IEEE Transactions on Instrumentation and Measurement, volume 70, pages 1-8
Ultrahigh Sensitivity Fiber-Optic Fabry–Perot Interferometric Acoustic Sensor Based on Silicon Cantilever
Min Guo
1
,
Ke Chen
1
,
Beilei Yang
1
,
Chenyang Li
1
,
Bo Zhang
1
,
Yang Yang
1
,
Ya Wang
1
,
Chenxi Li
1
,
Zhenfeng Gong
1
,
Fengxiang Ma
2
,
Qingxu Yu
1
2
Electric Power Research Institute, State Grid Anhui Electric Power Company, Ltd, Hefei, Anhui, China
|
Publication type: Journal Article
Publication date: 2021-08-02
scimago Q1
SJR: 1.536
CiteScore: 9.0
Impact factor: 5.6
ISSN: 00189456, 15579662
Electrical and Electronic Engineering
Instrumentation
Abstract
Detection of weak acoustic signals is of great significance. To achieve ultrahigh sensitivity acoustic detection, a silicon cantilever-based fiber-optic acoustic sensor (FOAS) formed by a Fabry–Perot interferometric structure is proposed in this work. Theoretical analysis and finite element analysis are used to assist the sensor design. The cantilever is fabricated by the microelectro-mechanical system (MEMS) processing technology on a silicon-on-insulator (SOI) wafer. A white light interference (WLI) demodulation system based on an amplified spontaneous emission (ASE) source is used to demodulate the cavity length of the sensor. The acoustic pressure sensitivity of the sensor was measured to be
$1.753~\mu \text{m}$
/Pa at a frequency of 1 kHz and
$28.75~\mu \text{m}$
/Pa at the resonance frequency of the cantilever. Experimental results indicated that the minimum detectable pressure (MDP) level of the fabricated sensor was
$0.21~\mu $
Pa/Hz
1/2
at 1 kHz, which is the lowest reported value. The silicon-based FOAS proposed in this article demonstrates its ability to detect ultraweak acoustic signals due to its extremely high sensitivity.
Found