том 1 издание 4 страницы 1184-1194

Sensitive Chronocoulometric Detection of miRNA at Screen-Printed Electrodes Modified by Gold-Decorated MoS2 Nanosheets

Тип публикацииJournal Article
Дата публикации2018-09-10
Связанные публикации
SCImago Q1
WOS Q2
БС2
SJR0.909
CiteScore9
Impact factor4.7
ISSN25766422
General Chemistry
Biomaterials
Biomedical Engineering
Biochemistry (medical)
Краткое описание
Here a new chronocoulometric sensor, based on semiconducting 2H MoS2 nanosheets decorated with a controlled density of monodispersed small gold nanoparticles, was fabricated via electrodeposition, for the highly sensitive detection of miRNA-21. The size and interparticle spacing of AuNPs was optimized by controlling nucleation and growth rates through tuning of deposition-potential and Au-precursor concentration and by getting simultaneous feedback from morphological and electrochemical activity studies. The sensing strategy, involved the selective immobilization of thiolated capture probe DNA (CP) at AuNPs and hybridization of CP to a part of miRNA target, whereas the remaining part of the target was complementary to a signaling non-labelled DNA sequence. Chronocoulometry provided precise quantification of nucleic acids at each step of the sensor assay by interrogating [Ru(NH3)6]3+ electrostatically bound to phosphate backbones of oligonucleotides. A detailed and systematic optimization study demonstrated that the thinnest and smallest MoS2 NSs improved the sensitivity of the AuNP@MoS2 sensor achieving an impressive detection limit of 100 aM, which is 2 orders of magnitude lower than that of bare Au electrode and also enhanced the DNA-miRNA hybridization efficiency by 25%. Such improved performance can be attributed to the controlled packing density of CPs achieved by their self -assembly on AuNPs, large interparticle density, small size and the intimate coupling between AuNPs and MoS2. Alongside the outstanding sensitivity, the sensor exhibited excellent selectivity down to femtomolar concentrations, for discriminating complementary miRNA-21 target in a complex system composed of different foreign targets including mismatched and non-complementary miRNA-155. These advantages make our sensor a promising contender in the point of care miRNA sensor family for medical diagnostics.
Для доступа к списку цитирований публикации необходимо авторизоваться.
Для доступа к списку профилей, цитирующих публикацию, необходимо авторизоваться.

Топ-30

Журналы

1
2
3
Sensors and Actuators, B: Chemical
3 публикации, 7.5%
The Analyst
3 публикации, 7.5%
Talanta
2 публикации, 5%
RSC Advances
2 публикации, 5%
Advanced Materials Interfaces
2 публикации, 5%
Materials
1 публикация, 2.5%
Biosensors
1 публикация, 2.5%
Micromachines
1 публикация, 2.5%
Sensors
1 публикация, 2.5%
Microchimica Acta
1 публикация, 2.5%
Analytical and Bioanalytical Chemistry
1 публикация, 2.5%
Materials Today
1 публикация, 2.5%
Chemical Engineering Journal
1 публикация, 2.5%
Analytica Chimica Acta
1 публикация, 2.5%
Biosensors and Bioelectronics
1 публикация, 2.5%
Journal of Pharmaceutical and Biomedical Analysis
1 публикация, 2.5%
Electrochimica Acta
1 публикация, 2.5%
Analytical Biochemistry
1 публикация, 2.5%
Applied Surface Science
1 публикация, 2.5%
Microchemical Journal
1 публикация, 2.5%
Electrochemistry Communications
1 публикация, 2.5%
Applied Materials Today
1 публикация, 2.5%
Journal of Physical Chemistry C
1 публикация, 2.5%
ACS Applied Bio Materials
1 публикация, 2.5%
ACS Applied Electronic Materials
1 публикация, 2.5%
Analytical Methods
1 публикация, 2.5%
Analytical Chemistry
1 публикация, 2.5%
Russian Chemical Reviews
1 публикация, 2.5%
Chemosensors
1 публикация, 2.5%
Journal of the Electrochemical Society
1 публикация, 2.5%
1
2
3

Издатели

2
4
6
8
10
12
14
16
18
Elsevier
17 публикаций, 42.5%
Royal Society of Chemistry (RSC)
7 публикаций, 17.5%
MDPI
5 публикаций, 12.5%
American Chemical Society (ACS)
4 публикации, 10%
Springer Nature
3 публикации, 7.5%
Wiley
2 публикации, 5%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 публикация, 2.5%
The Electrochemical Society
1 публикация, 2.5%
2
4
6
8
10
12
14
16
18
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
40
Поделиться
Цитировать
ГОСТ |
Цитировать
Ganguly A., Benson J., Papakonstantinou P. Sensitive Chronocoulometric Detection of miRNA at Screen-Printed Electrodes Modified by Gold-Decorated MoS2 Nanosheets // ACS Applied Bio Materials. 2018. Vol. 1. No. 4. pp. 1184-1194.
ГОСТ со всеми авторами (до 50) Скопировать
Ganguly A., Benson J., Papakonstantinou P. Sensitive Chronocoulometric Detection of miRNA at Screen-Printed Electrodes Modified by Gold-Decorated MoS2 Nanosheets // ACS Applied Bio Materials. 2018. Vol. 1. No. 4. pp. 1184-1194.
RIS |
Цитировать
TY - JOUR
DO - 10.1021/acsabm.8b00398
UR - https://doi.org/10.1021/acsabm.8b00398
TI - Sensitive Chronocoulometric Detection of miRNA at Screen-Printed Electrodes Modified by Gold-Decorated MoS2 Nanosheets
T2 - ACS Applied Bio Materials
AU - Ganguly, Abhijit
AU - Benson, John
AU - Papakonstantinou, P.
PY - 2018
DA - 2018/09/10
PB - American Chemical Society (ACS)
SP - 1184-1194
IS - 4
VL - 1
PMID - 34996159
SN - 2576-6422
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2018_Ganguly,
author = {Abhijit Ganguly and John Benson and P. Papakonstantinou},
title = {Sensitive Chronocoulometric Detection of miRNA at Screen-Printed Electrodes Modified by Gold-Decorated MoS2 Nanosheets},
journal = {ACS Applied Bio Materials},
year = {2018},
volume = {1},
publisher = {American Chemical Society (ACS)},
month = {sep},
url = {https://doi.org/10.1021/acsabm.8b00398},
number = {4},
pages = {1184--1194},
doi = {10.1021/acsabm.8b00398}
}
MLA
Цитировать
Ganguly, Abhijit, et al. “Sensitive Chronocoulometric Detection of miRNA at Screen-Printed Electrodes Modified by Gold-Decorated MoS2 Nanosheets.” ACS Applied Bio Materials, vol. 1, no. 4, Sep. 2018, pp. 1184-1194. https://doi.org/10.1021/acsabm.8b00398.
Ошибка в публикации?