Distribution transformer is the most vital component in the power system. Failure of a transformer leads to loss of revenue besides affecting the reliability of power supply to consumers. It can lead to the non-availability of the transformer for a long duration. Due to this, it is important to maintain the good quality of mineral oil. Thus, if the quality of the mineral oil is reduced then its dielectric strength/quality is degraded. Finally, it can affect the services of the transformer, in terms of continuity of power supply. This paper entails the development of a mathematical MATLAB/Simulink model which able to calculate the life cycle of distribution transformer and exact oil changing frequency. With the help of proposed Matlab/Simulink models, the plot curves between furan content formation versus time, pollution index versus time, and dielectric strength of oil versus time are also prepared. The article methodology uses the newly proposed equations, that are in accordance with IEEE standards: IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators (IEEE Std. C57.91-2011) and IEEE Guide for the Reclamation of Insulating Oil and Criteria for Its Use (IEEE Std C57.637-2015). Then the case study for a 100 kVA distribution transformer is realized. So, with the input values in the Simulink model of load current of the transformer, dielectric constant of oil and flash point of oil we can estimate the life of the distribution transformer. Harmonic load factor in our research work is not included, in order to reduce influence of harmonic load we need to installed the active filter, which is not covered in this paper.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
3
|
|
|
IEEE Access
3 publications, 16.67%
|
|
|
Energies
2 publications, 11.11%
|
|
|
Energy Systems
1 publication, 5.56%
|
|
|
Sensors
1 publication, 5.56%
|
|
|
IEEE Transactions on Power Delivery
1 publication, 5.56%
|
|
|
IEEJ Transactions on Electrical and Electronic Engineering
1 publication, 5.56%
|
|
|
Journal of Physics: Conference Series
1 publication, 5.56%
|
|
|
e-Prime - Advances in Electrical Engineering Electronics and Energy
1 publication, 5.56%
|
|
|
Machines
1 publication, 5.56%
|
|
|
IEEE Transactions on Dielectrics and Electrical Insulation
1 publication, 5.56%
|
|
|
Electric Power Systems Research
1 publication, 5.56%
|
|
|
Engineering Applications of Artificial Intelligence
1 publication, 5.56%
|
|
|
1
2
3
|
Publishers
|
1
2
3
4
5
6
7
8
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
8 publications, 44.44%
|
|
|
MDPI
4 publications, 22.22%
|
|
|
Elsevier
3 publications, 16.67%
|
|
|
Springer Nature
1 publication, 5.56%
|
|
|
Wiley
1 publication, 5.56%
|
|
|
IOP Publishing
1 publication, 5.56%
|
|
|
1
2
3
4
5
6
7
8
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
18
Total citations:
18
Citations from 2024:
10
(55.56%)
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Soni R. et al. Estimation of Life Cycle of Distribution Transformer in Context to Furan Content Formation, Pollution Index, and Dielectric Strength // IEEE Access. 2021. Vol. 9. pp. 37456-37465.
GOST all authors (up to 50)
Copy
Soni R., Chakrabarti P., Leonowicz Z., Jasinski M., Wieczorek K., Bolshev V. Estimation of Life Cycle of Distribution Transformer in Context to Furan Content Formation, Pollution Index, and Dielectric Strength // IEEE Access. 2021. Vol. 9. pp. 37456-37465.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1109/access.2021.3063551
UR - https://doi.org/10.1109/access.2021.3063551
TI - Estimation of Life Cycle of Distribution Transformer in Context to Furan Content Formation, Pollution Index, and Dielectric Strength
T2 - IEEE Access
AU - Soni, Rajkumar
AU - Chakrabarti, Prasun
AU - Leonowicz, Zbigniew
AU - Jasinski, Michal
AU - Wieczorek, Krzysztof
AU - Bolshev, Vadim
PY - 2021
DA - 2021/03/04
PB - Institute of Electrical and Electronics Engineers (IEEE)
SP - 37456-37465
VL - 9
SN - 2169-3536
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2021_Soni,
author = {Rajkumar Soni and Prasun Chakrabarti and Zbigniew Leonowicz and Michal Jasinski and Krzysztof Wieczorek and Vadim Bolshev},
title = {Estimation of Life Cycle of Distribution Transformer in Context to Furan Content Formation, Pollution Index, and Dielectric Strength},
journal = {IEEE Access},
year = {2021},
volume = {9},
publisher = {Institute of Electrical and Electronics Engineers (IEEE)},
month = {mar},
url = {https://doi.org/10.1109/access.2021.3063551},
pages = {37456--37465},
doi = {10.1109/access.2021.3063551}
}