volume 121 issue 12 pages 1839-1843

Solid-phase extraction coupled with electrochemical detection for the determination of the herbicide bromofenoxim in water samples at low-and sub-µg l–1levels

Publication typeJournal Article
Publication date1996-01-01
scimago Q2
wos Q2
SJR0.617
CiteScore7.0
Impact factor3.3
ISSN00032654, 13645528, 07417918
PubMed ID:  9008406
Biochemistry
Spectroscopy
Analytical Chemistry
Electrochemistry
Environmental Chemistry
Abstract
The application of solid-phase extraction (SPE) as a preconcentration and clean-up step with subsequent off-line flow injection amperometric (FI-AD) or batch square-wave voltammetric (SWV) detection of the herbicide bromofenoxim was developed. The selection of an appropriate organic eluent, some parameters influencing the efficiency of the SPE and the electrochemical detection of bromofenoxim in the organic effluent solution were thoroughly investigated. Undiluted acetonitrile with SWV and acetonitrile-water (80 + 20) with FI-AD, both containing 0.1 mol l-1 LiClO4, were chosen as the most appropriate SPE eluents. The addition of LiClO4 as supporting electrolyte to the eluent and acidification of a water sample to 1 x 10(-3) mol l-1 HClO4 (pH 3) prior to the SPE procedure were found to improve greatly the current response on mercury drop (SWV) and mercury film (FI-AD) electrodes. Subsequent to the SPE procedure, the effluents were transferred to the voltammetric cell or injected into the flow injection system without any further treatment. The calibration plots obtained for bromofenoxim in pure water samples were linear over the ranges 0.2-12.0 micrograms l-1 and 3.0-120 micrograms l-1, with calculated detection limits of 0.05 and 1.5 micrograms l-1 (100 ml samples), for the SPE-SWV and SPE-FI-AD procedures, respectively. The actual detection capabilities of the proposed methods depend on the water sample volumes applied to the extraction cartridges. The recoveries of the over-all procedures, applying spiked tap water samples, and the corresponding RSDs were 92% and 6% (n = 6) and 121% and 9% (n = 7) for SPE-SWV and SPE-FI-AD, respectively. The practical applicability of the proposed methods for the analysis of ground and tap water samples was confirmed via an inter-laboratory test on a tap water sample containing five common pesticides including bromofenoxim.
Found 
Found 

Top-30

Journals

1
Analytical Chemistry
1 publication, 20%
Electrochemistry Communications
1 publication, 20%
Electroanalysis
1 publication, 20%
Toxicological and Environmental Chemistry
1 publication, 20%
Journal of Agricultural and Food Chemistry
1 publication, 20%
1

Publishers

1
2
American Chemical Society (ACS)
2 publications, 40%
Elsevier
1 publication, 20%
Wiley
1 publication, 20%
Taylor & Francis
1 publication, 20%
1
2
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
5
Share
Cite this
GOST |
Cite this
GOST Copy
Švegl I. G. et al. Solid-phase extraction coupled with electrochemical detection for the determination of the herbicide bromofenoxim in water samples at low-and sub-µg l–1levels // The Analyst. 1996. Vol. 121. No. 12. pp. 1839-1843.
GOST all authors (up to 50) Copy
Švegl I. G., Ogorevc B., Ogorevc B., Novič M., Benfenati E. Solid-phase extraction coupled with electrochemical detection for the determination of the herbicide bromofenoxim in water samples at low-and sub-µg l–1levels // The Analyst. 1996. Vol. 121. No. 12. pp. 1839-1843.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1039/an9962101839
UR - https://doi.org/10.1039/an9962101839
TI - Solid-phase extraction coupled with electrochemical detection for the determination of the herbicide bromofenoxim in water samples at low-and sub-µg l–1levels
T2 - The Analyst
AU - Švegl, Irena Grabec
AU - Ogorevc, Bozidar
AU - Ogorevc, Božidar
AU - Novič, Milko
AU - Benfenati, Emilio
PY - 1996
DA - 1996/01/01
PB - Royal Society of Chemistry (RSC)
SP - 1839-1843
IS - 12
VL - 121
PMID - 9008406
SN - 0003-2654
SN - 1364-5528
SN - 0741-7918
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{1996_Švegl,
author = {Irena Grabec Švegl and Bozidar Ogorevc and Božidar Ogorevc and Milko Novič and Emilio Benfenati},
title = {Solid-phase extraction coupled with electrochemical detection for the determination of the herbicide bromofenoxim in water samples at low-and sub-µg l–1levels},
journal = {The Analyst},
year = {1996},
volume = {121},
publisher = {Royal Society of Chemistry (RSC)},
month = {jan},
url = {https://doi.org/10.1039/an9962101839},
number = {12},
pages = {1839--1843},
doi = {10.1039/an9962101839}
}
MLA
Cite this
MLA Copy
Švegl, Irena Grabec, et al. “Solid-phase extraction coupled with electrochemical detection for the determination of the herbicide bromofenoxim in water samples at low-and sub-µg l–1levels.” The Analyst, vol. 121, no. 12, Jan. 1996, pp. 1839-1843. https://doi.org/10.1039/an9962101839.