Optical fine-needle aspiration biopsy in a rat model

Kozlov Igor 1
Alekseyev Alexander 1
Kuznetsov Sergey 2
Mamoshin Andrian 1, 3
Publication typeProceedings Article
Publication date2019-03-01
Quartile SCImago
Quartile WOS
Impact factor
ISSN16057422
Abstract
Fine needle aspiration biopsy technique and following histological examination show its effectiveness and safety but its performing takes several time. However, the problem of real-time analysis of pathological changes in tissues remains relevant. We demonstrate optical fine-needle biopsy method, combining a fine needle (17.5G) and a fiber-optic probe (1 mm diameter) for minimally invasive interrogation of tissue in vivo. During rat tumor experiment, we collected spectrally-resolved diffuse reflectance and fluorescence. Quantified differences between tumor and normal tissues were demonstrated and approved with morphological analysis. The proposed methodology seems promising for developing new diagnostic criteria for clinical practice.

Citations by journals

1
Biomedical Optics Express
Biomedical Optics Express, 1, 25%
Biomedical Optics Express
1 publication, 25%
Optics and Spectroscopy (English translation of Optika i Spektroskopiya)
Optics and Spectroscopy (English translation of Optika i Spektroskopiya), 1, 25%
Optics and Spectroscopy (English translation of Optika i Spektroskopiya)
1 publication, 25%
1

Citations by publishers

1
Optical Society of America
Optical Society of America, 1, 25%
Optical Society of America
1 publication, 25%
Pleiades Publishing
Pleiades Publishing, 1, 25%
Pleiades Publishing
1 publication, 25%
1
  • We do not take into account publications that without a DOI.
  • Statistics recalculated only for publications connected to researchers, organizations and labs registered on the platform.
  • Statistics recalculated weekly.
Metrics
Share
Cite this
GOST |
Cite this
GOST Copy
Potapova E. et al. Optical fine-needle aspiration biopsy in a rat model // Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2019. Vol. 10877.
GOST all authors (up to 50) Copy
Potapova E., Zherebtsov E., Kozlov I., Seryogina E., Kandurova K., Alekseyev A., Kuznetsov S., Mamoshin A., Dunaev A. Optical fine-needle aspiration biopsy in a rat model // Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2019. Vol. 10877.
RIS |
Cite this
RIS Copy
TY - CPAPER
DO - 10.1117/12.2509255
UR - https://doi.org/10.1117%2F12.2509255
TI - Optical fine-needle aspiration biopsy in a rat model
T2 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
AU - Potapova, Elena
AU - Zherebtsov, Evgeny
AU - Kozlov, Igor
AU - Seryogina, Evgeniya
AU - Kandurova, Ksenia
AU - Alekseyev, Alexander
AU - Kuznetsov, Sergey
AU - Mamoshin, Andrian
AU - Dunaev, Andrey
PY - 2019
DA - 2019/03/01 00:00:00
PB - SPIE
VL - 10877
SN - 1605-7422
ER -
BibTex
Cite this
BibTex Copy
@inproceedings{2019_Potapova,
author = {Elena Potapova and Evgeny Zherebtsov and Igor Kozlov and Evgeniya Seryogina and Ksenia Kandurova and Alexander Alekseyev and Sergey Kuznetsov and Andrian Mamoshin and Andrey Dunaev},
title = {Optical fine-needle aspiration biopsy in a rat model},
year = {2019},
volume = {10877},
month = {mar},
publisher = {SPIE}
}
Found error?