Open Access
Open access
Journal of Physics: Conference Series, volume 886, pages 12001

Calculation of optimal parameters for F-19 MRI

Anisimov N 1
Pavlova O
Pirogov Yu
Gulaev M 1
Fomina D 2, 3, 4
Glukhova V 2, 3, 4
Batova S 2, 3, 4
Pirogov Yu A 2, 3, 4
Publication typeJournal Article
Publication date2017-08-29
Quartile SCImago
Quartile WOS
Impact factor
ISSN17426588, 17426596
General Physics and Astronomy
Abstract
This paper presents a method for optimizing the parameters of the scanning pulse sequences for MRI in relation to objects with a wide NMR spectrum. In this case, a broadband excitation of the spin system is difficult because of hardware limitations. It is proposed to apply the selective excitation, the optimum parameters of which are calculated by an algorithm that uses information concerning the NMR spectrum. The method is especially useful for 19F MRI of fluorocarbons.

Citations by journals

1
Applied Magnetic Resonance
Applied Magnetic Resonance, 1, 50%
Applied Magnetic Resonance
1 publication, 50%
NeuroImage
NeuroImage, 1, 50%
NeuroImage
1 publication, 50%
1

Citations by publishers

1
Springer Nature
Springer Nature, 1, 50%
Springer Nature
1 publication, 50%
Elsevier
Elsevier, 1, 50%
Elsevier
1 publication, 50%
1
  • We do not take into account publications that without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.
Metrics
Share
Cite this
GOST |
Cite this
GOST Copy
Anisimov N. et al. Calculation of optimal parameters for F-19 MRI // Journal of Physics: Conference Series. 2017. Vol. 886. p. 12001.
GOST all authors (up to 50) Copy
Anisimov N., Pavlova O., Pirogov Yu., Gulaev M., Pavlova O. S., Fomina D., Glukhova V., Batova S., Pirogov Yu. A. Calculation of optimal parameters for F-19 MRI // Journal of Physics: Conference Series. 2017. Vol. 886. p. 12001.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1088/1742-6596/886/1/012001
UR - https://doi.org/10.1088%2F1742-6596%2F886%2F1%2F012001
TI - Calculation of optimal parameters for F-19 MRI
T2 - Journal of Physics: Conference Series
AU - Anisimov, N
AU - Gulaev, M
AU - Pavlova, O
AU - Fomina, D
AU - Glukhova, V
AU - Batova, S
AU - Pirogov, Yu
AU - Pavlova, Olga S
AU - Pirogov, Yu A
PY - 2017
DA - 2017/08/29 00:00:00
PB - IOP Publishing
SP - 12001
VL - 886
SN - 1742-6588
SN - 1742-6596
ER -
BibTex
Cite this
BibTex Copy
@article{2017_Anisimov,
author = {N Anisimov and M Gulaev and O Pavlova and D Fomina and V Glukhova and S Batova and Yu Pirogov and Olga S Pavlova and Yu A Pirogov},
title = {Calculation of optimal parameters for F-19 MRI},
journal = {Journal of Physics: Conference Series},
year = {2017},
volume = {886},
publisher = {IOP Publishing},
month = {aug},
url = {https://doi.org/10.1088%2F1742-6596%2F886%2F1%2F012001},
pages = {12001},
doi = {10.1088/1742-6596/886/1/012001}
}
Found error?