Open Access
Open access
volume 6 issue 1 publication number 233

Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system

Adrián Szobi 1, 2
Katarína Buranovská 1, 2
Nina Vojtaššáková 1, 2
Daniel Lovíšek 1, 2
Halil Önder Özbaşak 1, 2
Sandra Szeibeczederová 1, 2
Liudmyla Kapustian 1, 2
Zuzana Hudáčová 1, 2, 3
Viera Kovacova 1, 2, 4
Diana Drobná 1, 2
Piotr Putaj 1, 2
Stanislava Bírová 1, 2
Ivana Čirková 1, 2
Martin Čarnecký 1, 2
Peter Kilián 1, 2
Peter Jurkáček 5
Viktória Čabanová 6
Kristína Boršová 6
Monika Sláviková 6
Veronika Vaňová 6, 7
Boris Klempa 6, 7
Pavol Cekan 1, 2
E. Paul 1, 2
Publication typeJournal Article
Publication date2023-03-02
scimago Q1
wos Q1
SJR2.071
CiteScore8.8
Impact factor5.1
ISSN23993642
General Biochemistry, Genetics and Molecular Biology
Medicine (miscellaneous)
General Agricultural and Biological Sciences
Abstract

Sensitive and rapid point-of-care assays have been crucial in the global response to SARS-CoV-2. Loop-mediated isothermal amplification (LAMP) has emerged as an important diagnostic tool given its simplicity and minimal equipment requirements, although limitations exist regarding sensitivity and the methods used to detect reaction products. We describe the development of Vivid COVID-19 LAMP, which leverages a metallochromic detection system utilizing zinc ions and a zinc sensor, 5-Br-PAPS, to circumvent the limitations of classic detection systems dependent on pH indicators or magnesium chelators. We make important strides in improving RT-LAMP sensitivity by establishing principles for using LNA-modified LAMP primers, multiplexing, and conducting extensive optimizations of reaction parameters. To enable point-of-care testing, we introduce a rapid sample inactivation procedure without RNA extraction that is compatible with self-collected, non-invasive gargle samples. Our quadruplexed assay (targeting E, N, ORF1a, and RdRP) reliably detects 1 RNA copy/µl of sample (=8 copies/reaction) from extracted RNA and 2 RNA copies/µl of sample (=16 copies/reaction) directly from gargle samples, making it one of the most sensitive RT-LAMP tests and even comparable to RT-qPCR. Additionally, we demonstrate a self-contained, mobile version of our assay in a variety of high-throughput field testing scenarios on nearly 9,000 crude gargle samples. Vivid COVID-19 LAMP can be an important asset for the endemic phase of COVID-19 as well as preparing for future pandemics.

Found 
Found 

Top-30

Journals

1
2
Scientific Reports
2 publications, 14.29%
Analytical Biochemistry
1 publication, 7.14%
Journal of Tropical Medicine
1 publication, 7.14%
Molecular Biology Reports
1 publication, 7.14%
Environmental DNA
1 publication, 7.14%
Methods in Molecular Biology
1 publication, 7.14%
The CRISPR Journal
1 publication, 7.14%
Talanta
1 publication, 7.14%
Journal of Fungi
1 publication, 7.14%
Analytica Chimica Acta
1 publication, 7.14%
Microbial Biotechnology
1 publication, 7.14%
Biosensors
1 publication, 7.14%
Comprehensive Reviews in Food Science and Food Safety
1 publication, 7.14%
1
2

Publishers

1
2
3
4
Springer Nature
4 publications, 28.57%
Elsevier
3 publications, 21.43%
Wiley
3 publications, 21.43%
MDPI
2 publications, 14.29%
Hindawi Limited
1 publication, 7.14%
Mary Ann Liebert
1 publication, 7.14%
1
2
3
4
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
14
Share
Cite this
GOST |
Cite this
GOST Copy
Szobi A. et al. Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system // Communications Biology. 2023. Vol. 6. No. 1. 233
GOST all authors (up to 50) Copy
Szobi A., Buranovská K., Vojtaššáková N., Lovíšek D., Özbaşak H. Ö., Szeibeczederová S., Kapustian L., Hudáčová Z., Kovacova V., Drobná D., Putaj P., Bírová S., Čirková I., Čarnecký M., Kilián P., Jurkáček P., Čabanová V., Boršová K., Sláviková M., Vaňová V., Klempa B., Cekan P., Paul E. Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system // Communications Biology. 2023. Vol. 6. No. 1. 233
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1038/s42003-023-04612-9
UR - https://doi.org/10.1038/s42003-023-04612-9
TI - Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system
T2 - Communications Biology
AU - Szobi, Adrián
AU - Buranovská, Katarína
AU - Vojtaššáková, Nina
AU - Lovíšek, Daniel
AU - Özbaşak, Halil Önder
AU - Szeibeczederová, Sandra
AU - Kapustian, Liudmyla
AU - Hudáčová, Zuzana
AU - Kovacova, Viera
AU - Drobná, Diana
AU - Putaj, Piotr
AU - Bírová, Stanislava
AU - Čirková, Ivana
AU - Čarnecký, Martin
AU - Kilián, Peter
AU - Jurkáček, Peter
AU - Čabanová, Viktória
AU - Boršová, Kristína
AU - Sláviková, Monika
AU - Vaňová, Veronika
AU - Klempa, Boris
AU - Cekan, Pavol
AU - Paul, E.
PY - 2023
DA - 2023/03/02
PB - Springer Nature
IS - 1
VL - 6
PMID - 36864129
SN - 2399-3642
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2023_Szobi,
author = {Adrián Szobi and Katarína Buranovská and Nina Vojtaššáková and Daniel Lovíšek and Halil Önder Özbaşak and Sandra Szeibeczederová and Liudmyla Kapustian and Zuzana Hudáčová and Viera Kovacova and Diana Drobná and Piotr Putaj and Stanislava Bírová and Ivana Čirková and Martin Čarnecký and Peter Kilián and Peter Jurkáček and Viktória Čabanová and Kristína Boršová and Monika Sláviková and Veronika Vaňová and Boris Klempa and Pavol Cekan and E. Paul},
title = {Vivid COVID-19 LAMP is an ultrasensitive, quadruplexed test using LNA-modified primers and a zinc ion and 5-Br-PAPS colorimetric detection system},
journal = {Communications Biology},
year = {2023},
volume = {6},
publisher = {Springer Nature},
month = {mar},
url = {https://doi.org/10.1038/s42003-023-04612-9},
number = {1},
pages = {233},
doi = {10.1038/s42003-023-04612-9}
}
Profiles