Open Access
Calculation of optimal parameters for F-19 MRI
N Anisimov
1
,
M Gulaev
1
,
Olga S Pavlova
1
,
D Fomina
2, 3, 4
,
V Glukhova
2, 3, 4
,
S Batova
2, 3, 4
,
Yu A Pirogov
2, 3, 4
Publication type: Journal Article
Publication date: 2017-08-29
SJR: 0.187
CiteScore: 1.3
Impact factor: —
ISSN: 17426588, 17426596
General Physics and Astronomy
Abstract
This paper presents a method for optimizing the parameters of the scanning pulse sequences for MRI in relation to objects with a wide NMR spectrum. In this case, a broadband excitation of the spin system is difficult because of hardware limitations. It is proposed to apply the selective excitation, the optimum parameters of which are calculated by an algorithm that uses information concerning the NMR spectrum. The method is especially useful for 19F MRI of fluorocarbons.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
|
|
|
Applied Magnetic Resonance
1 publication, 50%
|
|
|
NeuroImage
1 publication, 50%
|
|
|
1
|
Publishers
|
1
|
|
|
Springer Nature
1 publication, 50%
|
|
|
Elsevier
1 publication, 50%
|
|
|
1
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
2
Total citations:
2
Citations from 2024:
0
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Anisimov N. et al. Calculation of optimal parameters for F-19 MRI // Journal of Physics: Conference Series. 2017. Vol. 886. p. 12001.
GOST all authors (up to 50)
Copy
Anisimov N., Gulaev M., Pavlova O. S., Fomina D., Glukhova V., Batova S., Pirogov Yu. A. Calculation of optimal parameters for F-19 MRI // Journal of Physics: Conference Series. 2017. Vol. 886. p. 12001.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1088/1742-6596/886/1/012001
UR - https://iopscience.iop.org/article/10.1088/1742-6596/886/1/012001
TI - Calculation of optimal parameters for F-19 MRI
T2 - Journal of Physics: Conference Series
AU - Anisimov, N
AU - Gulaev, M
AU - Pavlova, Olga S
AU - Fomina, D
AU - Glukhova, V
AU - Batova, S
AU - Pirogov, Yu A
PY - 2017
DA - 2017/08/29
PB - IOP Publishing
SP - 12001
VL - 886
SN - 1742-6588
SN - 1742-6596
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2017_Anisimov,
author = {N Anisimov and M Gulaev and Olga S Pavlova and D Fomina and V Glukhova and S Batova and Yu A Pirogov},
title = {Calculation of optimal parameters for F-19 MRI},
journal = {Journal of Physics: Conference Series},
year = {2017},
volume = {886},
publisher = {IOP Publishing},
month = {aug},
url = {https://iopscience.iop.org/article/10.1088/1742-6596/886/1/012001},
pages = {12001},
doi = {10.1088/1742-6596/886/1/012001}
}
Profiles