volume 38 issue 30 pages 9239-9246

Subnanomolar Detection of Mercury Cations in Water by an Interfacial Fluorescent Sensor Achieved by Ultrathin Film Structure Optimization

Publication typeJournal Article
Publication date2022-07-22
scimago Q1
wos Q2
SJR0.763
CiteScore6.0
Impact factor3.9
ISSN07437463, 15205827
Spectroscopy
Electrochemistry
Condensed Matter Physics
General Materials Science
Surfaces and Interfaces
Abstract
The objectives of this work were to develop and extend the previously proposed approaches to control the structure of nanoscale planar systems based on modular fluorophore compounds capable of efficient analyte binding and to optimize the architecture of ultrathin films formed from them to create a thin-film sensor element for mercury cations. The possibility of applying the ratiometric approach to the fluorescence measurements to obtain a quantitative analytical signal was shown. It was found that films with the Langmuir-Schaefer film architecture, in which the receptor crown ether groups of the fluoroionophore are oriented toward the studied solution, allow the quantitative determination of mercury cations in water at concentrations below the threshold limit value and are especially effective in the analyte concentration range of 10-10-10-5 M. High selectivity of the obtained thin-film sensitive elements with respect to mercury cations and the possibility of regeneration of such elements after quantitative determination of mercury cations in aqueous solutions are demonstrated.
Found 
Found 

Top-30

Journals

1
Coordination Chemistry Reviews
1 publication, 50%
Protection of Metals and Physical Chemistry of Surfaces
1 publication, 50%
1

Publishers

1
Elsevier
1 publication, 50%
Pleiades Publishing
1 publication, 50%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
2
Share
Cite this
GOST |
Cite this
GOST Copy
Aleksandrova A. et al. Subnanomolar Detection of Mercury Cations in Water by an Interfacial Fluorescent Sensor Achieved by Ultrathin Film Structure Optimization // Langmuir. 2022. Vol. 38. No. 30. pp. 9239-9246.
GOST all authors (up to 50) Copy
Aleksandrova A., Matyushenkova V., Shokurov A., Selektor S. L. Subnanomolar Detection of Mercury Cations in Water by an Interfacial Fluorescent Sensor Achieved by Ultrathin Film Structure Optimization // Langmuir. 2022. Vol. 38. No. 30. pp. 9239-9246.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1021/acs.langmuir.2c01012
UR - https://doi.org/10.1021/acs.langmuir.2c01012
TI - Subnanomolar Detection of Mercury Cations in Water by an Interfacial Fluorescent Sensor Achieved by Ultrathin Film Structure Optimization
T2 - Langmuir
AU - Aleksandrova, Alvina
AU - Matyushenkova, Victoria
AU - Shokurov, Alexander
AU - Selektor, Sofiya L.
PY - 2022
DA - 2022/07/22
PB - American Chemical Society (ACS)
SP - 9239-9246
IS - 30
VL - 38
PMID - 35867994
SN - 0743-7463
SN - 1520-5827
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2022_Aleksandrova,
author = {Alvina Aleksandrova and Victoria Matyushenkova and Alexander Shokurov and Sofiya L. Selektor},
title = {Subnanomolar Detection of Mercury Cations in Water by an Interfacial Fluorescent Sensor Achieved by Ultrathin Film Structure Optimization},
journal = {Langmuir},
year = {2022},
volume = {38},
publisher = {American Chemical Society (ACS)},
month = {jul},
url = {https://doi.org/10.1021/acs.langmuir.2c01012},
number = {30},
pages = {9239--9246},
doi = {10.1021/acs.langmuir.2c01012}
}
MLA
Cite this
MLA Copy
Aleksandrova, Alvina, et al. “Subnanomolar Detection of Mercury Cations in Water by an Interfacial Fluorescent Sensor Achieved by Ultrathin Film Structure Optimization.” Langmuir, vol. 38, no. 30, Jul. 2022, pp. 9239-9246. https://doi.org/10.1021/acs.langmuir.2c01012.