том 30 издание 2 страницы 156-168

Intra and inter-tester reliability of a novel device to assess gluteal muscle strength in professional football players

Víctor Moreno Pérez 1, 2
Marco Beato 3
Juan Del Coso 4
Jose Luis Hernández Davó 1
Aitor Soler 5
Marc Madruga-Parera 6
Daniel Romero-Rodríguez 6
Тип публикацииJournal Article
Дата публикации2020-12-30
scimago Q1
wos Q2
БС1
SJR0.892
CiteScore5.5
Impact factor1.9
ISSN15438627, 15438635
Orthopedics and Sports Medicine
Physical Therapy, Sports Therapy and Rehabilitation
Краткое описание
The aim of this study is to investigate inter-tester and intra-tester reliability of a novel clam test (CLAMT) for the measurement of gluteal muscle strength and to detect possible differences between CLAMT values in football players with and without a history of groin injuries. Twenty male football players participated in the test-retest and sixty-two male professional football players participated in the case-control study. Hip abductor maximal muscle strength was evaluated either using CLAMT or in a supine position with the hip in a neutral pose. For CLAMT, intraclass correlation coefficient (ICC) for inter-tester-intra-day reliability was 0.80 (95% CI: 0.60-0.90), with a standard error of measurement of 34.2 N. The intra-tester-intra-day ICC was 0.92 (95% CI: 0.87-0.95), with a standard error of measurement of 23.6 N. The inter-week ICC was 0.96 (95% CI: 0.92-0.98), with a standard error of measurement of 18.9 N. CLAMT showed lower (but not significant) strength values in football players with a history of groin injuries to non-injured players. CLAMT showed good to excellent levels of reliability, intraday and inter-week, with low standard errors of measurement while it was effective (possible) to identify residual weakness in players with previous groin injuries.
Найдено 
Найдено 

Топ-30

Журналы

1
Journal of Sports Medicine
1 публикация, 25%
Sports Medicine
1 публикация, 25%
Journal of Sport Rehabilitation
1 публикация, 25%
Sports
1 публикация, 25%
1

Издатели

1
Hindawi Limited
1 публикация, 25%
Springer Nature
1 публикация, 25%
Human Kinetics
1 публикация, 25%
MDPI
1 публикация, 25%
1
  • Мы не учитываем публикации, у которых нет DOI.
  • Статистика публикаций обновляется еженедельно.

Вы ученый?

Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
4
Поделиться
Цитировать
ГОСТ |
Цитировать
Moreno Pérez V. et al. Intra and inter-tester reliability of a novel device to assess gluteal muscle strength in professional football players // Research in Sports Medicine. 2020. Vol. 30. No. 2. pp. 156-168.
ГОСТ со всеми авторами (до 50) Скопировать
Moreno Pérez V., Moreno-Pérez V., Beato M., Del Coso J., Hernández Davó J. L., Soler A., Peñaranda-Moraga M., Madruga-Parera M., Romero-Rodríguez D. Intra and inter-tester reliability of a novel device to assess gluteal muscle strength in professional football players // Research in Sports Medicine. 2020. Vol. 30. No. 2. pp. 156-168.
RIS |
Цитировать
TY - JOUR
DO - 10.1080/15438627.2020.1868466
UR - https://doi.org/10.1080/15438627.2020.1868466
TI - Intra and inter-tester reliability of a novel device to assess gluteal muscle strength in professional football players
T2 - Research in Sports Medicine
AU - Moreno Pérez, Víctor
AU - Moreno-Pérez, Victor
AU - Beato, Marco
AU - Del Coso, Juan
AU - Hernández Davó, Jose Luis
AU - Soler, Aitor
AU - Peñaranda-Moraga, Marcelo
AU - Madruga-Parera, Marc
AU - Romero-Rodríguez, Daniel
PY - 2020
DA - 2020/12/30
PB - Taylor & Francis
SP - 156-168
IS - 2
VL - 30
PMID - 33380214
SN - 1543-8627
SN - 1543-8635
ER -
BibTex |
Цитировать
BibTex (до 50 авторов) Скопировать
@article{2020_Moreno Pérez,
author = {Víctor Moreno Pérez and Victor Moreno-Pérez and Marco Beato and Juan Del Coso and Jose Luis Hernández Davó and Aitor Soler and Marcelo Peñaranda-Moraga and Marc Madruga-Parera and Daniel Romero-Rodríguez},
title = {Intra and inter-tester reliability of a novel device to assess gluteal muscle strength in professional football players},
journal = {Research in Sports Medicine},
year = {2020},
volume = {30},
publisher = {Taylor & Francis},
month = {dec},
url = {https://doi.org/10.1080/15438627.2020.1868466},
number = {2},
pages = {156--168},
doi = {10.1080/15438627.2020.1868466}
}
MLA
Цитировать
Moreno Pérez, Víctor, et al. “Intra and inter-tester reliability of a novel device to assess gluteal muscle strength in professional football players.” Research in Sports Medicine, vol. 30, no. 2, Dec. 2020, pp. 156-168. https://doi.org/10.1080/15438627.2020.1868466.