Accurate and 30-plus days reliable cuffless blood pressure measurements with 9-minutes personal photoplethysmograph data and mixed deduction learning

Bitewulign Kassa Mekonnen 1
Wei‑Ru Lu 1
Tung‑Han Hsieh 1
Justin Chu 1
Fu-Liang Yang 1
Publication typeJournal Article
Publication date2024-10-10
scimago Q1
wos Q1
SJR0.874
CiteScore6.7
Impact factor3.9
ISSN20452322
Abstract
Cuffless blood pressure (BP) measurements have long been anticipated, and the PPG (Photoplethysmography)-only method is the most promising one since already embedded in many wearable devices. To further meet the clinical accuracy requirements, PPG-only BP predictions with personalized modeling for overcoming personal deviations have been widely studied, but all required tens to hundreds of minutes of personal PPG measurements for training. Moreover, their accurate test periods without calibration practice were not reported. In this work, we collected records of PPG data from our recruited subjects in real-life scenarios instead of relying on the openly available MIMIC dataset obtained from intensive care unit (ICU) patients. Since our objective is commercial application and a substantial reduction in training data, we tailored our model training to closely mimic real-world usage. To achieve this, we developed a training approach that only requires 9-minutes of personal PPG signal recordings and mixed with other PPG data from our recruited 364 subjects. The modeling is conducted with two-channel paired inputs to the convolutional neural network (CNN)-based model, which we called Mixed Deduction Learning (MDL). The test results of 88 samples from 15 subjects, under testing period up to 30-plus days without extra calibration, revealed that MDL meets most of the standards of AAMI, BHS, and IEEE 1708–2014 (for static test only) for BP measurement devices, which indicates MDL’s long-term stability and consistency. Furthermore, we found that the model with two-channel inputs presents a trend of improving performance as the pool of mixed training data increased, while the conventional one-channel input revealed degraded performance. The outperformance of MDL is attributed to many significant features remained in the first CNN layer even when mixing personal 9-minutes data with the other 364 subjects. Consequently, PPG-only with MDL introduces a new avenue for overcoming challenges in training due to personal physiological variations. Given our consideration of real-life usage, this technology can be seamlessly translated to commercial applications.
Found 
Found 

Top-30

Publishers

1
Institute of Electrical and Electronics Engineers (IEEE)
1 publication, 100%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
1
Share
Cite this
GOST |
Cite this
GOST Copy
Mekonne B. K. et al. Accurate and 30-plus days reliable cuffless blood pressure measurements with 9-minutes personal photoplethysmograph data and mixed deduction learning // Scientific Reports. 2024. Vol. 14. No. 1. 23722
GOST all authors (up to 50) Copy
Mekonnen B. K., Lu W., Hsieh T., Chu J., Fu-Liang Yang Accurate and 30-plus days reliable cuffless blood pressure measurements with 9-minutes personal photoplethysmograph data and mixed deduction learning // Scientific Reports. 2024. Vol. 14. No. 1. 23722
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1038/s41598-024-75583-y
UR - https://www.nature.com/articles/s41598-024-75583-y
TI - Accurate and 30-plus days reliable cuffless blood pressure measurements with 9-minutes personal photoplethysmograph data and mixed deduction learning
T2 - Scientific Reports
AU - Mekonnen, Bitewulign Kassa
AU - Lu, Wei‑Ru
AU - Hsieh, Tung‑Han
AU - Chu, Justin
AU - Fu-Liang Yang
PY - 2024
DA - 2024/10/10
PB - Springer Nature
IS - 1
VL - 14
PMID - 39390076
SN - 2045-2322
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2024_Mekonne,
author = {Bitewulign Kassa Mekonnen and Wei‑Ru Lu and Tung‑Han Hsieh and Justin Chu and Fu-Liang Yang},
title = {Accurate and 30-plus days reliable cuffless blood pressure measurements with 9-minutes personal photoplethysmograph data and mixed deduction learning},
journal = {Scientific Reports},
year = {2024},
volume = {14},
publisher = {Springer Nature},
month = {oct},
url = {https://www.nature.com/articles/s41598-024-75583-y},
number = {1},
pages = {23722},
doi = {10.1038/s41598-024-75583-y}
}