volume 75 issue 8 pages 1072-1079

Potentiometric Sensors Based on Nafion Membranes Modified by PEDOT for Determining Procaine, Lidocaine, and Bupivacaine in Aqueous Solutions and Pharmaceuticals

Publication typeJournal Article
Publication date2020-07-31
scimago Q3
wos Q4
SJR0.252
CiteScore1.9
Impact factor1.1
ISSN10619348, 16083199
Analytical Chemistry
Abstract
Hybrid materials based on perfluorinated sulfonic acid Nafion-type membranes and poly-3,4-ethylenedioxythiophene (PEDOT) with a gradient distribution of the latter along the film length were synthesized by in situ oxidative polymerization. The initial monomer concentration (0.01 and 0.002 M) and the concentration ratio of the monomer to the oxidant (1/1.25 and 1/2.5) were varied. We studied the effect of the equilibrium and transport properties of the obtained materials on the characteristics of cross-sensitive DP-sensors (analytical signal is the Donnan potential) in aqueous solutions of procaine, lidocaine, and bupivacaine hydrochlorides, including those containing sodium chloride, in a concentration range from 1.0 × 10–4 to 1.0 × 10–2 M and pH from 2 to 6. The relative error in determining the active substance in the Novokain preparation using a DP-sensor based on the Nafion/PEDOT membrane (0.002 M, 1/2.5) was 0.4%. An array of DP-sensors based on Nafion and Nafion/PEDOT (0.002 M, 1/1.25) membranes was used to determine bupivacaine hydrochloride and sodium chloride in the Markain® Spinal preparation with an error of 11 and 6%, respectively.
Found 
Found 

Top-30

Journals

1
Talanta
1 publication, 14.29%
Polymers
1 publication, 14.29%
Membranes and Membrane Technologies
1 publication, 14.29%
Journal of Analytical Chemistry
1 publication, 14.29%
Analytical Biochemistry
1 publication, 14.29%
Journal of Solid State Electrochemistry
1 publication, 14.29%
Future Journal of Pharmaceutical Sciences
1 publication, 14.29%
1

Publishers

1
2
Elsevier
2 publications, 28.57%
Pleiades Publishing
2 publications, 28.57%
Springer Nature
2 publications, 28.57%
MDPI
1 publication, 14.29%
1
2
  • We do not take into account publications without a DOI.
  • Statistics recalculated weekly.

Are you a researcher?

Create a profile to get free access to personal recommendations for colleagues and new articles.
Metrics
7
Share
Cite this
GOST |
Cite this
GOST Copy
Titova T. S. et al. Potentiometric Sensors Based on Nafion Membranes Modified by PEDOT for Determining Procaine, Lidocaine, and Bupivacaine in Aqueous Solutions and Pharmaceuticals // Journal of Analytical Chemistry. 2020. Vol. 75. No. 8. pp. 1072-1079.
GOST all authors (up to 50) Copy
Titova T. S., Yurova P. A., Kolganova T. S., Stenina I. A., Parshina A. V., Bobreshova O. V., Yaroslavtsev A. B. Potentiometric Sensors Based on Nafion Membranes Modified by PEDOT for Determining Procaine, Lidocaine, and Bupivacaine in Aqueous Solutions and Pharmaceuticals // Journal of Analytical Chemistry. 2020. Vol. 75. No. 8. pp. 1072-1079.
RIS |
Cite this
RIS Copy
TY - JOUR
DO - 10.1134/S106193482008016X
UR - https://doi.org/10.1134/S106193482008016X
TI - Potentiometric Sensors Based on Nafion Membranes Modified by PEDOT for Determining Procaine, Lidocaine, and Bupivacaine in Aqueous Solutions and Pharmaceuticals
T2 - Journal of Analytical Chemistry
AU - Titova, T S
AU - Yurova, P A
AU - Kolganova, T S
AU - Stenina, I A
AU - Parshina, A V
AU - Bobreshova, O V
AU - Yaroslavtsev, A. B.
PY - 2020
DA - 2020/07/31
PB - Pleiades Publishing
SP - 1072-1079
IS - 8
VL - 75
SN - 1061-9348
SN - 1608-3199
ER -
BibTex |
Cite this
BibTex (up to 50 authors) Copy
@article{2020_Titova,
author = {T S Titova and P A Yurova and T S Kolganova and I A Stenina and A V Parshina and O V Bobreshova and A. B. Yaroslavtsev},
title = {Potentiometric Sensors Based on Nafion Membranes Modified by PEDOT for Determining Procaine, Lidocaine, and Bupivacaine in Aqueous Solutions and Pharmaceuticals},
journal = {Journal of Analytical Chemistry},
year = {2020},
volume = {75},
publisher = {Pleiades Publishing},
month = {jul},
url = {https://doi.org/10.1134/S106193482008016X},
number = {8},
pages = {1072--1079},
doi = {10.1134/S106193482008016X}
}
MLA
Cite this
MLA Copy
Titova, T. S., et al. “Potentiometric Sensors Based on Nafion Membranes Modified by PEDOT for Determining Procaine, Lidocaine, and Bupivacaine in Aqueous Solutions and Pharmaceuticals.” Journal of Analytical Chemistry, vol. 75, no. 8, Jul. 2020, pp. 1072-1079. https://doi.org/10.1134/S106193482008016X.