,  том 84 ,  издание 20 ,  страницы 8813-8821

Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode

Тип публикации: Journal Article
Дата публикации: 2012-10-04
SCImago Q1
Tоп 10% SCImago
WOS Q1
БС1
SJR: 1.358
CiteScore: 10.7
Impact factor: 7.3
ISSN: 00032700, 15206882, 21542686
Analytical Chemistry
Краткое описание
Ion-selective membranes based on porous polypropylene membranes doped with an ionophore and a lipophilic cation-exchanger are used here in a new tandem measurement mode that combines dynamic electrochemistry and zero current potentiometry into a single protocol. Open circuit potential measurements yield near-nernstian response slopes in complete analogy to established ion-selective electrode methodology. Such measurements are well established to give direct information on the so-called free ion concentration (strictly, activity) in the sample. The same membrane is here also operated in a constant current mode, in which the localized ion depletion at a transition time is visualized by chronopotentiometry. This dynamic electrochemistry methodology gives information on the labile ion concentration in the sample. The sequential protocol is established on potassium and calcium ion-selective membranes. An increase of the ionophore concentration in the membrane to 180 mM makes it possible to determine calcium concentrations as high as 3 mM by chronopotentiometry, thereby making it possible to directly detect total calcium in undiluted blood samples. Recovery times after current perturbation depend on the current amplitude but can be kept to below 1 min for the polypropylene based ion-selective membranes studied here. Plasticized PVC as membrane material is less suited for this protocol, especially when the measurement at elevated concentrations is desired. An analysis of current amplitudes, transition times, and concentrations shows that the data are described by the Sand equation and that migration effects are insignificant. A numerical model describes the experimental findings with good agreement and gives guidance on the required selectivity in order to observe a well-resolved transition time and on the expected errors due to insufficient selectivity. The simulations suggest that the methodology compares well to that of open circuit potentiometry, despite giving complementary information about the sample. The tandem methodology is demonstrated in a titration of calcium with nitrilotriacetic acid (NTA) and in the direct detection of calcium in undiluted heparinized and citrated blood.
Для доступа к списку цитирований публикации необходимо авторизоваться.

Топ-30

Журналы

1
2
3
4
5
6
7
Analytical Chemistry
7 публикаций, 17.95%
Sensors and Actuators, B: Chemical
5 публикаций, 12.82%
Electrochimica Acta
3 публикации, 7.69%
Analytica Chimica Acta
3 публикации, 7.69%
TrAC - Trends in Analytical Chemistry
2 публикации, 5.13%
Journal of Electroanalytical Chemistry
2 публикации, 5.13%
Biosensors
2 публикации, 5.13%
Applied Physics Letters
1 публикация, 2.56%
Analytical and Bioanalytical Chemistry
1 публикация, 2.56%
Microchimica Acta
1 публикация, 2.56%
Russian Chemical Reviews
1 публикация, 2.56%
Journal of Membrane Science
1 публикация, 2.56%
Biosensors and Bioelectronics
1 публикация, 2.56%
Biosensors and Bioelectronics: X
1 публикация, 2.56%
Electroanalysis
1 публикация, 2.56%
Accounts of Chemical Research
1 публикация, 2.56%
ACS Sensors
1 публикация, 2.56%
RSC Advances
1 публикация, 2.56%
Journal of Materials Chemistry B
1 публикация, 2.56%
Modeling Nanoscale Imaging in Electron Microscopy
1 публикация, 2.56%
Proceedings of the National Academy of Sciences of the United States of America
1 публикация, 2.56%
Nanomaterials
1 публикация, 2.56%
1
2
3
4
5
6
7

Издатели

2
4
6
8
10
12
14
16
18
Elsevier
18 публикаций, 46.15%
American Chemical Society (ACS)
9 публикаций, 23.08%
Springer Nature
3 публикации, 7.69%
MDPI
3 публикации, 7.69%
Royal Society of Chemistry (RSC)
2 публикации, 5.13%
AIP Publishing
1 публикация, 2.56%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 публикация, 2.56%
Wiley
1 публикация, 2.56%
Proceedings of the National Academy of Sciences (PNAS)
1 публикация, 2.56%
2
4
6
8
10
12
14
16
18
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
39
Поделиться
Цитировать
ГОСТ |
Цитировать
Ghahraman Afshar M., Crespo G. A., Bakker E. Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode // Analytical Chemistry. 2012. Vol. 84. No. 20. pp. 8813-8821.
ГОСТ со всеми авторами (до 50) Скопировать
Ghahraman Afshar M., Crespo G. A., Bakker E. Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode // Analytical Chemistry. 2012. Vol. 84. No. 20. pp. 8813-8821.
RIS |
Цитировать
TY - JOUR
DO - 10.1021/ac302092m
UR - https://doi.org/10.1021/ac302092m
TI - Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode
T2 - Analytical Chemistry
AU - Ghahraman Afshar, Majid
AU - Crespo, Gaston A
AU - Bakker, Eric
PY - 2012
DA - 2012/10/04
PB - American Chemical Society (ACS)
SP - 8813-8821
IS - 20
VL - 84
PMID - 22994137
SN - 0003-2700
SN - 1520-6882
SN - 2154-2686
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2012_Ghahraman Afshar,
author = {Majid Ghahraman Afshar and Gaston A Crespo and Eric Bakker},
title = {Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode},
journal = {Analytical Chemistry},
year = {2012},
volume = {84},
publisher = {American Chemical Society (ACS)},
month = {oct},
url = {https://doi.org/10.1021/ac302092m},
number = {20},
pages = {8813--8821},
doi = {10.1021/ac302092m}
}
MLA
Цитировать
Ghahraman Afshar, Majid, et al. “Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode.” Analytical Chemistry, vol. 84, no. 20, Oct. 2012, pp. 8813-8821. https://doi.org/10.1021/ac302092m.
Ошибка в публикации?