том 205 издание 2 страницы 247-254

Continuous flow Overhauser dynamic nuclear polarization of water in the fringe field of a clinical magnetic resonance imaging system for authentic image contrast

Тип публикацииJournal Article
Дата публикации2010-08-01
scimago Q2
wos Q2
БС1
SJR0.554
CiteScore4.2
Impact factor1.9
ISSN10907807, 10960856
Biochemistry
Biophysics
Condensed Matter Physics
Nuclear and High Energy Physics
Краткое описание
We describe and demonstrate a system to generate hyperpolarized water in the 0.35 T fringe field of a clinical 1.5 T whole-body magnetic resonance imaging (MRI) magnet. Once generated, the hyperpolarized water is quickly and continuously transferred from the 0.35 T fringe to the 1.5 T center field of the same magnet for image acquisition using standard MRI equipment. The hyperpolarization is based on Overhauser dynamic nuclear polarization (DNP), which effectively and quickly transfers the higher spin polarization of free radicals to nuclear spins at ambient temperatures. We visualize the dispersion of hyperpolarized water as it flows through water-saturated systems by utilizing an observed -15-fold DNP signal enhancement with respect to the unenhanced (1)H MRI signal of water at 1.5 T. The experimental DNP apparatus presented here is readily portable and can be brought to and used with any conventional unshielded MRI system. A new method of immobilizing radicals to gel beads via polyelectrolyte linker arms is described, which led to superior flow Overhauser DNP performance compared to previously presented gels. We discuss the general applicability of Overhauser DNP of water and aqueous solutions in the fringe field of commercially available magnets with central fields up to 4.7 T.
Найдено 
Для доступа к списку цитирований публикации необходимо авторизоваться.

Топ-30

Журналы

1
2
3
4
5
6
Journal of Magnetic Resonance
6 публикаций, 13.64%
Magnetic Resonance in Chemistry
3 публикации, 6.82%
Advances in Magnetic Resonance Technology and Applications
3 публикации, 6.82%
Topics in Current Chemistry
2 публикации, 4.55%
Review of Scientific Instruments
2 публикации, 4.55%
Radiology
2 публикации, 4.55%
Applied Magnetic Resonance
2 публикации, 4.55%
Progress in Nuclear Magnetic Resonance Spectroscopy
2 публикации, 4.55%
Analytical Chemistry
2 публикации, 4.55%
Physical Chemistry Chemical Physics
2 публикации, 4.55%
Annual Reports on NMR Spectroscopy
2 публикации, 4.55%
Sensors
1 публикация, 2.27%
Molecules
1 публикация, 2.27%
Scientific Reports
1 публикация, 2.27%
Solid State Nuclear Magnetic Resonance
1 публикация, 2.27%
Mendeleev Communications
1 публикация, 2.27%
Magnetic Resonance in Medicine
1 публикация, 2.27%
ChemPhysChem
1 публикация, 2.27%
NMR in Biomedicine
1 публикация, 2.27%
Biochemistry
1 публикация, 2.27%
Journal of Physical Chemistry C
1 публикация, 2.27%
ACS Applied Nano Materials
1 публикация, 2.27%
Chemical Science
1 публикация, 2.27%
Journal of Liposome Research
1 публикация, 2.27%
Zeitschrift fur Physikalische Chemie
1 публикация, 2.27%
Journal of Magnetic Resonance Open
1 публикация, 2.27%
1
2
3
4
5
6

Издатели

2
4
6
8
10
12
14
16
Elsevier
15 публикаций, 34.09%
Wiley
6 публикаций, 13.64%
Springer Nature
5 публикаций, 11.36%
American Chemical Society (ACS)
5 публикаций, 11.36%
Royal Society of Chemistry (RSC)
3 публикации, 6.82%
AIP Publishing
2 публикации, 4.55%
Radiological Society of North America (RSNA)
2 публикации, 4.55%
MDPI
2 публикации, 4.55%
OOO Zhurnal "Mendeleevskie Soobshcheniya"
1 публикация, 2.27%
Taylor & Francis
1 публикация, 2.27%
De Gruyter Brill
1 публикация, 2.27%
2
4
6
8
10
12
14
16
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
44
Поделиться
Цитировать
ГОСТ |
Цитировать
Lingwood M. D. et al. Continuous flow Overhauser dynamic nuclear polarization of water in the fringe field of a clinical magnetic resonance imaging system for authentic image contrast // Journal of Magnetic Resonance. 2010. Vol. 205. No. 2. pp. 247-254.
ГОСТ со всеми авторами (до 50) Скопировать
Lingwood M. D., Siaw T. A., Sailasuta N., ROSS B., Bhattacharya P., Han S. Continuous flow Overhauser dynamic nuclear polarization of water in the fringe field of a clinical magnetic resonance imaging system for authentic image contrast // Journal of Magnetic Resonance. 2010. Vol. 205. No. 2. pp. 247-254.
RIS |
Цитировать
TY - JOUR
DO - 10.1016/j.jmr.2010.05.008
UR - https://doi.org/10.1016/j.jmr.2010.05.008
TI - Continuous flow Overhauser dynamic nuclear polarization of water in the fringe field of a clinical magnetic resonance imaging system for authentic image contrast
T2 - Journal of Magnetic Resonance
AU - Lingwood, Mark D.
AU - Siaw, Ting Ann
AU - Sailasuta, Napapon
AU - ROSS, B.
AU - Bhattacharya, Pratip
AU - Han, Shensheng
PY - 2010
DA - 2010/08/01
PB - Elsevier
SP - 247-254
IS - 2
VL - 205
PMID - 20541445
SN - 1090-7807
SN - 1096-0856
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2010_Lingwood,
author = {Mark D. Lingwood and Ting Ann Siaw and Napapon Sailasuta and B. ROSS and Pratip Bhattacharya and Shensheng Han},
title = {Continuous flow Overhauser dynamic nuclear polarization of water in the fringe field of a clinical magnetic resonance imaging system for authentic image contrast},
journal = {Journal of Magnetic Resonance},
year = {2010},
volume = {205},
publisher = {Elsevier},
month = {aug},
url = {https://doi.org/10.1016/j.jmr.2010.05.008},
number = {2},
pages = {247--254},
doi = {10.1016/j.jmr.2010.05.008}
}
MLA
Цитировать
Lingwood, Mark D., et al. “Continuous flow Overhauser dynamic nuclear polarization of water in the fringe field of a clinical magnetic resonance imaging system for authentic image contrast.” Journal of Magnetic Resonance, vol. 205, no. 2, Aug. 2010, pp. 247-254. https://doi.org/10.1016/j.jmr.2010.05.008.