volume 30 issue 4

Development of a Modular Cryo-Transfer Station for the Side-Entry Transmission Electron Microscope

Alexander Reifsnyder 1
A. R. Lupini 2
David W. McComb 1, 3
1
 
Department of Materials Science and Engineering, Fontana Laboratories Suite 2136, 140 W. 19th Avenue , Columbus, OH 43210 , USA
3
 
Center for Electron Microscopy and Analysis , 1305 Kinnear Rd Suite 100, Columbus, OH 43212 , USA
Publication typeJournal Article
Publication date2024-08-06
scimago Q2
wos Q1
SJR0.465
CiteScore1.3
Impact factor3.0
ISSN14319276, 14358115
PubMed ID:  39107244
Abstract

Cryo-transfer stations are essential tools in the field of cryo-electron microscopy, enabling the safe transfer of frozen vitreous samples between different stages of the workflow. However, existing cryo-transfer stations are typically configured for only the two most popular sample holder geometries and are not commercially available for all electron microscopes. Additionally, they are expensive and difficult to customize, which limits their accessibility and adaptability for research laboratories. Here, we present a new modular cryo-transfer station that addresses these limitations. The station is composed entirely of 3D-printed and off the shelf parts, allowing it to be reconfigured to a fit variety of microscopes and experimental protocols. We describe the design and construction of the station and report on the results of testing the cryo-transfer station, including its ability to maintain cryogenic temperatures and transfer frozen vitreous samples as demonstrated by vibrational spectroscopy. Our findings demonstrate that the cryo-transfer station performs comparably to existing commercial models, while offering greater accessibility and customizability. The design for the station is open source to encourage other groups to replicate and build on this development. We hope that this project will increase access to cryo-transfer stations for researchers in a variety of disciplines with nonstandard equipment.

Found 
Found 

Top-30

Journals

1
Microscopy and Microanalysis
1 publication, 100%
1

Publishers

1
Oxford University Press
1 publication, 100%
1
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
1
Share
Cite this
GOST |
Cite this
GOST Copy
Reifsnyder A. et al. Development of a Modular Cryo-Transfer Station for the Side-Entry Transmission Electron Microscope // Microscopy and Microanalysis. 2024. Vol. 30. No. 4.
GOST all authors (up to 50) Copy
Reifsnyder A., Hachtel J. A., Lupini A. R., McComb D. W. Development of a Modular Cryo-Transfer Station for the Side-Entry Transmission Electron Microscope // Microscopy and Microanalysis. 2024. Vol. 30. No. 4.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1093/mam/ozae063
UR - https://academic.oup.com/mam/advance-article/doi/10.1093/mam/ozae063/7728379
TI - Development of a Modular Cryo-Transfer Station for the Side-Entry Transmission Electron Microscope
T2 - Microscopy and Microanalysis
AU - Reifsnyder, Alexander
AU - Hachtel, Jordan A.
AU - Lupini, A. R.
AU - McComb, David W.
PY - 2024
DA - 2024/08/06
PB - Oxford University Press
IS - 4
VL - 30
PMID - 39107244
SN - 1431-9276
SN - 1435-8115
ER -
BibTex
Cite this
BibTex (up to 50 authors) Copy
@article{2024_Reifsnyder,
author = {Alexander Reifsnyder and Jordan A. Hachtel and A. R. Lupini and David W. McComb},
title = {Development of a Modular Cryo-Transfer Station for the Side-Entry Transmission Electron Microscope},
journal = {Microscopy and Microanalysis},
year = {2024},
volume = {30},
publisher = {Oxford University Press},
month = {aug},
url = {https://academic.oup.com/mam/advance-article/doi/10.1093/mam/ozae063/7728379},
number = {4},
doi = {10.1093/mam/ozae063}
}
Profiles