Gas-Powered and Portable Ventilators: An Evaluation of Six Models

Тип публикацииJournal Article
Дата публикации1992-03-01
SCImago Q1
WOS Q1
БС2
SJR0.851
CiteScore3.7
Impact factor2.5
ISSN1049023X, 19451938
Emergency Medicine
Emergency Nursing
Краткое описание
Introduction:

Gas-powered resuscitators (ventilators) designed to be used primarily for resuscitation should be basic and simple to use. They offer many advantages over manual methods of ventilation during in-hospital cardiopulmonary resuscitation. Portable ventilators intended for critical care transport require additional, more sophisticated features such as: adjustable pressure limiting valves, air-mixing, airway pressure gauge, independent tidal volume and rate controls, and a Positive End-Expiratory Pressure (PEEP) valve. The performance of six gas-powered resuscitators/portable ventilators (TransPAC, Oxylog, Ambu Matic, ERA 2000, Uni-Vent, and MARS) was evaluated.

Methods:

The accuracy of volumes delivered to a test lung at three different compliance and resistance settings, was assessed for each ventilator prior to clinical evaluation during cardio-pulmonary resuscitation (CPR) and patient transport.

Results:

In each circumstance, measured tidal volumes and levels of minute ventilation decreased as resistance was increased and compliance reduced. Much of this loss of measured tidal volume occurred through inspiratory pressure relief valves that tended to start leaking at pressures below the preset level. Increasing levels of back-pressure resulted in further reductions in tidal volume when the ventilators were tested using the air-mix mode (available on three of the devices). In general, each resuscitator functioned well when used during CPR within the hospital.

Conclusions:

Each resuscitator tested failed to deliver the preset volumes and this must be considered during their use. Inspiratory pressure relief valves for all but one of the ventilators tested would not permit the delivery of adequate levels of ventilation in patients with low pulmonary compliance and/or high airway resistance.

Для доступа к списку цитирований публикации необходимо авторизоваться.

Топ-30

Журналы

1
2
Resuscitation
2 публикации, 15.38%
Anaesthesia
2 публикации, 15.38%
Wilderness and Environmental Medicine
1 публикация, 7.69%
Circulation
1 публикация, 7.69%
Journal of Trauma and Acute Care Surgery
1 публикация, 7.69%
Baillière's Clinical Anaesthesiology
1 публикация, 7.69%
Journal of Air Medical Transport
1 публикация, 7.69%
Prehospital Emergency Care
1 публикация, 7.69%
Southern Medical Journal
1 публикация, 7.69%
Internal and Emergency Medicine
1 публикация, 7.69%
1
2

Издатели

1
2
3
4
5
6
Elsevier
6 публикаций, 46.15%
Ovid Technologies (Wolters Kluwer Health)
2 публикации, 15.38%
Wiley
2 публикации, 15.38%
Taylor & Francis
1 публикация, 7.69%
Southern Medical Association
1 публикация, 7.69%
Springer Nature
1 публикация, 7.69%
1
2
3
4
5
6
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
13
Поделиться
Цитировать
ГОСТ |
Цитировать
Nolan J. P., Baskett P. J. Gas-Powered and Portable Ventilators: An Evaluation of Six Models // Prehospital and Disaster Medicine. 1992. Vol. 7. No. 1. pp. 25-34.
ГОСТ со всеми авторами (до 50) Скопировать
Nolan J. P., Baskett P. J. Gas-Powered and Portable Ventilators: An Evaluation of Six Models // Prehospital and Disaster Medicine. 1992. Vol. 7. No. 1. pp. 25-34.
RIS |
Цитировать
TY - JOUR
DO - 10.1017/s1049023x00039169
UR - https://doi.org/10.1017/s1049023x00039169
TI - Gas-Powered and Portable Ventilators: An Evaluation of Six Models
T2 - Prehospital and Disaster Medicine
AU - Nolan, Jerry P.
AU - Baskett, Peter J.F.
PY - 1992
DA - 1992/03/01
PB - Cambridge University Press
SP - 25-34
IS - 1
VL - 7
PMID - 10149692
SN - 1049-023X
SN - 1945-1938
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{1992_Nolan,
author = {Jerry P. Nolan and Peter J.F. Baskett},
title = {Gas-Powered and Portable Ventilators: An Evaluation of Six Models},
journal = {Prehospital and Disaster Medicine},
year = {1992},
volume = {7},
publisher = {Cambridge University Press},
month = {mar},
url = {https://doi.org/10.1017/s1049023x00039169},
number = {1},
pages = {25--34},
doi = {10.1017/s1049023x00039169}
}
MLA
Цитировать
Nolan, Jerry P., and Peter J.F. Baskett. “Gas-Powered and Portable Ventilators: An Evaluation of Six Models.” Prehospital and Disaster Medicine, vol. 7, no. 1, Mar. 1992, pp. 25-34. https://doi.org/10.1017/s1049023x00039169.
Ошибка в публикации?