Biosensors and Bioelectronics, volume 102, pages 80-86

Robust immunosensing system based on biotin-streptavidin coupling for spatially localized femtogram mL−1 level detection of interleukin-6

Publication typeJournal Article
Publication date2018-04-01
Quartile SCImago
Q1
Quartile WOS
Q1
Impact factor12.6
ISSN09565663, 18734235
General Medicine
Biophysics
Electrochemistry
Biotechnology
Biomedical Engineering
Abstract
Detection of a very low amount of cytokines such as interleukin-6 (IL-6) in clinical fluids is important in biomedical research and clinical applications. Here, we demonstrate spatially-localized ultrasensitive (femtogram mL-1) level detection of IL-6 in serum and in cell culture media. Our approach is based on a sandwich immunosensor fabricated on the surface of an optical fibre. Firstly, the biotinylated IL-6 capture antibody was immobilized on the fibre surface by biotin-streptavidin coupling. Then the fabricated fibre was used for capturing IL-6 followed by exposure to detection antibody which was labeled with the fluorescent magnetic nanoparticles to report the signal. A linear relationship between IL-6 concentration and the fluorescence signal was obtained in the range from 0.4pgmL-1 to 400pgmL-1 of IL-6, with the limit of detection down to 0.1pgmL-1. In addition, this optical fibre sensor was successfully applied for the localized detection of IL-6 with the spatial resolution of 200µm and a sample volume of 1µL. Finally, the performance of the fibre sensor was demonstrated by detection of IL-6 secreted by BV-2 cells with comparable performance of the conventional enzyme-linked immunosorbent assay (ELISA).

Top-30

Citations by journals

1
2
3
4
5
6
Biosensors and Bioelectronics
6 publications, 9.84%
Sensors and Actuators, B: Chemical
5 publications, 8.2%
Biosensors
3 publications, 4.92%
Talanta
3 publications, 4.92%
Microchimica Acta
2 publications, 3.28%
Analytica Chimica Acta
2 publications, 3.28%
Bioelectrochemistry
2 publications, 3.28%
ACS Applied Bio Materials
2 publications, 3.28%
Analytical Chemistry
2 publications, 3.28%
New Journal of Chemistry
2 publications, 3.28%
APL Photonics
1 publication, 1.64%
Frontiers in Bioengineering and Biotechnology
1 publication, 1.64%
Sensors
1 publication, 1.64%
Photonics
1 publication, 1.64%
Sensing and Bio-Sensing Research
1 publication, 1.64%
Clinica Chimica Acta
1 publication, 1.64%
Materials Today Communications
1 publication, 1.64%
Talanta Open
1 publication, 1.64%
Brain, Behavior, and Immunity
1 publication, 1.64%
Journal of Colloid and Interface Science
1 publication, 1.64%
Journal of Electroanalytical Chemistry
1 publication, 1.64%
Dyes and Pigments
1 publication, 1.64%
Advanced Science
1 publication, 1.64%
ACS Sensors
1 publication, 1.64%
ACS applied materials & interfaces
1 publication, 1.64%
ACS Omega
1 publication, 1.64%
RSC Advances
1 publication, 1.64%
The Analyst
1 publication, 1.64%
Molecular Systems Design and Engineering
1 publication, 1.64%
1
2
3
4
5
6

Citations by publishers

5
10
15
20
25
30
Elsevier
28 publications, 45.9%
American Chemical Society (ACS)
8 publications, 13.11%
Royal Society of Chemistry (RSC)
6 publications, 9.84%
Multidisciplinary Digital Publishing Institute (MDPI)
5 publications, 8.2%
Wiley
3 publications, 4.92%
IEEE
3 publications, 4.92%
Springer Nature
2 publications, 3.28%
Taylor & Francis
2 publications, 3.28%
American Institute of Physics (AIP)
1 publication, 1.64%
Frontiers Media S.A.
1 publication, 1.64%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 publication, 1.64%
5
10
15
20
25
30
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
Share
Cite this
GOST |
Cite this
GOST Copy
Zhang K. et al. Robust immunosensing system based on biotin-streptavidin coupling for spatially localized femtogram mL−1 level detection of interleukin-6 // Biosensors and Bioelectronics. 2018. Vol. 102. pp. 80-86.
GOST all authors (up to 50) Copy
Zhang K., Liu G., Goldys E. M. Robust immunosensing system based on biotin-streptavidin coupling for spatially localized femtogram mL−1 level detection of interleukin-6 // Biosensors and Bioelectronics. 2018. Vol. 102. pp. 80-86.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1016/j.bios.2017.11.023
UR - https://doi.org/10.1016/j.bios.2017.11.023
TI - Robust immunosensing system based on biotin-streptavidin coupling for spatially localized femtogram mL−1 level detection of interleukin-6
T2 - Biosensors and Bioelectronics
AU - Zhang, Kaixin
AU - Liu, Guozhen
AU - Goldys, Ewa M.
PY - 2018
DA - 2018/04/01 00:00:00
PB - Elsevier
SP - 80-86
VL - 102
SN - 0956-5663
SN - 1873-4235
ER -
BibTex
Cite this
BibTex Copy
@article{2018_Zhang,
author = {Kaixin Zhang and Guozhen Liu and Ewa M. Goldys},
title = {Robust immunosensing system based on biotin-streptavidin coupling for spatially localized femtogram mL−1 level detection of interleukin-6},
journal = {Biosensors and Bioelectronics},
year = {2018},
volume = {102},
publisher = {Elsevier},
month = {apr},
url = {https://doi.org/10.1016/j.bios.2017.11.023},
pages = {80--86},
doi = {10.1016/j.bios.2017.11.023}
}
Found error?