том 15 издание 31 страницы 37274-37289

Osteoconductive, Osteogenic, and Antipathogenic Plasma Electrolytic Oxidation Coatings on Titanium Implants with BMP-2

Тип публикацииJournal Article
Дата публикации2023-07-27
SCImago Q1
Tоп 10% SCImago
WOS Q1
БС1
SJR1.614
CiteScore14.5
Impact factor8.2
ISSN19448244, 19448252
General Materials Science
Краткое описание
We report a one-pot plasma electrolytic oxidation (PEO) strategy for forming a multi-element oxide layer on the titanium surface using complex electrolytes containing Na2HPO4, Ca(OH)2, (NH2)2CO, Na2SiO3, CuSO4, and KOH compounds. For even better bone implant ingrowth, PEO coatings were additionally loaded with bone morphogenetic protein-2 (BMP-2). The samples were tested in vivo in a mouse craniotomy model. Tests for bactericidal and fungicidal activity were carried out using clinically isolated multi-drug-resistant Escherichia coli (E. coli) K261, E. coli U20, methicillin-resistant Staphylococcus aureus (S. aureus) CSA154 bacterial strains, and Neurospora crassa (N. crassa) and Candida albicans (C. albicans) D2528/20 fungi. The PEO-Cu coating effectively inactivated both Gram-positive and Gram-negative bacteria at low concentrations of Cu2+ ions: minimal bactericidal concentration for E. coli and N. crassa (99.9999%) and minimal inhibitory concentration (99.0%) for S. aureus were 5 ppm. For all studied bacterial and fungal strains, PEO-Cu coating completely prevented the formation of bacterial and fungal biofilms. PEO and PEO-Cu coatings demonstrated bone remodeling and moderate osteoconductivity in vivo, while BMP-2 significantly enhanced osteoconduction and osteogenesis. The obtained results are encouraging and indicate that Ti-based materials with PEO coatings loaded with BMP-2 can be widely used in customized medicine as implants for orthopedics and cranio-maxillofacial surgery.
Для доступа к списку цитирований публикации необходимо авторизоваться.
Для доступа к списку профилей, цитирующих публикацию, необходимо авторизоваться.

Топ-30

Журналы

1
2
3
Applied Surface Science
3 публикации, 13.04%
Materials and Design
2 публикации, 8.7%
Surface and Coatings Technology
2 публикации, 8.7%
Materials
1 публикация, 4.35%
Coatings
1 публикация, 4.35%
Journal of Cluster Science
1 публикация, 4.35%
BMEMat
1 публикация, 4.35%
ACS Applied Bio Materials
1 публикация, 4.35%
ACS Biomaterials Science and Engineering
1 публикация, 4.35%
Bulletin of the Russian Academy of Sciences: Physics
1 публикация, 4.35%
Small
1 публикация, 4.35%
Nature Communications
1 публикация, 4.35%
Applied Biochemistry and Microbiology
1 публикация, 4.35%
ACS Applied Nano Materials
1 публикация, 4.35%
Nanomaterials
1 публикация, 4.35%
Bone Research
1 публикация, 4.35%
Russian Chemical Reviews
1 публикация, 4.35%
Materials Chemistry and Physics
1 публикация, 4.35%
Materials Today Bio
1 публикация, 4.35%
1
2
3

Издатели

1
2
3
4
5
6
7
8
9
Elsevier
9 публикаций, 39.13%
MDPI
3 публикации, 13.04%
Springer Nature
3 публикации, 13.04%
American Chemical Society (ACS)
3 публикации, 13.04%
Wiley
2 публикации, 8.7%
Pleiades Publishing
2 публикации, 8.7%
Autonomous Non-profit Organization Editorial Board of the journal Uspekhi Khimii
1 публикация, 4.35%
1
2
3
4
5
6
7
8
9
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
 Войти с ORCID
Метрики
23
Поделиться
Цитировать
ГОСТ |
Цитировать
Popova A. D. et al. Osteoconductive, Osteogenic, and Antipathogenic Plasma Electrolytic Oxidation Coatings on Titanium Implants with BMP-2 // ACS applied materials & interfaces. 2023. Vol. 15. No. 31. pp. 37274-37289.
ГОСТ со всеми авторами (до 50) Скопировать
Popova A. D., Sheveyko A. N., Kuptsov K. A., Advakhova D. Y., Karyagina A. S., Karyagina A. S., Gromov A. V., Gromov A. V., Krivozubov M. S., Orlova P. A., Volkov A. V., VOLKOV A. V., Slukin P. V., Slukin P. V., Ignatov S. G., Ignatov S., Shubina I. Z., Shubina I., Ilnitskaya A. S., Ilnitskaya A. S., Gloushankova N. A., Timoshenko R. V., Erofeev A. S., Erofeev A. V., Shtansky D. V. Osteoconductive, Osteogenic, and Antipathogenic Plasma Electrolytic Oxidation Coatings on Titanium Implants with BMP-2 // ACS applied materials & interfaces. 2023. Vol. 15. No. 31. pp. 37274-37289.
RIS |
Цитировать
TY - JOUR
DO - 10.1021/acsami.3c08954
UR - https://pubs.acs.org/doi/10.1021/acsami.3c08954
TI - Osteoconductive, Osteogenic, and Antipathogenic Plasma Electrolytic Oxidation Coatings on Titanium Implants with BMP-2
T2 - ACS applied materials & interfaces
AU - Popova, Anastasiya D.
AU - Sheveyko, Alexander N.
AU - Kuptsov, Konstantin A.
AU - Advakhova, Darya Yu.
AU - Karyagina, Anna S
AU - Karyagina, A. S.
AU - Gromov, Alexander V
AU - Gromov, A V
AU - Krivozubov, Mikhail S.
AU - Orlova, Polina A.
AU - Volkov, Alexey V
AU - VOLKOV, A V
AU - Slukin, Pavel V
AU - Slukin, P. V.
AU - Ignatov, Sergei G.
AU - Ignatov, S.G.
AU - Shubina, Irina Zh
AU - Shubina, Irina
AU - Ilnitskaya, Alla S
AU - Ilnitskaya, A. S.
AU - Gloushankova, N A
AU - Timoshenko, Roman V.
AU - Erofeev, Alexander S.
AU - Erofeev, Alexander V.
AU - Shtansky, Dmitry V.
PY - 2023
DA - 2023/07/27
PB - American Chemical Society (ACS)
SP - 37274-37289
IS - 31
VL - 15
PMID - 37499236
SN - 1944-8244
SN - 1944-8252
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2023_Popova,
author = {Anastasiya D. Popova and Alexander N. Sheveyko and Konstantin A. Kuptsov and Darya Yu. Advakhova and Anna S Karyagina and A. S. Karyagina and Alexander V Gromov and A V Gromov and Mikhail S. Krivozubov and Polina A. Orlova and Alexey V Volkov and A V VOLKOV and Pavel V Slukin and P. V. Slukin and Sergei G. Ignatov and S.G. Ignatov and Irina Zh Shubina and Irina Shubina and Alla S Ilnitskaya and A. S. Ilnitskaya and N A Gloushankova and Roman V. Timoshenko and Alexander S. Erofeev and Alexander V. Erofeev and Dmitry V. Shtansky},
title = {Osteoconductive, Osteogenic, and Antipathogenic Plasma Electrolytic Oxidation Coatings on Titanium Implants with BMP-2},
journal = {ACS applied materials & interfaces},
year = {2023},
volume = {15},
publisher = {American Chemical Society (ACS)},
month = {jul},
url = {https://pubs.acs.org/doi/10.1021/acsami.3c08954},
number = {31},
pages = {37274--37289},
doi = {10.1021/acsami.3c08954}
}
MLA
Цитировать
Popova, Anastasiya D., et al. “Osteoconductive, Osteogenic, and Antipathogenic Plasma Electrolytic Oxidation Coatings on Titanium Implants with BMP-2.” ACS applied materials & interfaces, vol. 15, no. 31, Jul. 2023, pp. 37274-37289. https://pubs.acs.org/doi/10.1021/acsami.3c08954.
Ошибка в публикации?