Open Access
Open access
Photodiagnosis and Photodynamic Therapy, volume 46, pages 104043

Preoperative Evaluation of White Cataracts with the Pentacam

Güvenç Toprak 1
Alkan Yunus 2
Abdullah Bayrak 3
2
 
Specialist, Department of Ophthalmology, Mardin Derik State Hospital, 47800, Mardin, Turkey
3
 
Specialist, Macuria, Die Makulaxperten Augenpraxis, 88047, Meckenbeuren, Germany
Publication typeJournal Article
Publication date2024-04-01
scimago Q2
wos Q2
SJR0.718
CiteScore5.8
Impact factor3.1
ISSN15721000, 18731597
Oncology
Biophysics
Pharmacology (medical)
Dermatology
Abstract
To evaluate the use of the Pentacam to analyse the presence or absence of fluid pockets under the anterior capsule and their significance in terms of surgical management and prevention of complications.Abant İzzet Baysal University Hospital, Bolu, Turkey DESIGN: Randomized, masked, prospective design METHODS: 60 patients with mature cataracts underwent standard phacoemulsification (Phaco) and intraocular lens (IOL) implantation. Patients were divided into 3 groups. Group 1 underwent Phaco+IOL implantation without imaging by Pentacam. Group 2 had fluid detected in Pentacam imaging before the operation and underwent Phaco+IOL implantation with Brazilian method. Group 3 had no fluid detected in Pentacam imaging before the operation and underwent standart Phaco+IOL implantation operation.When the complication rates of 3 different groups were examined separately, they were found to be 15 % in group 1; 5 % in group 2 and 5 % in group 3, respectively. When compared in pairs as Group 1-2, 1-3, and 2-3, respectively (p < 0.01), (p < 0.01), (p > 0.05). The nuclear density of Group 2 and Group 3 was measured, resulting in 30.2 % and 29.6 %, respectively (P = 0.614). Lens thickness, patients with fluid (+) had a thickness of 5.35 mm, while patients with fluid (-) had a thickness of 3.96 mm (p < 0.05).Patients who are not imaged with pentacam before surgery experience more complications than other groups because the presence of fluid is unknown. Central lens thickness was higher in patients with fluid, and there was no significant difference in nuclear density between the groups with and without fluid. Pentacam can show the presence of supcapsular fluid and we recommend that imaging tools be more widely used in cataract surgery. We think that this will enable surgeons to make a more accurate surgical planning and reduce the risk of complications.
Found 

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex
Found error?