016/j.bios.2012.09.020},
pages = {557--562},
doi = {10.1016/j.bios.2012.09.020}
}