Wearable sensor system for multipoint measurements of blood perfusion: Pilot studies in patients with diabetes mellitus
Elena V Zharkikh
2
,
Igor O Kozlov
2
,
Angelina I. Zherebtsova
2
,
Ilya E. Rafailov
3
,
Sergei G Sokolovski
4
,
Victor V. Sidorov
5
,
Andrey V. Dunaev
2
,
Edik U Rafailov
4
3
Aston Medical Technology Ltd., Birmingham, UK
|
5
SPE ”LAZMA” Ltd, Moscow, Russia
|
Publication type: Proceedings Article
Publication date: 2019-07-22
Abstract
The growing interest in the development of new wearable electronic devices for mobile healthcare provides great opportunities for the development of methods for assessing blood perfusion in this direction. Laser Doppler flowmetry (LDF) is one of the promising methods. A fine analysis of capillary blood ow structure and rhythm in the time and frequency domains, coupled with a new possibility of round-the-clock monitoring can provide valuable diagnostic information about the state of microvascular blood ow. In this study, wearable implementation of laser Doppler flowmetry was utilised for microcirculatory function assessment in patients with diabetes and healthy controls of two distinct age groups. Four wearable laser Doppler flowmetry monitors were used for the analysis of blood microcirculation. Thirty-seven healthy volunteers and 18 patients with type 2 diabetes mellitus participated in the study. The results of the studies have shown that the average perfusion differs between healthy volunteers of distinct age groups and between healthy volunteers of the younger age group and patients with diabetes mellitus. It was noted that the average level of perfusion measured on the wrist in the two groups of healthy volunteers has no statistically significant differences found in similar measurements on the fingertips. The wearable implementation of LDF can become a truly new diagnostic interface to monitor cardiovascular parameters, which could be of interest for diagnostics of conditions associated with microvascular disorders.
Found
Nothing found, try to update filter.
Found
Nothing found, try to update filter.
Top-30
Journals
|
1
|
|
|
Bio-Medical Engineering
1 publication, 14.29%
|
|
|
Diagnostics
1 publication, 14.29%
|
|
|
Human Physiology
1 publication, 14.29%
|
|
|
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
1 publication, 14.29%
|
|
|
Regional blood circulation and microcirculation
1 publication, 14.29%
|
|
|
1
|
Publishers
|
1
2
|
|
|
SPIE-Intl Soc Optical Eng
2 publications, 28.57%
|
|
|
Springer Nature
1 publication, 14.29%
|
|
|
MDPI
1 publication, 14.29%
|
|
|
Pleiades Publishing
1 publication, 14.29%
|
|
|
JMIR Publications
1 publication, 14.29%
|
|
|
FSBEI HE I.P. Pavlov SPbSMU MOH Russia
1 publication, 14.29%
|
|
|
1
2
|
- We do not take into account publications without a DOI.
- Statistics recalculated weekly.
Are you a researcher?
Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
7
Total citations:
7
Citations from 2025:
0