Microfluidic-Based Genosensor To Detect Human Papillomavirus (HPV16) for Head and Neck Cancer
Andrey Soares
1
,
Osvaldo NOVAIS DE Oliveira
1
,
Valquiria C. Rodrigues
1
,
Heveline Dal Magro Follmann
2
,
Lidia Maria Rebolho Batista Arantes
3
,
Ana Carolina Carvalho
3
,
Matias Eliseo Melendez
3
,
José Humberto T.G. Fregnani
3
,
Rui M. Reis
3, 4, 5
,
André Lopes Carvalho
3
,
3
Molecular Oncology Research Center, Barretos Cancer Hospital, 14784-400 Barretos, Brazil
|
5
ICVS/3B’s—PT Government Associate Laboratory, 4710-057 Braga, Portugal
|
Publication type: Journal Article
Publication date: 2018-10-08
Journal:
ACS applied materials & interfaces
scimago Q1
SJR: 2.058
CiteScore: 16.0
Impact factor: 8.3
ISSN: 19448244, 19448252
General Materials Science
Abstract
High-risk human papillomavirus (HPV) infection, mainly with HPV16 type, has been increasingly considered as an important etiologic factor in head and neck cancers. Detection of HPV16 is therefore crucial for these types of cancer, but clinical tests are not performed routinely in public health systems owing to the high cost and limitations of the existing tests. In this article, we report on a potentially low-cost genosensor capable of detecting low concentrations of HPV16 in buffer samples and distinguishing, with high accuracy, head and neck cancer cell lines according to their HPV16 status. The genosensor consisted of a microfluidic device that had an active layer of a HPV16 capture DNA probe (cpHPV16) deposited onto a layer-by-layer film of chitosan and chondroitin sulfate. Impedance spectroscopy was the principle of detection utilized, leading to a limit of detection of 10.5 pM for complementary ssDNA HPV16 oligos (ssHPV16). The genosensor was also able to distinguish among HPV16+ and HPV16- cell lines, using the multidimensional projection technique interactive document mapping. Hybridization between the ssHPV16 oligos and cpHPV16 probe was confirmed with polarization-modulated infrared reflection-absorption spectroscopy, where PO2 and amide I and amide II bands from adenine and thymine were monitored. The electrical response could be modeled as resulting from an adsorption process represented in a Freundlich model. Because the fabrication procedures of the microfluidic devices and genosensors and the data collection and analysis can be implemented at low cost, the results presented here amount to a demonstration of possible routine screening for HPV infections.