The Airborne Reflective/Emissive Spectrometer is specified as a whisk-broom imaging spectrometer for remote sensing of land surfaces covering the wavelength regions 0.47-2.45 μm and 8-12 μm with 160 spectral bands. The instrument is being built by Integrated Spectronics, financed by the German Aerospace Agency (DLR) and the GeoResearch Centre Potsdam (GFZ) and will be available to the scientific community from end 2005 on. The spectroradiometric design is based on scientific requirements derived from three main application scenarios comprising vegetation, soil, and mineral sciences. Two of these are described in this letter. Measured or modeled reflectance spectra are input to a simulation model that calculates at-sensor radiance spectra, resamples them with the channel-specific response functions, adds different amounts of noise in the radiance domain, and performs a retrieval to get the corresponding noisy surface reflectance spectra. The retrieval results as a function of the sensor noise level are compared with the accuracy requirements imposed by the different application fields taking into account the technical boundary conditions. The final specifications account for the most demanding requirements of the three application fields: a spectral sampling distance of 13-14 nm in the 470-1800 nm region, and 12 nm in the 2000-2450-nm region. The required noise-equivalent radiances are 5, 3, and 2 nW/spl middot/cm/sup -2//spl middot/sr/sup -1//spl middot/nm/sup -1/ for the spectral regions 470-1000, 1000-1800, and 2000-2450 nm, respectively.
Found 
Found 

Top-30

Journals

1
2
3
1
2
3

Publishers

1
2
3
1
2
3
  • We do not take into account publications without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Share
Cite this
GOST | RIS | BibTex | MLA
Found error?