volume 25 issue 6 pages 2486-2492

Metasurface Plasmon Resonance Biosensor Enhanced with Dual Gold Nanoparticles for the Ultrasensitive Quantitative Detection of C-Reactive Protein

Youqian Chen 1, 2, 3, 4, 5
Yihui Yang 1, 2, 3, 4, 5
Hanlin Zhou 6, 7, 8
Han Lin Zhou 8
Wenshuai Yao 9, 10, 11
Wei Yao 11
Shaoqi Zeng 12, 13, 14, 15, 16
Mingqian Chen 4, 5
Wenjun Hu 1, 2, 3, 4, 5
Gang Logan Liu 1, 2, 3, 4, 5
Liping Huang 4, 5, 15, 16, 17
2
 
College of Life Science and Technology, State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases
3
 
Huazhong university of Science and Technology
4
 
College of Life Science and Technology, State Key Laboratory for Diagnosis and Treatment of Severe Zoonotic Infectious Diseases, Wuhan, China
10
 
School of Materials and Chemistry, China University of Geosciences
12
 
Biosensor R&D Department, Liangzhun (Wuhan) Life Technology Co., Ltd., Wuhan 430070, China
13
 
Biosensor R&D Department
14
 
Liangzhun (Wuhan) Life Technology Co., Ltd.
15
 
Biosensor R&D Department, Wuhan, China
16
 
Liangzhun (Wuhan) Life Technology Co., Ltd., Wuhan, China
Publication typeJournal Article
Publication date2025-01-28
scimago Q1
wos Q1
SJR2.967
CiteScore14.9
Impact factor9.1
ISSN15306984, 15306992
Abstract
The pursuit of cutting-edge diagnostic systems capable of detecting biomarkers with exceptional sensitivity and precision is crucial for the timely and accurate monitoring of inflammatory responses. In this study, we introduce a dual gold nanoparticle-enhanced metasurface plasmon resonance (Bi-MSPR) biosensor for the ultrasensitive detection of C-reactive protein (CRP). The Bi-MSPR sensor is constructed upon a nanocup array chip with gradient-free electron density, where an innovative metasurface structure is built using a PEI-immobilized dual-gold nanoparticle amplification system. This strategy greatly amplifies the local free electric field, resulting in a signal enhancement exceeding 10-fold, with a detection limit of 0.04 ng/mL for CRP in buffer solutions and 0.017 μg/mL for serum samples. Clinical validation demonstrates a 95.83% detection rate with no cross-reactivity, highlighting the sensor's remarkable specificity and sensitivity for CRP detection. The Bi-MSPR biosensor thus represents a rapid, sensitive, and specific diagnostic tool for CRP detection.
Found 
Found 

Top-30

Journals

1
ACS Nano
1 publication, 10%
Angewandte Chemie - International Edition
1 publication, 10%
Angewandte Chemie
1 publication, 10%
ACS Sensors
1 publication, 10%
Sensors and Actuators, B: Chemical
1 publication, 10%
Nano Letters
1 publication, 10%
Chemical Engineering Journal
1 publication, 10%
Microchemical Journal
1 publication, 10%
Journal of Materials Chemistry B
1 publication, 10%
Clinica Chimica Acta
1 publication, 10%
1

Publishers

1
2
3
4
Elsevier
4 publications, 40%
American Chemical Society (ACS)
3 publications, 30%
Wiley
2 publications, 20%
Royal Society of Chemistry (RSC)
1 publication, 10%
1
2
3
4
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
10
Share
Cite this
GOST |
Cite this
GOST Copy
Chen Y. et al. Metasurface Plasmon Resonance Biosensor Enhanced with Dual Gold Nanoparticles for the Ultrasensitive Quantitative Detection of C-Reactive Protein // Nano Letters. 2025. Vol. 25. No. 6. pp. 2486-2492.
GOST all authors (up to 50) Copy
Chen Y., Yang Y., Zhou H., Zhou H. L., Yao W., Yao W., Zeng S., Chen M., Hu W., Liu G. L., Huang L. Metasurface Plasmon Resonance Biosensor Enhanced with Dual Gold Nanoparticles for the Ultrasensitive Quantitative Detection of C-Reactive Protein // Nano Letters. 2025. Vol. 25. No. 6. pp. 2486-2492.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1021/acs.nanolett.4c06049
UR - https://pubs.acs.org/doi/10.1021/acs.nanolett.4c06049
TI - Metasurface Plasmon Resonance Biosensor Enhanced with Dual Gold Nanoparticles for the Ultrasensitive Quantitative Detection of C-Reactive Protein
T2 - Nano Letters
AU - Chen, Youqian
AU - Yang, Yihui
AU - Zhou, Hanlin
AU - Zhou, Han Lin
AU - Yao, Wenshuai
AU - Yao, Wei
AU - Zeng, Shaoqi
AU - Chen, Mingqian
AU - Hu, Wenjun
AU - Liu, Gang Logan
AU - Huang, Liping
PY - 2025
DA - 2025/01/28
PB - American Chemical Society (ACS)
SP - 2486-2492
IS - 6
VL - 25
SN - 1530-6984
SN - 1530-6992
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2025_Chen,
author = {Youqian Chen and Yihui Yang and Hanlin Zhou and Han Lin Zhou and Wenshuai Yao and Wei Yao and Shaoqi Zeng and Mingqian Chen and Wenjun Hu and Gang Logan Liu and Liping Huang},
title = {Metasurface Plasmon Resonance Biosensor Enhanced with Dual Gold Nanoparticles for the Ultrasensitive Quantitative Detection of C-Reactive Protein},
journal = {Nano Letters},
year = {2025},
volume = {25},
publisher = {American Chemical Society (ACS)},
month = {jan},
url = {https://pubs.acs.org/doi/10.1021/acs.nanolett.4c06049},
number = {6},
pages = {2486--2492},
doi = {10.1021/acs.nanolett.4c06049}
}
MLA
Cite this
MLA Copy
Chen, Youqian, et al. “Metasurface Plasmon Resonance Biosensor Enhanced with Dual Gold Nanoparticles for the Ultrasensitive Quantitative Detection of C-Reactive Protein.” Nano Letters, vol. 25, no. 6, Jan. 2025, pp. 2486-2492. https://pubs.acs.org/doi/10.1021/acs.nanolett.4c06049.