Time-Resolved Raman Spectrometer With High Fluorescence Rejection Based on a CMOS SPAD Line Sensor and a 573-nm Pulsed Laser
Tuomo Talala
1
,
Ville A. Kaikkonen
2
,
Pekka Keränen
1
,
J. Nikkinen
3
,
Antti Harkonen
3
,
V.G. Savitski
4
,
Sean Reilly
5
,
Ukasz Dziechciarczyk
5
,
A. E. S. Kemp
5
,
Mircea Guina
3
,
A. Mäkynen
2
,
Ilkka Nissinen
1
Publication type: Journal Article
Publication date: 2021-01-26
scimago Q1
wos Q1
SJR: 1.471
CiteScore: 10.1
Impact factor: 5.9
ISSN: 00189456, 15579662
Electrical and Electronic Engineering
Instrumentation
Abstract
A time-resolved Raman spectrometer is demonstrated based on a 256 × 8 single-photon avalanche diodes fabricated in CMOS technology (CMOS SPAD) line sensor and a 573-nm fiber-coupled diamond Raman laser delivering pulses with duration below 100-ps full-width at half-maximum (FWHM). The collected backscattered light from the sample is dispersed on the line sensor using a custom volume holographic grating having 1800 lines/mm. Efficient fluorescence rejection in the Raman measurements is achieved due to a combination of time gating on sub-100-ps time scale and a 573-nm excitation wavelength. To demonstrate the performance of the spectrometer, fluorescent oil samples were measured. For organic sesame seed oil having a continuous wave (CW) mode fluorescence-to-Raman ratio of 10.5 and a fluorescence lifetime of 2.7 ns, a signal-to-distortion value of 76.2 was achieved. For roasted sesame seed oil having a CW mode fluorescence-to-Raman ratio of 82 and a fluorescence lifetime of 2.2 ns, a signal-to-distortion value of 28.2 was achieved. In both cases, the fluorescence-to-Raman ratio was reduced by a factor of 24-25 owing to time gating. For organic oil, spectral distortion was dominated by dark counts, while for the more fluorescent roasted oil, the main source of spectral distortion was timing skew of the sensor. With the presented postprocessing techniques, the level of distortion could be reduced by 88%-89% for both samples. Compared with common 532-nm excitation, approximately 73% lower fluorescence-to-Raman ratio was observed for 573-nm excitation when analyzing the organic sesame seed oil.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
2
3
4
5
6
7
8
|
|
|
IEEE Transactions on Instrumentation and Measurement
8 publications, 29.63%
|
|
|
Optics Letters
2 publications, 7.41%
|
|
|
Sensors
2 publications, 7.41%
|
|
|
Talanta Open
1 publication, 3.7%
|
|
|
Measurement: Journal of the International Measurement Confederation
1 publication, 3.7%
|
|
|
ACS applied materials & interfaces
1 publication, 3.7%
|
|
|
IEEE Journal of Solid-State Circuits
1 publication, 3.7%
|
|
|
IEEE Instrumentation and Measurement Magazine
1 publication, 3.7%
|
|
|
Catalysis Science and Technology
1 publication, 3.7%
|
|
|
Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy
1 publication, 3.7%
|
|
|
Optics Express
1 publication, 3.7%
|
|
|
Analytical Sciences
1 publication, 3.7%
|
|
|
Biomedical Optics Express
1 publication, 3.7%
|
|
|
Microchemical Journal
1 publication, 3.7%
|
|
|
Food Chemistry
1 publication, 3.7%
|
|
|
Applied Spectroscopy
1 publication, 3.7%
|
|
|
1
2
3
4
5
6
7
8
|
Publishers
|
2
4
6
8
10
12
|
|
|
Institute of Electrical and Electronics Engineers (IEEE)
11 publications, 40.74%
|
|
|
Elsevier
6 publications, 22.22%
|
|
|
Optica Publishing Group
4 publications, 14.81%
|
|
|
MDPI
2 publications, 7.41%
|
|
|
American Chemical Society (ACS)
1 publication, 3.7%
|
|
|
Royal Society of Chemistry (RSC)
1 publication, 3.7%
|
|
|
Springer Nature
1 publication, 3.7%
|
|
|
SAGE
1 publication, 3.7%
|
|
|
2
4
6
8
10
12
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
27
Total citations:
27
Citations from 2024:
15
(55.56%)
The most citing journal
Citations in journal:
8
Cite this
GOST |
RIS |
BibTex
Cite this
GOST
Copy
Talala T. et al. Time-Resolved Raman Spectrometer With High Fluorescence Rejection Based on a CMOS SPAD Line Sensor and a 573-nm Pulsed Laser // IEEE Transactions on Instrumentation and Measurement. 2021. Vol. 70. pp. 1-10.
GOST all authors (up to 50)
Copy
Talala T., Kaikkonen V. A., Keränen P., Nikkinen J., Harkonen A., Savitski V., Reilly S., Dziechciarczyk U., Kemp A. E. S., Guina M., Mäkynen A., Nissinen I. Time-Resolved Raman Spectrometer With High Fluorescence Rejection Based on a CMOS SPAD Line Sensor and a 573-nm Pulsed Laser // IEEE Transactions on Instrumentation and Measurement. 2021. Vol. 70. pp. 1-10.
Cite this
RIS
Copy
TY - JOUR
DO - 10.1109/tim.2021.3054679
UR - https://doi.org/10.1109/tim.2021.3054679
TI - Time-Resolved Raman Spectrometer With High Fluorescence Rejection Based on a CMOS SPAD Line Sensor and a 573-nm Pulsed Laser
T2 - IEEE Transactions on Instrumentation and Measurement
AU - Talala, Tuomo
AU - Kaikkonen, Ville A.
AU - Keränen, Pekka
AU - Nikkinen, J.
AU - Harkonen, Antti
AU - Savitski, V.G.
AU - Reilly, Sean
AU - Dziechciarczyk, Ukasz
AU - Kemp, A. E. S.
AU - Guina, Mircea
AU - Mäkynen, A.
AU - Nissinen, Ilkka
PY - 2021
DA - 2021/01/26
PB - Institute of Electrical and Electronics Engineers (IEEE)
SP - 1-10
VL - 70
SN - 0018-9456
SN - 1557-9662
ER -
Cite this
BibTex (up to 50 authors)
Copy
@article{2021_Talala,
author = {Tuomo Talala and Ville A. Kaikkonen and Pekka Keränen and J. Nikkinen and Antti Harkonen and V.G. Savitski and Sean Reilly and Ukasz Dziechciarczyk and A. E. S. Kemp and Mircea Guina and A. Mäkynen and Ilkka Nissinen},
title = {Time-Resolved Raman Spectrometer With High Fluorescence Rejection Based on a CMOS SPAD Line Sensor and a 573-nm Pulsed Laser},
journal = {IEEE Transactions on Instrumentation and Measurement},
year = {2021},
volume = {70},
publisher = {Institute of Electrical and Electronics Engineers (IEEE)},
month = {jan},
url = {https://doi.org/10.1109/tim.2021.3054679},
pages = {1--10},
doi = {10.1109/tim.2021.3054679}
}