том 21 издание 4 страницы 519-533

High Performance Liquid Chromatographic Method for the Assay of Undecylenic Acid and Undecylenates in Pharmaceutical Products After Conversion to 4′-Nitrophenacyl Esters

Cesar Lau-Cam 1
R W Roos 1
1
 
a College of Pharmacy and Allied Health Professions St. John's University , Jamaica, New York, 11439
Тип публикацииJournal Article
Дата публикации1998-02-01
scimago Q3
wos Q4
БС3
SJR0.240
CiteScore2.2
Impact factor1.2
ISSN10826076, 1520572X
Biochemistry
Pharmaceutical Science
Clinical Biochemistry
Analytical Chemistry
Краткое описание
A high performance liquid chromatographic (HPLC) method with spectrophotometric detection is presented for the assay of undecylenic acid, undecylenates (calcium, zinc), and the combination undecylenic acid-zinc undecylenate in commercial antifungal products. To enhance detection, an acetone solution of the sample preparation and sodium octanoate, the internal standard, was derivatized with 4′-nitrophenacyl bromide in the presence of triethylamine at 50°C for 30 min. An aliquot of the reaction mixture was directly analyzed on a Microsorb-MV C8 column, with methanol-acetonitrile-water (50:30:20) as the mobile phase, and detection at 265 nm. At a flow rate of 1.6 mL/min, baseline resolution of the mixture of 4′-nitrophenacyl esters was attained in less than 7 minutes. Detector responses were linearly related to concentrations of reacted undecylenic acid, or its equivalent in an undecylenate, in the range 12.5–300 μg. The recovery of undecylenic acid or an undecylenate from spiked commercial products...
Найдено 
Найдено 

Топ-30

Журналы

1
Journal of Chromatography A
1 публикация, 33.33%
ChemSusChem
1 публикация, 33.33%
Journal of Liquid Chromatography and Related Technologies
1 публикация, 33.33%
1

Издатели

1
Elsevier
1 публикация, 33.33%
Wiley
1 публикация, 33.33%
Taylor & Francis
1 публикация, 33.33%
1
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
3
Поделиться
Цитировать
ГОСТ |
Цитировать
Lau-Cam C., Roos R. W. High Performance Liquid Chromatographic Method for the Assay of Undecylenic Acid and Undecylenates in Pharmaceutical Products After Conversion to 4′-Nitrophenacyl Esters // Journal of Liquid Chromatography and Related Technologies. 1998. Vol. 21. No. 4. pp. 519-533.
ГОСТ со всеми авторами (до 50) Скопировать
Lau-Cam C., Roos R. W. High Performance Liquid Chromatographic Method for the Assay of Undecylenic Acid and Undecylenates in Pharmaceutical Products After Conversion to 4′-Nitrophenacyl Esters // Journal of Liquid Chromatography and Related Technologies. 1998. Vol. 21. No. 4. pp. 519-533.
RIS |
Цитировать
TY - JOUR
DO - 10.1080/10826079808001237
UR - https://doi.org/10.1080/10826079808001237
TI - High Performance Liquid Chromatographic Method for the Assay of Undecylenic Acid and Undecylenates in Pharmaceutical Products After Conversion to 4′-Nitrophenacyl Esters
T2 - Journal of Liquid Chromatography and Related Technologies
AU - Lau-Cam, Cesar
AU - Roos, R W
PY - 1998
DA - 1998/02/01
PB - Taylor & Francis
SP - 519-533
IS - 4
VL - 21
SN - 1082-6076
SN - 1520-572X
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{1998_Lau-Cam,
author = {Cesar Lau-Cam and R W Roos},
title = {High Performance Liquid Chromatographic Method for the Assay of Undecylenic Acid and Undecylenates in Pharmaceutical Products After Conversion to 4′-Nitrophenacyl Esters},
journal = {Journal of Liquid Chromatography and Related Technologies},
year = {1998},
volume = {21},
publisher = {Taylor & Francis},
month = {feb},
url = {https://doi.org/10.1080/10826079808001237},
number = {4},
pages = {519--533},
doi = {10.1080/10826079808001237}
}
MLA
Цитировать
Lau-Cam, Cesar, and R W Roos. “High Performance Liquid Chromatographic Method for the Assay of Undecylenic Acid and Undecylenates in Pharmaceutical Products After Conversion to 4′-Nitrophenacyl Esters.” Journal of Liquid Chromatography and Related Technologies, vol. 21, no. 4, Feb. 1998, pp. 519-533. https://doi.org/10.1080/10826079808001237.