Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes
Тип публикации: Journal Article
Дата публикации: 2011-12-01
SCImago Q1
WOS Q2
БС1
SJR: 0.954
CiteScore: 9.5
Impact factor: 5.8
ISSN: 00134686, 18733859
General Chemical Engineering
Electrochemistry
Краткое описание
We recently presented a calcium-selective thin-layer coulometric system in view of realizing recalibration free ion sensors. A multi-pulse protocol allowing for a significant background current correction was further modified here by a numerical evaluation of the electrolysis end-point. A potassium-selective system was studied here within the 10 μM to 1 mM KCl concentration range with a 10 mM LiCl as a background solution. A residual 20 nA s −1 signal change was used to indicate the end of exhaustive ion transfer from the sample across the ion-selective membrane. Optimized electrolysis times were found from 13.4 s for a 10 μM sample to 270 s for a 1 mM sample. The intercept of the calibration curve of observed ion transfer charge vs. concentration was found to be just 2.3 ± 2.0 μC. The observed slope of 1.18 ± 0.02 C M −1 was very similar to the one calculated based on the known volume of the sample, 1.19 ± 0.12 C M −1 , suggesting that the method is promising as an absolute measurement tool.
Найдено
Ничего не найдено, попробуйте изменить настройки фильтра.
Для доступа к списку цитирований публикации необходимо авторизоваться.
Топ-30
Журналы
|
1
2
3
4
5
6
7
|
|
|
Analytical Chemistry
7 публикаций, 53.85%
|
|
|
Russian Chemical Reviews
1 публикация, 7.69%
|
|
|
Talanta
1 публикация, 7.69%
|
|
|
Accounts of Chemical Research
1 публикация, 7.69%
|
|
|
ACS Measurement Science Au
1 публикация, 7.69%
|
|
|
Applied Sciences (Switzerland)
1 публикация, 7.69%
|
|
|
1
2
3
4
5
6
7
|
Издатели
|
1
2
3
4
5
6
7
8
9
|
|
|
American Chemical Society (ACS)
9 публикаций, 69.23%
|
|
|
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 публикация, 7.69%
|
|
|
Elsevier
1 публикация, 7.69%
|
|
|
MDPI
1 публикация, 7.69%
|
|
|
1
2
3
4
5
6
7
8
9
|
- Мы не учитываем публикации, у которых нет DOI.
- Статистика публикаций обновляется еженедельно.
Вы ученый?
Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Войти с ORCID
Метрики
13
Всего цитирований:
13
Цитирований c 2025:
2
(15.38%)
Цитировать
ГОСТ |
RIS |
BibTex |
MLA
Цитировать
ГОСТ
Скопировать
Grygolowicz-Pawlak E., Bakker E. Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes // Electrochimica Acta. 2011. Vol. 56. No. 28. pp. 10359-10363.
ГОСТ со всеми авторами (до 50)
Скопировать
Grygolowicz-Pawlak E., Bakker E. Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes // Electrochimica Acta. 2011. Vol. 56. No. 28. pp. 10359-10363.
Цитировать
RIS
Скопировать
TY - JOUR
DO - 10.1016/j.electacta.2011.02.053
UR - https://doi.org/10.1016/j.electacta.2011.02.053
TI - Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes
T2 - Electrochimica Acta
AU - Grygolowicz-Pawlak, Ewa
AU - Bakker, Eric
PY - 2011
DA - 2011/12/01
PB - Elsevier
SP - 10359-10363
IS - 28
VL - 56
SN - 0013-4686
SN - 1873-3859
ER -
Цитировать
BibTex (до 50 авторов)
Скопировать
@article{2011_Grygolowicz-Pawlak,
author = {Ewa Grygolowicz-Pawlak and Eric Bakker},
title = {Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes},
journal = {Electrochimica Acta},
year = {2011},
volume = {56},
publisher = {Elsevier},
month = {dec},
url = {https://doi.org/10.1016/j.electacta.2011.02.053},
number = {28},
pages = {10359--10363},
doi = {10.1016/j.electacta.2011.02.053}
}
Цитировать
MLA
Скопировать
Grygolowicz-Pawlak, Ewa, and Eric Bakker. “Thin layer coulometry ion sensing protocol with potassium-selective membrane electrodes.” Electrochimica Acta, vol. 56, no. 28, Dec. 2011, pp. 10359-10363. https://doi.org/10.1016/j.electacta.2011.02.053.
Ошибка в публикации?