Open Access
Optical fine needle biopsy in hepatocellular carcinoma mouse model
Elena V Potapova
1
,
Evgenii A Zherebtsov
1, 2
,
Alexander G Alekseyev
1
,
Andrian V Mamoshin
1, 3
,
Yuri Ivanov
4, 5
,
Dmitry Panchenkov
6
,
2
Univ. of Oulu (Finland)
|
3
Orel Regional Clinical Hospital (Russian Federation)
|
4
Central Research Institute of Tuberculosis (Russian Federation)
|
5
Federal Scientific and Clinical Ctr. for Specialized Medical Service and Medical Technologies (Russian Federation)
|
Тип публикации: Proceedings Article
Дата публикации: 2020-04-02
SJR: 0.146
CiteScore: 0.5
Impact factor: —
ISSN: 0277786X, 1996756X
Краткое описание
The paper describes the results of experimental studies using custom developed optical biopsy system for diagnostics in vivo during the procedure of fine needle aspiration biopsy. Experimental studies were conducted in laboratory mice with inoculated hepatocellular carcinoma. The measurements were carried out using fluorescence spectroscopy and diffuse reflectance spectroscopy methods to reveal metabolic and morphological changes in tissues. The results show that the developed approach is sensitive for cancer detection. Quantified differences in the maximum of fluorescence spectra and diffuse reflectance spectra between tumor and normal tissues were demonstrated and approved with morphological analysis.
Найдено
Ничего не найдено, попробуйте изменить настройки фильтра.
Топ-30
Журналы
|
1
|
|
|
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
1 публикация, 100%
|
|
|
1
|
Издатели
|
1
|
|
|
SPIE-Intl Soc Optical Eng
1 публикация, 100%
|
|
|
1
|
- Мы не учитываем публикации, у которых нет DOI.
- Статистика публикаций обновляется еженедельно.
Вы ученый?
Создайте профиль, чтобы получать персональные рекомендации коллег, конференций и новых статей.
Метрики
1
Всего цитирований:
1
Цитирований c 2024:
0
Самый цитирующий журнал
Цитирований в журнале:
1
Цитировать
ГОСТ |
RIS |
BibTex
Цитировать
ГОСТ
Скопировать
Potapova E. V. et al. Optical fine needle biopsy in hepatocellular carcinoma mouse model // Proceedings of SPIE - The International Society for Optical Engineering. 2020. Vol. 11363. p. 32.
ГОСТ со всеми авторами (до 50)
Скопировать
Potapova E. V., Kandurova K. Y., Shupletsov V. V., Seryogina E., Zherebtsov E. A., Alekseyev A. G., Mamoshin A. V., Ivanov Y., Panchenkov D., Dunaev A. V. Optical fine needle biopsy in hepatocellular carcinoma mouse model // Proceedings of SPIE - The International Society for Optical Engineering. 2020. Vol. 11363. p. 32.
Цитировать
RIS
Скопировать
TY - CPAPER
DO - 10.1117/12.2555154
UR - https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11363/2555154/Optical-fine-needle-biopsy-in-hepatocellular-carcinoma-mouse-model/10.1117/12.2555154.full
TI - Optical fine needle biopsy in hepatocellular carcinoma mouse model
T2 - Proceedings of SPIE - The International Society for Optical Engineering
AU - Potapova, Elena V
AU - Kandurova, Ksenia Y
AU - Shupletsov, Valery V
AU - Seryogina, Evgeniya
AU - Zherebtsov, Evgenii A
AU - Alekseyev, Alexander G
AU - Mamoshin, Andrian V
AU - Ivanov, Yuri
AU - Panchenkov, Dmitry
AU - Dunaev, Andrey V.
PY - 2020
DA - 2020/04/02
PB - SPIE-Intl Soc Optical Eng
SP - 32
VL - 11363
SN - 0277-786X
SN - 1996-756X
ER -
Цитировать
BibTex (до 50 авторов)
Скопировать
@inproceedings{2020_Potapova,
author = {Elena V Potapova and Ksenia Y Kandurova and Valery V Shupletsov and Evgeniya Seryogina and Evgenii A Zherebtsov and Alexander G Alekseyev and Andrian V Mamoshin and Yuri Ivanov and Dmitry Panchenkov and Andrey V. Dunaev},
title = {Optical fine needle biopsy in hepatocellular carcinoma mouse model},
year = {2020},
volume = {11363},
pages = {32},
month = {apr},
publisher = {SPIE-Intl Soc Optical Eng}
}