volume 53 issue 5 pages 770-776

A closed-cycle cryostat for optical and Mössbauer spectroscopy in the temperature range 4.2-300 K

Publication typeJournal Article
Publication date2010-09-01
scimago Q4
wos Q4
SJR0.234
CiteScore0.9
Impact factor0.4
ISSN00204412, 16083180
Instrumentation
Abstract
A closed cycle cryostat intended for optical and Mössbauer investigations in the temperature range 4.2–300 K is described. Samples are cooled owing to the operation of a two-stage closed-cycle cryogenic refrigerator (CR) based on the Gifford-MacMahon cycle (with a refrigerating capacity of 1 W at T = 4.2 K at the second stage). The minimum temperature reached at the second stage of the CR was 2.7 K. The methods for reducing vibrations transferred from the CR to a sample are described in detail. The design proposed makes it possible to reduce the vibrational broadening of the resonance Mössbauer lines to a level of 10–15% at 5 K, thus exceeding the level of the best cryostat prototypes in the world.
Found 
Found 

Top-30

Journals

1
2
3
4
Acta Crystallographica Section B: Structural Science, Crystal Engineering and Materials
4 publications, 14.81%
Journal of Alloys and Compounds
4 publications, 14.81%
Physical Review B
2 publications, 7.41%
JETP Letters
2 publications, 7.41%
Instruments and Experimental Techniques
2 publications, 7.41%
Beilstein Journal of Nanotechnology
1 publication, 3.7%
Physical Chemistry Chemical Physics
1 publication, 3.7%
Dalton Transactions
1 publication, 3.7%
Pharmaceutics
1 publication, 3.7%
Materials Science and Engineering C
1 publication, 3.7%
Smart Materials and Structures
1 publication, 3.7%
Crystals
1 publication, 3.7%
Micromachines
1 publication, 3.7%
Europhysics Letters
1 publication, 3.7%
Journal of Magnetism and Magnetic Materials
1 publication, 3.7%
Carbon
1 publication, 3.7%
IEEE Transactions on Applied Superconductivity
1 publication, 3.7%
Thermal Science and Engineering Progress
1 publication, 3.7%
1
2
3
4

Publishers

1
2
3
4
5
6
7
8
Elsevier
8 publications, 29.63%
Pleiades Publishing
4 publications, 14.81%
International Union of Crystallography (IUCr)
4 publications, 14.81%
MDPI
3 publications, 11.11%
American Physical Society (APS)
2 publications, 7.41%
Royal Society of Chemistry (RSC)
2 publications, 7.41%
IOP Publishing
2 publications, 7.41%
Beilstein-Institut
1 publication, 3.7%
Institute of Electrical and Electronics Engineers (IEEE)
1 publication, 3.7%
1
2
3
4
5
6
7
8
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
27
Share
Cite this
GOST |
Cite this
GOST Copy
NAUMOV P. et al. A closed-cycle cryostat for optical and Mössbauer spectroscopy in the temperature range 4.2-300 K // Instruments and Experimental Techniques. 2010. Vol. 53. No. 5. pp. 770-776.
GOST all authors (up to 50) Copy
NAUMOV P., Lyubutin I. S., Frolov K., Demikhov E. I. A closed-cycle cryostat for optical and Mössbauer spectroscopy in the temperature range 4.2-300 K // Instruments and Experimental Techniques. 2010. Vol. 53. No. 5. pp. 770-776.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1134/S0020441210050301
UR - https://doi.org/10.1134/S0020441210050301
TI - A closed-cycle cryostat for optical and Mössbauer spectroscopy in the temperature range 4.2-300 K
T2 - Instruments and Experimental Techniques
AU - NAUMOV, P.G.
AU - Lyubutin, I S
AU - Frolov, K.V.
AU - Demikhov, E. I.
PY - 2010
DA - 2010/09/01
PB - Pleiades Publishing
SP - 770-776
IS - 5
VL - 53
SN - 0020-4412
SN - 1608-3180
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2010_NAUMOV,
author = {P.G. NAUMOV and I S Lyubutin and K.V. Frolov and E. I. Demikhov},
title = {A closed-cycle cryostat for optical and Mössbauer spectroscopy in the temperature range 4.2-300 K},
journal = {Instruments and Experimental Techniques},
year = {2010},
volume = {53},
publisher = {Pleiades Publishing},
month = {sep},
url = {https://doi.org/10.1134/S0020441210050301},
number = {5},
pages = {770--776},
doi = {10.1134/S0020441210050301}
}
MLA
Cite this
MLA Copy
NAUMOV, P.G., et al. “A closed-cycle cryostat for optical and Mössbauer spectroscopy in the temperature range 4.2-300 K.” Instruments and Experimental Techniques, vol. 53, no. 5, Sep. 2010, pp. 770-776. https://doi.org/10.1134/S0020441210050301.