volume 69 issue 18 pages 18NT01

On the implementation of acollinearity in PET Monte Carlo simulations

Maxime Toussaint 1
Francis Loignon Houle 2
Étienne Auger 3
Gabriel Lapointe 4
Jean Pierre Dussault 5
Roger Lecomte 1, 3
1
 
Sherbrooke Molecular Imaging Center of CRCHUS and Department of Nuclear Medicine and Radiobiology, Sherbrooke, Québec, Canada.
3
 
IR&T Inc., Sherbrooke, Québec, Canada.
4
 
Independent researcher, Shefford, Québec, Canada.
Publication typeJournal Article
Publication date2024-09-10
scimago Q1
wos Q1
SJR0.883
CiteScore5.7
Impact factor3.4
ISSN00319155, 13616560
Abstract

Objective. Acollinearity of annihilation photons (APA) introduces spatial blur in positron emission tomography (PET) imaging. This phenomenon increases proportionally with the scanner diameter and it has been shown to follow a Gaussian distribution. This last statement can be interpreted in two ways: the magnitude of the acollinearity angle, or the angular deviation of annihilation photons from perfect collinearity. As the former constitutes the partial integral of the latter, a misinterpretation could have significant consequences on the resulting spatial blurring. Previous research investigating the impact of APA in PET imaging has assumed the Gaussian nature of its angular deviation, which is consistent with experimental results. However, a comprehensive analysis of several simulation software packages for PET data acquisition revealed that the magnitude of APA was implemented as a Gaussian distribution. Approach. We quantified the impact of this misinterpretation of APA by comparing simulations obtained with GATE, which is one of these simulation programs, to an in-house modification of GATE that models APA deviation as following a Gaussian distribution. Main results. We show that the APA misinterpretation not only alters the spatial blurring profile in image space, but also considerably underestimates the impact of APA on spatial resolution. For an ideal PET scanner with a diameter of 81 cm, the APA point source response simulated under the first interpretation has a cusp shape with 0.4 mm FWHM. This is significantly different from the expected Gaussian point source response of 2.1 mm FWHM reproduced under the second interpretation. Significance. Although this misinterpretation has been found in several PET simulation tools, it has had a limited impact on the simulated spatial resolution of current PET scanners due to its small magnitude relative to the other factors. However, the inaccuracy it introduces in estimating the overall spatial resolution of PET scanners will increase as the performance of newer devices improves.

Found 
Found 

Top-30

Journals

1
EJNMMI Physics
1 publication, 50%
Journal of Nuclear Medicine
1 publication, 50%
1

Publishers

1
Springer Nature
1 publication, 50%
Society of Nuclear Medicine
1 publication, 50%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
2
Share
Cite this
GOST |
Cite this
GOST Copy
Toussaint M. et al. On the implementation of acollinearity in PET Monte Carlo simulations // Physics in Medicine and Biology. 2024. Vol. 69. No. 18. p. 18NT01.
GOST all authors (up to 50) Copy
Toussaint M., Loignon Houle F., Auger É., Lapointe G., Dussault J. P., Lecomte R. On the implementation of acollinearity in PET Monte Carlo simulations // Physics in Medicine and Biology. 2024. Vol. 69. No. 18. p. 18NT01.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1088/1361-6560/ad70f1
UR - https://iopscience.iop.org/article/10.1088/1361-6560/ad70f1
TI - On the implementation of acollinearity in PET Monte Carlo simulations
T2 - Physics in Medicine and Biology
AU - Toussaint, Maxime
AU - Loignon Houle, Francis
AU - Auger, Étienne
AU - Lapointe, Gabriel
AU - Dussault, Jean Pierre
AU - Lecomte, Roger
PY - 2024
DA - 2024/09/10
PB - IOP Publishing
SP - 18NT01
IS - 18
VL - 69
PMID - 39159667
SN - 0031-9155
SN - 1361-6560
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2024_Toussaint,
author = {Maxime Toussaint and Francis Loignon Houle and Étienne Auger and Gabriel Lapointe and Jean Pierre Dussault and Roger Lecomte},
title = {On the implementation of acollinearity in PET Monte Carlo simulations},
journal = {Physics in Medicine and Biology},
year = {2024},
volume = {69},
publisher = {IOP Publishing},
month = {sep},
url = {https://iopscience.iop.org/article/10.1088/1361-6560/ad70f1},
number = {18},
pages = {18NT01},
doi = {10.1088/1361-6560/ad70f1}
}
MLA
Cite this
MLA Copy
Toussaint, Maxime, et al. “On the implementation of acollinearity in PET Monte Carlo simulations.” Physics in Medicine and Biology, vol. 69, no. 18, Sep. 2024, p. 18NT01. https://iopscience.iop.org/article/10.1088/1361-6560/ad70f1.