Operational Improvement of a Proton Therapy System from Reduced Energy Layer Switching Time

Тип публикацииJournal Article
Дата публикации2025-06-01
SCImago Q2
WOS Q3
БС3
SJR0.627
CiteScore4.5
Impact factor2
ISSN23315180
Краткое описание
This study reports the potential operational improvement provided by reduced energy layer switching time and total beam delivery time of a 3-room IBA ProteusPLUS system. Eight treatment fields, including various disease sites and a reference cube, were analyzed for energy layer switching time and total delivery time before and after an energy layer switching time upgrade. The upgraded beam delivery time estimated the total treatment capacity for a 12-h treatment day using a 3-room system with a single common cyclotron. The potential increase in revenue was estimated using Medicare reimbursement rates for proton therapy intermediate. The average layer switching time was reduced from 6.33 to 1.86 s, reducing the average field delivery time from 240 to 113 s. Overall, the average energy layer switching time reduction was 70.6%, and the average total treatment field delivery time was reduced by 52.6%. Head and neck cancer fields experienced the greatest treatment time reduction of 59.5%, reducing from 236 to 95.5 s. The treatment field delivery time reduction allowed an increase from 60 to 127 patients per day, an increase of 112%. Reductions in energy layer switching time significantly decreased treatment field delivery time. Reduced treatment field delivery time may provide clinical benefits to patients through improved patient alignment and comfort. Increased treatment capacity could also improve patient access to proton therapy for disease sites that may experience clinical benefits, such as head and neck cancer.
Для доступа к списку цитирований публикации необходимо авторизоваться.

Топ-30

Журналы

1
Journal of the Franklin Institute
1 публикация, 100%
1

Издатели

1
Elsevier
1 публикация, 100%
1
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
2
Поделиться
Цитировать
ГОСТ |
Цитировать
Artz M. et al. Operational Improvement of a Proton Therapy System from Reduced Energy Layer Switching Time // International Journal of Particle Therapy. 2025. Vol. 16. p. 100742.
ГОСТ со всеми авторами (до 50) Скопировать
Artz M., Grewal H. S., Zhang Y., Johnson P. B., Saki M., Schreuder N., Brooks E. D., Park J. Operational Improvement of a Proton Therapy System from Reduced Energy Layer Switching Time // International Journal of Particle Therapy. 2025. Vol. 16. p. 100742.
RIS |
Цитировать
TY - JOUR
DO - 10.1016/j.ijpt.2025.100742
UR - https://linkinghub.elsevier.com/retrieve/pii/S2331518025000058
TI - Operational Improvement of a Proton Therapy System from Reduced Energy Layer Switching Time
T2 - International Journal of Particle Therapy
AU - Artz, Mark
AU - Grewal, Hardev S
AU - Zhang, Yawei
AU - Johnson, Perry B
AU - Saki, Mohammad
AU - Schreuder, Niek
AU - Brooks, Eric D.
AU - Park, Jiyeon
PY - 2025
DA - 2025/06/01
PB - Elsevier
SP - 100742
VL - 16
SN - 2331-5180
ER -
BibTex
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2025_Artz,
author = {Mark Artz and Hardev S Grewal and Yawei Zhang and Perry B Johnson and Mohammad Saki and Niek Schreuder and Eric D. Brooks and Jiyeon Park},
title = {Operational Improvement of a Proton Therapy System from Reduced Energy Layer Switching Time},
journal = {International Journal of Particle Therapy},
year = {2025},
volume = {16},
publisher = {Elsevier},
month = {jun},
url = {https://linkinghub.elsevier.com/retrieve/pii/S2331518025000058},
pages = {100742},
doi = {10.1016/j.ijpt.2025.100742}
}
Ошибка в публикации?