2D array design based on Fermat spiral for ultrasound imaging

Тип публикацииJournal Article
Дата публикации2010-02-01
SCImago Q1
Tоп 10% SCImago
WOS Q1
БС1
SJR1.087
CiteScore7.9
Impact factor4.1
ISSN0041624X, 18749968
Acoustics and Ultrasonics
Краткое описание
The main challenge faced by 3D ultrasonic imaging with 2D array transducers is the large number of elements required to achieve an acceptable level of quality in the images. Therefore, the optimisation of the array layout, in order to reduce the number of active elements in the aperture, has been a research topic in the last years. Nowadays, array technology has made viable the production of 2D arrays with larger flexibility on elements size, shape and position, allowing to study other configurations different to the classical matrix organisation, such as circular, archimedes spiral or polygonal layout between others. In this work, the problem of designing an imaging system array with large apertures and a very limited number of active elements (N(e)=128 and N(e)=256) using the Fermat spiral layout has been studied. As summary, a general discussion about the most interesting cases is presented.
Для доступа к списку цитирований публикации необходимо авторизоваться.

Топ-30

Журналы

2
4
6
8
10
12
14
16
18
20
IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
19 публикаций, 25.68%
Sensors
6 публикаций, 8.11%
IEEE Open Journal of Ultrasonics Ferroelectrics and Frequency Control
3 публикации, 4.05%
Journal of the Acoustical Society of America
2 публикации, 2.7%
Scientific Reports
2 публикации, 2.7%
Physics in Medicine and Biology
2 публикации, 2.7%
Ultrasonics
2 публикации, 2.7%
Russian Journal of Nondestructive Testing
2 публикации, 2.7%
IEEE Transactions on Biomedical Engineering
2 публикации, 2.7%
Signals and Communication Technology
2 публикации, 2.7%
Journal of Biomedical Optics
1 публикация, 1.35%
Micromachines
1 публикация, 1.35%
Solar Energy
1 публикация, 1.35%
Applied Acoustics
1 публикация, 1.35%
NDT and E International
1 публикация, 1.35%
Medical Physics
1 публикация, 1.35%
IEEE Journal of Oceanic Engineering
1 публикация, 1.35%
IEEE Transactions on Instrumentation and Measurement
1 публикация, 1.35%
IEEE Wireless Communications Letters
1 публикация, 1.35%
Engineering to Adapt
1 публикация, 1.35%
IFMBE Proceedings
1 публикация, 1.35%
Optics Express
1 публикация, 1.35%
Measurement Science and Technology
1 публикация, 1.35%
Measurement: Journal of the International Measurement Confederation
1 публикация, 1.35%
Structural Chemistry
1 публикация, 1.35%
Mechanical Systems and Signal Processing
1 публикация, 1.35%
Journal of the American Ceramic Society
1 публикация, 1.35%
Technologies
1 публикация, 1.35%
Radiology Cardiothoracic Imaging
1 публикация, 1.35%
2
4
6
8
10
12
14
16
18
20

Издатели

5
10
15
20
25
30
35
40
Institute of Electrical and Electronics Engineers (IEEE)
36 публикаций, 48.65%
MDPI
8 публикаций, 10.81%
Elsevier
7 публикаций, 9.46%
Springer Nature
6 публикаций, 8.11%
IOP Publishing
3 публикации, 4.05%
Wiley
3 публикации, 4.05%
Acoustical Society of America (ASA)
2 публикации, 2.7%
Pleiades Publishing
2 публикации, 2.7%
SPIE-Intl Soc Optical Eng
1 публикация, 1.35%
ifmbe proceedings
1 публикация, 1.35%
Optica Publishing Group
1 публикация, 1.35%
Radiological Society of North America (RSNA)
1 публикация, 1.35%
5
10
15
20
25
30
35
40
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
74
Поделиться
Цитировать
ГОСТ |
Цитировать
Martínez-Graullera Ó. et al. 2D array design based on Fermat spiral for ultrasound imaging // Ultrasonics. 2010. Vol. 50. No. 2. pp. 280-289.
ГОСТ со всеми авторами (до 50) Скопировать
Martínez-Graullera Ó., Martín C., Godoy G., Ullate L. G. 2D array design based on Fermat spiral for ultrasound imaging // Ultrasonics. 2010. Vol. 50. No. 2. pp. 280-289.
RIS |
Цитировать
TY - JOUR
DO - 10.1016/j.ultras.2009.09.010
UR - https://doi.org/10.1016/j.ultras.2009.09.010
TI - 2D array design based on Fermat spiral for ultrasound imaging
T2 - Ultrasonics
AU - Martínez-Graullera, Óscar
AU - Martín, C.
AU - Godoy, Gregorio
AU - Ullate, Luis G
PY - 2010
DA - 2010/02/01
PB - Elsevier
SP - 280-289
IS - 2
VL - 50
PMID - 19819510
SN - 0041-624X
SN - 1874-9968
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2010_Martínez-Graullera,
author = {Óscar Martínez-Graullera and C. Martín and Gregorio Godoy and Luis G Ullate},
title = {2D array design based on Fermat spiral for ultrasound imaging},
journal = {Ultrasonics},
year = {2010},
volume = {50},
publisher = {Elsevier},
month = {feb},
url = {https://doi.org/10.1016/j.ultras.2009.09.010},
number = {2},
pages = {280--289},
doi = {10.1016/j.ultras.2009.09.010}
}
MLA
Цитировать
Martínez-Graullera, Óscar, et al. “2D array design based on Fermat spiral for ultrasound imaging.” Ultrasonics, vol. 50, no. 2, Feb. 2010, pp. 280-289. https://doi.org/10.1016/j.ultras.2009.09.010.
Ошибка в публикации?